Download Print this page
Watts ENWARE Wellbeing KITB03 Installation And Maintenance Instructions Manual
Watts ENWARE Wellbeing KITB03 Installation And Maintenance Instructions Manual

Watts ENWARE Wellbeing KITB03 Installation And Maintenance Instructions Manual

Leva 150mm wall mounted mixing set with straight spout & isolation valves

Advertisement

Quick Links

KITB03 consists of:
WLC150WS
KOL911600-100
KOL97101
KOL15600
Leva 150mm Wall Mounted Mixing Set
Enware D-Shape Basin 600mm
Shroud for D-Shape Basin
Standard P-Trap - 40mm

Advertisement

loading
Need help?

Need help?

Do you have a question about the ENWARE Wellbeing KITB03 and is the answer not in the manual?

Questions and answers

Summary of Contents for Watts ENWARE Wellbeing KITB03

  • Page 1 KITB03 consists of: WLC150WS Leva 150mm Wall Mounted Mixing Set KOL911600-100 Enware D-Shape Basin 600mm KOL97101 Shroud for D-Shape Basin KOL15600 Standard P-Trap - 40mm...
  • Page 2 Wellbeing Leva 150mm Wall Mounted Mixing ® Set with Straight Spout & Isolation Valves Installation and Maintenance Instructions WLC150WS technical data Working Pressure Range Min 50 kPa Max 500 kPa Maximum Static Pressure 800 kPa Maximum Working 85°C (Ceramic disc) Temperature Inlet Connection 1/2”...
  • Page 3 Handle plug 11 Spout Grub screw M5 12 Aerator Laminar 5lpm Cache TT Lever handle 150mm 13 Aerator key Cache TT Colour indicator ring (red/ yellow/ blue) 14 O-ring BS113 Screw M5x20 15 Frame T56 Washer (Nylon) 16 Wall connector with isolation valve Tooth washer M5 17 Dress ring...
  • Page 4: Installation

    installation • All supply lines must be flushed thoroughly to remove debris prior to the installation of this product. Strainers (40 mesh) are recommended if debris is an ongoing problem. 1/2” BSP 1/2” • A pressure reduction valve may be required to comply with the recommended maximum supply pressure and/or 1/2”...
  • Page 5 10. Fit spline adaptor [8] onto spindle. Fit tooth washer [7] and washer [6], and fix in place using screw [5]. SEE IMAGE 06 11. Fit colour indicator ring [4] onto lever handle [3]. To do this, place an indicator ring on flat surface with the rebated edge facing up.
  • Page 6: Troubleshooting

    maintenance CLEAN AERATOR Clean aerator [12] periodically. Unscrew the aerator using aerator key [13], and rinse it under running water. CLEANING Enware products should be cleaned with a soft damp cloth using only mild liquid detergent or soap and water. Do not use cleaning agents containing a corrosive acid, scouring agent or solvent chemicals.
  • Page 7 spare parts DESCRIPTION PART CODE Lever handle 150mm Parts: [1] [2] [3] [4 -red,yellow,blue] [5] [6] [7] [8] WLCS-150378 Colour indicators Parts: [4 -red,yellow,blue] LEV398 SBA cold - RTC (Clockwise to close) Parts: [5] [6] [7] [10] WLCS380RTC SBA hot - LTC (Anti-clockwise to close) Parts: [5] [6] [7] [9] WLCS380LTC Spline adaptor Parts: [8] LEVSQHEX...
  • Page 8 dimensions ISOLATION VALVE 1/2" BSP FEMALE Water Flow Projection WLC150WS Flow Rate: 5 L/min Laminar 500kPa 350kPa 150kPa All measurements are in millimetres. www.enware.com.au Page 7 © Enware Pty Ltd...
  • Page 9: Product Warranty Statement

    - WATTS AUSTRALIA Effective 27 October 2023 3. Our responsibilities This Warranty Statement applies to products supplied by Australian Valve (a) In the event that the Supplier is reasonably satisfied that there is a Group Pty Ltd (ACN 068 227 270) (AVG) or Enware Pty Ltd (ACN 662...
  • Page 10: Installation Instructions

    Enware D-Shape Basin 600mm Installation Instructions KOL911602 KOL911600-100 KOL911602-100 KOL91160222 KOL91160222-100 Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and AS/NZS3500. Installations not complying with PCA and AS/NZS 3500 may void the product and performance warranty provisions. Reference should also be made to the Australasian Health Facility Guidelines (AHFG), ABCB and Local Government regulations when considering the choice of, and the installation of these products.
  • Page 11 INSTALLATION Ensure there is adequate wall structure and suitable reinforcement behind finished wall for basin fixings at the required height position. Prepare water and waste outlet points according to the plumbing setouts (refer to setout diagrams). Position the basin onto wall, level, and mark anchor holes. Pre-drill anchor holes where marked, and install fixing bolts.
  • Page 12 STANDARD P-TRAP MICROTRAP SET OUT SET OUT Standard P-Trap (Optional) Microtrap Chrome Code: KOL15600 With Plug & Grate Standard Plug and Waste (supplied) (Optional) Code: IFO14934 Code: IFO15916 Shroud (Optional) With Pop Up (Optional) Code: KOL97100 Code: IFO15917 DN40 DWV PVC outlet for Standard P-Trap KOL15600 (not supplied) with...
  • Page 13 - WATTS AUSTRALIA EFFECTIVE FROM 20 November 2023 3. Our responsibilities This Warranty Statement applies to products supplied by Australian Valve (a) In the event that the Supplier is reasonably satisfied that there is a Group Pty Ltd (ACN 068 227 270) (AVG) or Enware Pty Ltd (ACN 662...
  • Page 14 Shroud for Enware D-Shape 500mm & 600mm Basins Installation Instructions KOL97101 240 ± 10 210 ± 10 Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and AS/NZS3500. Installations not complying with PCA and AS/NZS 3500 may void the product and performance warranty provisions. Reference should also be made to the Australasian Health Facility Guidelines (AHFG), ABCB and Local Government regulations when considering the choice of, and the installation of these products.
  • Page 15 INSTALLATION Ensure there is adequate wall structure and suitable reinforcement behind finished wall for basin and shroud fixings at the required height position. After basin has been installed, position shroud under the lip on the underside of the basin. Mark the anchor holes on the wall. Pre-drill anchor holes where marked. Mount the shroud and install using fixing screws supplied.
  • Page 16 SHROUD FIXING KIT www.enware.com.au Page 3 © Enware Pty Ltd...
  • Page 17 - WATTS AUSTRALIA EFFECTIVE FROM 20 November 2023 3. Our responsibilities This Warranty Statement applies to products supplied by Australian Valve (a) In the event that the Supplier is reasonably satisfied that there is a Group Pty Ltd (ACN 068 227 270) (AVG) or Enware Pty Ltd (ACN 662...