RS21110 USER MANUAL
RS2110
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RS2110 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FS RS2110

  • Page 1 RS21110 USER MANUAL RS2110 User Manual...
  • Page 2: Table Of Contents

    1.7 Connecting Peripheral Devices ......................3 1.8 Turning on monitors and servers ......................3 2. Description of the System Architecture ......................4 2.1 RS2110 structural characteristics ......................4 2.2 Server Rear Window I/O Schematic ......................6 3. System description and setup ........................8 3.1 CPU ..............................
  • Page 3: User Manual

    RS21110 USER MANUAL 1. Preparation for use 1.1 Summary The main task of this chapter is to describe how to do some basic preparations. They include: Check the transportation packaging; Choose a suitable location to place the server; Check the power setting switch; Check the power cord;...
  • Page 4: Installation Of Servers In Racks

    RS21110 USER MANUAL Isolation from Servers should be isolated from strong electromagnetic fields and electromagnetic fields and electrical noise-generating equipment, including elevators, copiers, air electrical noise conditioners, high-powered fans, high-powered motors, radio and environments television transmitters, and high-frequency alerting equipment. Maintain good ventilation The perimeter of the server should ensure good ventilation and cooling and cooling conditions...
  • Page 5: Additional Equipment

    RS21110 USER MANUAL Power cord required descriptive speed The AC curr ent that the wir es ca n tran smi t sh o ul d be rate d at 125 % of the amo unt of cur ren t req ui re d by the serv er. diti Connect to power outlet The cord must have a male plug with a grounded end type.
  • Page 6: Description Of The System Architecture

    If there is a fault, record the error message displayed on the screen and the audible code heard, see: System Troubleshooting chapter. Description of the System Architecture 2.1 RS2110 structural characteristics Front Schematic: Figure 2-1 Front View of the RS2110 Server Front Panel Schematic:...
  • Page 7 RS21110 USER MANUAL Figure 2-2 RS2110 Server Front Panel Diagram ID key 2, 3 USB3.0 warning light hard disk light system status light Network Port Indicator boot key System indicator: Name (of a thing) Color State of affairs Clarification Network 1...
  • Page 8: Server Rear Window I/O Schematic

    RS21110 USER MANUAL Power supply: Power source 300W Full Voltage Range Adaptive Server Professional Power Supply AC Voltage/Frequency 115V/60Hz, 230V /50Hz adaptive Chassis Shape: Profile System Rackmount 1U your (honorific) 43.5mm surname Kuan 438.5mm elder 547.6mm Weight (minimum Approx. 10 KG configuration) 2.2 Server Rear Window I/O Schematic description...
  • Page 9 RS21110 USER MANUAL USB3.0 Portx2 DP Port UID LED Server Rear Window I/O Schematic Rear Window IO Description: Serial port for COM interface devices IPMI interface, IPMI2.0 interface, can be connected to the network cable, through IPMI this interface to monitor and manage the server USB2.0/3.0 interface, can be connected to USB keyboard and mouse, U disk and other USB2.0/3.0 devices...
  • Page 10: System Description And Setup

    RS21110 USER MANUAL 3. System description and setup 3.1 CPU 3.1.1 CPU Overview Intel® Single socket H4 (LGA 1151) supports Intel® Xeon® processor E-2100/2200, Intel® 8th/9th Gen. Core™ i3/I5/I7/I9 series, Intel® Celeron® and Intel® Pentium® 3.1.2 Installation Procedure Description: 1.Install the motherboard into the chassis; 2.Open the retaining wrench for the CPU slot and install the CPU correctly into the slot on the motherboard following the indicated arrows to secure the wrench;...
  • Page 11: Motherboard Structure Diagram

    RS21110 USER MANUAL 3.2 Motherboard Structure Diagram 3.3 random access memory (RAM) 3.3.1 Memory Overview The server has 4 memory slots with expandable capacity up to 512GB; it supports DDR4 2666MT/s ECC unbuffered memory and one CPU supports dual-channel read technology. 3.4 Video Controller The motherboard integrates the AST2500 display chip, which connects to the monitor via a VGA port.
  • Page 12: Hard Disk Controllers

    RS21110 USER MANUAL 3.5 Hard disk controllers The Intel C246 PCH supports 8 SATA 3.0 hard disks. 3.6 Network Controller Two integrated high-performance Gigabit NICs (Intel® I210 GbE chips) provide high-speed network connectivity . 3.7 Keyboard and mouse The keyboard and mouse controller supports USB compatible keyboards and mice. 3.8 Optical and Floppy Drives The server is configured with 1 optional SATA optical drive, optional USB optical drive and floppy drive emulation disk.
  • Page 13: Integrated Raid Configuration

    RS21110 USER MANUAL Red Hat Enterprise Linux* 7U5 64bit 4. Integrated RAID Configuration This chapter introduces the use of motherboard integrated SATA RAID controller to create RAID1, RAID0 and RAID10, RAID1 after the creation of the hard disk capacity is only half of the total capacity of the hard disk to form a backup, the reliability of a lot of improvement.
  • Page 14 RS21110 USER MANUAL 4.2.2 To create an array, select the Create RAID Volume option and the following menu appears:...
  • Page 15 RS21110 USER MANUAL Press < ↑>,< ↓> to move the cursor up and down, and select the level of array you want to create at RAID Level, the options are RAID0, RAID1 and RAID5. After selecting the array level and the hard disks to be arrayed, tap Create Volume Options Select 'Y' as prompted to create the array.
  • Page 16: Operating System Installation Instructions

    RS21110 USER MANUAL Enter and select the array you want to delete, then press 'DEL' and select 'Y' to delete the array as shown below: 5. Operating system installation instructions This chapter describes the manual installation of the windwos server 2016 operating system and driver installation.
  • Page 17 RS21110 USER MANUAL 3. Select the "Driver" option on the navigation interface, enter the Driver interface, select the model where the operating system server needs to be installed, and then select the operating system that needs to be installed. 4. Enter the system driver interface, there are chipset driver, network card driver, graphics card driver and integrated RAID driver, etc.
  • Page 18 RS21110 USER MANUAL Select "Install now" when the image below appears. You need to select "Delete" to delete all partitions before installing the new system, press "Next".
  • Page 19 RS21110 USER MANUAL Select "Custom: install windows only(advanced), press the "Enter" key. Select "I accept the license terms", press "Next".
  • Page 20: Redhat Enterpise Linux 7.0 Installation Instructions

    RS21110 USER MANUAL Select "Datacenter Evaluation (Desktop experience)", press "Next" to install windows.After the installation, you have to install the driver, copy the driver to the USB flash drive, then install Chipset, follow the prompts until the driver is installed, as shown in the following figure. 5.2 Redhat Enterpise Linux 7.0 Installation Instructions This guide applies to the manual installation of the Red Hat Enterprise Linux AS 6.0 U8 operating system.
  • Page 21 RS21110 USER MANUAL 3. Go to the following screen and click Next...
  • Page 22 RS21110 USER MANUAL 4. The system enters the following screen, click Next 5. Select the system language, the default English, click Next, see the following figure...
  • Page 23 RS21110 USER MANUAL 6. Select the keyboard type, default, click Next, see the figure below. 7. Select the device type, default, click Next, see the figure below.
  • Page 24 RS21110 USER MANUAL 8. Select the time zone, select Chongqing, the following figure 9. Set the Root user password, click Next after setting, see the figure below.
  • Page 25 RS21110 USER MANUAL 10. Click on the Use Anyway box, see below. 11. Select the type of installation, mainly on the disk operation, select the custom system partition, you can choose the last item see below (if you need to install on the array card, the driver installation method refer to the corresponding RAID controller driver installation instructions)
  • Page 26 RS21110 USER MANUAL 12. Tap Next by default, as shown below. (You can also choose the last item to manually divide according to the actual demand) 13. Click the Format button in the prompt box, see below.
  • Page 27 RS21110 USER MANUAL 14. Click the prompt box Write change to disk 15. Click Next for the default selection, see the figure below.
  • Page 28 RS21110 USER MANUAL 16. Select the type of system to be installed, here choose the desktop version, see the following figure (or you can choose the installation package according to the demand) 17. System installation is in progress, wait for it, see the following figure...
  • Page 29 RS21110 USER MANUAL 18. After the installation is complete, click Reboot, see the figure below. 19. Click Forward on the Welcome page, see below.
  • Page 30 RS21110 USER MANUAL 20. Click Forward by default, see below. 21. Click Forward by default, see below.
  • Page 31 RS21110 USER MANUAL 22. Click Forward by default, see below. 23. Creating a user name and password Forward, see below...
  • Page 32 RS21110 USER MANUAL 24. To set the time and date, click 25. Setting is complete, click Finish, enter the system, see the following figure...
  • Page 33: System Troubleshooting

    RS21110 USER MANUAL 26. Enter the user name / password, enter the system, so the system installation is complete, see the following figure 6. System Troubleshooting 6.1 Introduction to System Reset This chapter helps you to check and solve problems that you may encounter while using the Bauder Server system.
  • Page 34: Initial System Startup

    RS21110 USER MANUAL 6.2 Initial system startup Problems with the first boot of a system are usually caused by incorrect installation or configuration. Failures directly attributable to hardware are relatively rare. Check the steps: . Are all cables properly connected and wired securely. .
  • Page 35: Specific Issues

    RS21110 USER MANUAL ast to at least two-thirds of their maximum values (see the documentation that came with the monitor). 4. Turn on the system. If the power indicator does not light up, see the troubleshooting description below for the power indicator does not light up. 6.3.2 Verification system indicators After POST detects the system configuration, the system tests whether each mass storage device is present.
  • Page 36 RS21110 USER MANUAL 6.4.3 Incorrect or distorted characters displayed on the screen Please check the following: - The brightness and contrast of the monitor are adjusted appropriately. See the monitor manufacturer's documentation. - The signal line power cable of the monitor is installed correctly. - The display card installed in the operating system is correct.
  • Page 37 RS21110 USER MANUAL - The CD-ROM is configured correctly. - Whether the motherboard's integrated IDE controller has been enabled. Attention: IDE and SATA Devices Indicated by Front Panel Lights: The Hard Disk Drive Activity light on the front panel illuminates when an IDE hard disk or a SATA device controlled by the motherboard's integrated SATA controller is in use.