150mm basin set with fixed spout - jumper valve (8 pages)
Summary of Contents for Watts ENWARE Wellbeing KITB03
Page 1
KITB03 consists of: WLC150WS Leva 150mm Wall Mounted Mixing Set KOL911600-100 Enware D-Shape Basin 600mm KOL97101 Shroud for D-Shape Basin KOL15600 Standard P-Trap - 40mm...
Page 2
Wellbeing Leva 150mm Wall Mounted Mixing ® Set with Straight Spout & Isolation Valves Installation and Maintenance Instructions WLC150WS technical data Working Pressure Range Min 50 kPa Max 500 kPa Maximum Static Pressure 800 kPa Maximum Working 85°C (Ceramic disc) Temperature Inlet Connection 1/2”...
installation • All supply lines must be flushed thoroughly to remove debris prior to the installation of this product. Strainers (40 mesh) are recommended if debris is an ongoing problem. 1/2” BSP 1/2” • A pressure reduction valve may be required to comply with the recommended maximum supply pressure and/or 1/2”...
Page 5
10. Fit spline adaptor [8] onto spindle. Fit tooth washer [7] and washer [6], and fix in place using screw [5]. SEE IMAGE 06 11. Fit colour indicator ring [4] onto lever handle [3]. To do this, place an indicator ring on flat surface with the rebated edge facing up.
maintenance CLEAN AERATOR Clean aerator [12] periodically. Unscrew the aerator using aerator key [13], and rinse it under running water. CLEANING Enware products should be cleaned with a soft damp cloth using only mild liquid detergent or soap and water. Do not use cleaning agents containing a corrosive acid, scouring agent or solvent chemicals.
Page 7
spare parts DESCRIPTION PART CODE Lever handle 150mm Parts: [1] [2] [3] [4 -red,yellow,blue] [5] [6] [7] [8] WLCS-150378 Colour indicators Parts: [4 -red,yellow,blue] LEV398 SBA cold - RTC (Clockwise to close) Parts: [5] [6] [7] [10] WLCS380RTC SBA hot - LTC (Anti-clockwise to close) Parts: [5] [6] [7] [9] WLCS380LTC Spline adaptor Parts: [8] LEVSQHEX...
- WATTS AUSTRALIA Effective 27 October 2023 3. Our responsibilities This Warranty Statement applies to products supplied by Australian Valve (a) In the event that the Supplier is reasonably satisfied that there is a Group Pty Ltd (ACN 068 227 270) (AVG) or Enware Pty Ltd (ACN 662...
Enware D-Shape Basin 600mm Installation Instructions KOL911602 KOL911600-100 KOL911602-100 KOL91160222 KOL91160222-100 Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and AS/NZS3500. Installations not complying with PCA and AS/NZS 3500 may void the product and performance warranty provisions. Reference should also be made to the Australasian Health Facility Guidelines (AHFG), ABCB and Local Government regulations when considering the choice of, and the installation of these products.
Page 11
INSTALLATION Ensure there is adequate wall structure and suitable reinforcement behind finished wall for basin fixings at the required height position. Prepare water and waste outlet points according to the plumbing setouts (refer to setout diagrams). Position the basin onto wall, level, and mark anchor holes. Pre-drill anchor holes where marked, and install fixing bolts.
Page 12
STANDARD P-TRAP MICROTRAP SET OUT SET OUT Standard P-Trap (Optional) Microtrap Chrome Code: KOL15600 With Plug & Grate Standard Plug and Waste (supplied) (Optional) Code: IFO14934 Code: IFO15916 Shroud (Optional) With Pop Up (Optional) Code: KOL97100 Code: IFO15917 DN40 DWV PVC outlet for Standard P-Trap KOL15600 (not supplied) with...
Page 13
- WATTS AUSTRALIA EFFECTIVE FROM 20 November 2023 3. Our responsibilities This Warranty Statement applies to products supplied by Australian Valve (a) In the event that the Supplier is reasonably satisfied that there is a Group Pty Ltd (ACN 068 227 270) (AVG) or Enware Pty Ltd (ACN 662...
Page 14
Shroud for Enware D-Shape 500mm & 600mm Basins Installation Instructions KOL97101 240 ± 10 210 ± 10 Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and AS/NZS3500. Installations not complying with PCA and AS/NZS 3500 may void the product and performance warranty provisions. Reference should also be made to the Australasian Health Facility Guidelines (AHFG), ABCB and Local Government regulations when considering the choice of, and the installation of these products.
Page 15
INSTALLATION Ensure there is adequate wall structure and suitable reinforcement behind finished wall for basin and shroud fixings at the required height position. After basin has been installed, position shroud under the lip on the underside of the basin. Mark the anchor holes on the wall. Pre-drill anchor holes where marked. Mount the shroud and install using fixing screws supplied.
Page 17
- WATTS AUSTRALIA EFFECTIVE FROM 20 November 2023 3. Our responsibilities This Warranty Statement applies to products supplied by Australian Valve (a) In the event that the Supplier is reasonably satisfied that there is a Group Pty Ltd (ACN 068 227 270) (AVG) or Enware Pty Ltd (ACN 662...
Need help?
Do you have a question about the ENWARE Wellbeing KITB03 and is the answer not in the manual?
Questions and answers