Page 10
Safety Requirement If you suspect that any damage may occur to the instrument, have it inspected by RIGOL authorized personnel before further operations. Any maintenance, adjustment or replacement especially to circuits or accessories must be performed by RIGOL authorized personnel.
This manual gives you a quick overview of the front and rear panels, user interface as well as basic operation methods of DG800 Pro series function/arbitrary waveform generator. www.rigol.com For the latest version of this manual, download it from RIGOL official website ( Publication Number UGB14101-1110 Software Version 00.02.00...
The consigner or carrier shall be liable for the damage to the instrument resulting from shipment. RIGOL would not be responsible for free maintenance/rework or replacement of the instrument. 2. Inspect the instrument In case of any mechanical damage, missing parts, or failure in passing the electrical and mechanical tests, contact your RIGOL sales representative.
Output USB PD 15 V, 3 A, 45 W CAUTION The power adaptor provided in accessories can only be used to power RIGOL instruments. Do not use it for mobile phone and other devices. WARNING To avoid electric shock, please ensure that the instrument is correctly grounded.
1. Obtain an option license http://www.rigol.com a. Log in to the RIGOL official website ( ), click SERVICE CENTRE > License Activation to enter the software license registration; b. In the software license registration interface, input the correct key, serial number (click or tap >...
You can edit the Arb waveform through the PC software and download it into the instrument. It is recommended to use the PC software Ultra Station provided by RIGOL. The installation package and help manual of the software can be obtained from RIGOL official website.
DG800 Pro supports the Channel Copy function between two channels, allowing you to copy the states of one channel to the other one. DG821 Pro should have the two- channel upgrade option installed. The copy information is as shown in the table below.
The offset voltage remains unchanged when the waveform is inverted. Channel Track DG800 Pro supports the channel track function (DG821 Pro should have the two- channel upgrade option installed). When the Track function for the specified channel Table 11.1 Dual-channel...
Coupling Setup Coupling Setup DG800 Pro supports frequency, amplitude, and phase coupling. DG821 Pro should have the two-channel upgrade option installed. Click or tap > Coupling to enter the "Coupling" menu. In the "Coupling" menu, the Cpl Base displays the base channel for coupling. It is the currently selected channel.
Align Phase Align Phase DG800 Pro provides the Align Phase function. DG821 Pro should have the two- channel upgrade option installed. When the output mode is set to Continuous (except noise and DC), Sweep mode (internal trigger), or Burst mode (internal trigger), click or tap the Align Phase key at the bottom.
After restarting the instrument, insert the USB storage device again to check whether it can work normally. d. If the USB storage device still cannot work normally, please contact RIGOL. 4. Performance verification test is failed. a. Check whether the generator is within calibration period (1 year).