Watts ENWARE ENM5072-250 Installation And Maintenance Instructions Manual
Watts ENWARE ENM5072-250 Installation And Maintenance Instructions Manual

Watts ENWARE ENM5072-250 Installation And Maintenance Instructions Manual

Wall mounted sensor tap - on/ off demand sensor

Advertisement

Quick Links

KITB02 consists of:
ENM5072-250
KOL911600-100
KOL97101
KOL15600
Wall Mounted Sensor Tap
Enware D-Shape Basin 600mm
Shroud for D-Shape Basin
Standard P-Trap - 40mm

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ENWARE ENM5072-250 and is the answer not in the manual?

Questions and answers

Summary of Contents for Watts ENWARE ENM5072-250

  • Page 1 KITB02 consists of: ENM5072-250 Wall Mounted Sensor Tap KOL911600-100 Enware D-Shape Basin 600mm KOL97101 Shroud for D-Shape Basin KOL15600 Standard P-Trap - 40mm...
  • Page 2: Installation And Maintenance Instructions

    Wall Mounted Sensor Tap - On/ Off Demand Sensor Installation and Maintenance Instructions ENM5072A-205 EMM5072A-250 I00316_29 Feb 2024 1300 369 273 | info@enware.com.au | enware.com.au...
  • Page 3: Technical Data

    technical data Inlet Connection 15mm (1/2” BSP) Recommended Working Pressure Range 100 - 500 kPa Flow Rate 5 L/min (6 Star WELS rating) (Laminar flow aerator supplied standard with spout) Maximum Hot Water Supply Temperature 70 °C Operating Voltage 24V DC Maximum Current Power Consumption Less than 10W...
  • Page 4: Product Description

    product description Enware Touch-Free Wall Sensor Tap is a sensor operated, hands-free tap that is installed onto walls above sinks, basins or wash troughs. It operates by sensing a hand in front of the sensor unit. Once the sensor is activated, the valve will remain open and water will flow until the hand is again placed in front of the sensor, closing the solenoid valve.
  • Page 5: Before Installation

    before installation LOCATION OF SENSOR When selecting a location to install the wall-mounted sensor, consider the following: Obstructions Reflections And Lighting Ensure that nothing is within range of the sensor. If the sensor unit is installed into a location where Any obstruction directly in front of, and within a nearby wall or object is reflecting the Infrared possible range of, the sensor can trigger the...
  • Page 6: Water Supply Temperature

    SET-OUT HEIGHT - FLOW PATTERN Water Pressure: 350kPa Also take into consideration the water flow projection from spout outlet. Flow Rate: 5 L/min 230mm Spout 205mm Spout Water Flow Projection Water Pressure: 350kPa Flow Rate: 5 L/min 230mm Spout 205mm Spout ACCESS TO SENSOR TAP COMPONENTS BEFORE CONNECTING WATER SUPPLY Ensure that access to the sensor, solenoid valve,...
  • Page 7 installation - IN-WALL POWER SUPPLY INSTALL CONDUIT TO ALLOW FOR FUTURE SERVICING OF CABLES UNION TYPE CONNECTION ISOLATION VALVE AND MESH STRAINER (NOT SUPPLIED) INSTALLATION LAYOUT EXAMPLE IMAGE 01 www.enware.com.au Page 6 © Enware Pty Ltd...
  • Page 8: Solenoid Installation

    SENSOR BRACKET INSTALLATION Once the position of the spout and sensor plate is determined, fix the sensor mounting bracket inside wall. Take note of the maximum and minimum depths for the sensor. Minimum wall depth 66mm, maximum 78mm. SEE IMAGE 01 & 02 IMAGE 02 SOLENOID INSTALLATION The solenoid valve is installed into the water supply line...
  • Page 9 Connect Transformer Cable to Sensor Connector Cable. Connect Solenoid Cable to Sensor Connector Cable Connect cable plug to the terminals on solenoid. (Note: HEX NUT Earth terminal on top is not used.) When connecting cable plug to the solenoid, note that the black casing for solenoid can be turned around to suit the direction of wiring connection, by first loosening the hex nut on top.
  • Page 10 installation - FRONT-OF-WALL INSTALLING THE SPOUT Dismantle Spout Connector from chrome spout. APPLY To do this, take out Grub Screw from the bottom THREAD TAPE of spout, then loosely fit the tail (1/2" all thread) onto Spout Connector, then pull the tail to take out the Spout Connector.
  • Page 11: To Turn Off

    operating instructions TO TURN ON 0.5 sec Place hand in front of sensor lens for half a second at a distance of 5 cm. Move hand away. Water starts to flow. 5 cm TO TURN OFF Place hand in front of sensor lens for half a second at a distance of 5 cm.
  • Page 12: Troubleshooting

    troubleshooting PROBLEM CAUSE RECTIFICATION Tap/ water continues to Solenoid valve is installed Re install valve correctly. Check flow the wrong way round the direction of water flow is with arrow. SEE IMAGE 03 Tap does not turn off Debris in solenoid valve Take solenoid apart and clean diaphragm.
  • Page 13: Spare Parts

    spare parts PART ENWARE PRODUCT CODE Sensor – On / Off Demand ENMS134A (Stainless steel plate, sensor connector cable) Solenoid 1/2” – DC 24v (includes DC solenoid 1/2”, WMS8200S 2x 1/2” nipples) Solenoid Service Kit - DC (includes diaphragm, piston and spring to suit DC WMS8302 solenoid 1/2”) Transformer –...
  • Page 14: Service And Maintenance

    service & maintenance CLEANING Enware products should be cleaned with a soft damp cloth using only mild liquid detergent or soap and water. Do not use cleaning agents containing a corrosive acid, scouring agent or solvent chemicals. Do not use cream cleaners, as they are abrasive. Use of unsuitable cleaning agents may damage the surface.
  • Page 15 SOLENOID MAINTENANCE HEX NUT For long periods of non-use, a minimum activation of 1-2 times per day is recommended. High frequency of use and high water supply pressures reduce the service life of a solenoid. If the solenoid is not working correctly or is leaking, go through the following steps to service the solenoid.
  • Page 16 5. Note the small hole in the rubber diaphragm. It is HOLE important that this hole is clear and not obstructed by debris. Clean the diaphragm by rinsing with water. SEE IMAGE 15 6. Replace any component that is damaged. (Service Kit code WMS8302) 7.
  • Page 17: Product Warranty Statement

    - WATTS AUSTRALIA EFFECTIVE FROM 20 November 2023 3. Our responsibilities This Warranty Statement applies to products supplied by Australian Valve (a) In the event that the Supplier is reasonably satisfied that there is a Group Pty Ltd (ACN 068 227 270) (AVG) or Enware Pty Ltd (ACN 662...
  • Page 18: Installation Instructions

    Enware D-Shape Basin 600mm Installation Instructions KOL911602 KOL911600-100 KOL911602-100 KOL91160222 KOL91160222-100 Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and AS/NZS3500. Installations not complying with PCA and AS/NZS 3500 may void the product and performance warranty provisions. Reference should also be made to the Australasian Health Facility Guidelines (AHFG), ABCB and Local Government regulations when considering the choice of, and the installation of these products.
  • Page 19: Installation

    INSTALLATION Ensure there is adequate wall structure and suitable reinforcement behind finished wall for basin fixings at the required height position. Prepare water and waste outlet points according to the plumbing setouts (refer to setout diagrams). Position the basin onto wall, level, and mark anchor holes. Pre-drill anchor holes where marked, and install fixing bolts.
  • Page 20 STANDARD P-TRAP MICROTRAP SET OUT SET OUT Standard P-Trap (Optional) Microtrap Chrome Code: KOL15600 With Plug & Grate Standard Plug and Waste (supplied) (Optional) Code: IFO14934 Code: IFO15916 Shroud (Optional) With Pop Up (Optional) Code: KOL97100 Code: IFO15917 DN40 DWV PVC outlet for Standard P-Trap KOL15600 (not supplied) with...
  • Page 21 - WATTS AUSTRALIA EFFECTIVE FROM 20 November 2023 3. Our responsibilities This Warranty Statement applies to products supplied by Australian Valve (a) In the event that the Supplier is reasonably satisfied that there is a Group Pty Ltd (ACN 068 227 270) (AVG) or Enware Pty Ltd (ACN 662...
  • Page 22 Shroud for Enware D-Shape 500mm & 600mm Basins Installation Instructions KOL97101 240 ± 10 210 ± 10 Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and AS/NZS3500. Installations not complying with PCA and AS/NZS 3500 may void the product and performance warranty provisions. Reference should also be made to the Australasian Health Facility Guidelines (AHFG), ABCB and Local Government regulations when considering the choice of, and the installation of these products.
  • Page 23 INSTALLATION Ensure there is adequate wall structure and suitable reinforcement behind finished wall for basin and shroud fixings at the required height position. After basin has been installed, position shroud under the lip on the underside of the basin. Mark the anchor holes on the wall. Pre-drill anchor holes where marked. Mount the shroud and install using fixing screws supplied.
  • Page 24 SHROUD FIXING KIT www.enware.com.au Page 3 © Enware Pty Ltd...
  • Page 25 - WATTS AUSTRALIA EFFECTIVE FROM 20 November 2023 3. Our responsibilities This Warranty Statement applies to products supplied by Australian Valve (a) In the event that the Supplier is reasonably satisfied that there is a Group Pty Ltd (ACN 068 227 270) (AVG) or Enware Pty Ltd (ACN 662...

Table of Contents