KitchenAid KECD806RSS04 Installation Instructions Manual
KitchenAid KECD806RSS04 Installation Instructions Manual

KitchenAid KECD806RSS04 Installation Instructions Manual

30" and 36" electric built-in ceramic downdraft cooktop
Hide thumbs Also See for KECD806RSS04:

Advertisement

Quick Links

ui
C
Read and save these
IMPORTANT:
Installer:
Leave HnstaHation
Hnstructions with the homeowner.
Homeowner:
Keep hstaHation
Hnstructions for future reference.
Save hstaHation
hstructions
for HocaH
eHectricaH inspector's
use.
Write down the modeHand seriaHnumbers
before installing cooktop.
Both numbers are on the modeH/seriaH
rating pilate, Hocatedon the bottom of the
cooktop.
ModeH#
Serial #
Part No. 8286553

Advertisement

loading

Summary of Contents for KitchenAid KECD806RSS04

  • Page 1 Read and save these Write down the modeHand seriaHnumbers before installing cooktop. IMPORTANT: Both numbers are on the modeH/seriaH Installer: Leave HnstaHation rating pilate, Hocatedon the bottom of the Hnstructions with the homeowner. cooktop. Homeowner: Keep hstaHation Hnstructions for future reference. ModeH# Save hstaHation hstructions...
  • Page 2: Toolsand Materials Neededfor Installation

    Before you start... Important: Observe aH governing Your safety and the safety of WARNING: To reduce the risk of fire, codes and ordhances. Failure to meet others is very important. electric shock, or injury to persons, codes and ordinances could lead to observe the following:...
  • Page 3 Cateut #imensiens Product #[mens[ens _pth 2-15/16" j (74.6 mml burner box depth coontertop 15-5/8" (3&6 cm) blower housing 34t. 91.4 cm long depth power suppy cab e 5" (12.7 em) factory installed. _estall rear wall junction Clearance gimensiens box ie shaded area.
  • Page 4: Venting Methods

    Ventingsystemrequirements The blower housing is set to vent Venting system must terminate to the Do Not exhaust more than one outside. straight out the back from the cooktop. To downdraft cooktop into a single vent vent down, left or right, see "installation," system.
  • Page 5 Determine equivalent length of vent. Maximum 6" (15.2 era) reund metal vent equivalent length of vent is 60 ft (18.3 m). List the number of each piece and length of straight vent you will use. Multiply the equivalent length by the number of pieces. Add the totals to get the total equivalent length of your system.
  • Page 6 supply is required on a separate The recommended minimum copper 30-ampere circuit, fused on both sides wire size is No.-lO gauge. However, of the line. wire sizes and connections must conform A time-delay fuse or circuit breaker is to the requirements of the National recommended.
  • Page 7 I For all cooktop models with three-wire cable from the cooktop: Where tocal codes Do Not permit connecting the frame- Where Jocal codes permit connecting the frame-ground ground conductor to the neutral (white) junction box conductor to the neutral (white) junction box wire.
  • Page 8: Check Operation

    5. Separate the factory-crimped bare and Check operation For all cooktop models with four- white cooktop cable wires. wire cable from the cooktop. 6, Connect the two white wires together (:These cooktops using twist-on connectors. Turn on electrical supply. manufactured with white 7, Connect the bare ground wire from the (neutra 0 power...
  • Page 9 NOTES...
  • Page 10 NOTES...