Dell POWER EDGE SC1430 Hardware Owner's Manual page 62

Server system
Hide thumbs Also See for POWER EDGE SC1430:
Table of Contents

Advertisement

Figure 3-15. Connecting the Cooling Fan for an Optional Fourth Hard Drive
1
1
card fan
15 Check all cable connections, and fold cables out of the way to allow for airflow between the fan and
cooling vents.
16 Reinstall the front drive bezel. See "Removing and Replacing the Front Drive Bezel" on page 46.
17 Ensure that all connectors are properly cabled and firmly seated.
18 Close the system. See "Closing the System" on page 43.
19 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
See the documentation that came with the drive for instructions on installing any software required for
drive operation.
20 Enter the System Setup program (see "Entering the System Setup Program" on page 27), and ensure
that the drive's controller is enabled.
NOTICE:
If the fan cable from the optional hard-drive carrier is not correctly connected to the FAN_HDD
connector on the system board and detected by the system BIOS, premature drive failure can occur.
21 Verify that the Optional Hard-Disk Drive field in System Setup displays Installed. See "Integrated
Devices Screen" on page 32.
22 Exit the System Setup program, and reboot the system.
62
Installing System Components
2
2
fan power cable
3
3
FAN_HDD connector

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents