FS RS5450 User Manual
Hide thumbs Also See for RS5450:

Advertisement

Quick Links

RS5450 USER MANUAL
1
www.fs.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RS5450 and is the answer not in the manual?

Questions and answers

Summary of Contents for FS RS5450

  • Page 1 RS5450 USER MANUAL www.fs.com...
  • Page 2: Table Of Contents

    1.8 Open the Display and the Server .............7 2. Description of the System Structure ............9 2.1 RS5450 Mechanical Features ............9 2.2 RS5450 Description of the Rear Window ........10 2.3 Jumper settings and connector descriptions .........12 3. System Description of the System Structure ........16 3.1 CPU ....................16...
  • Page 3 RS5450 USER MANUAL 6.System Troubleshooting ...............43 6.1 Introduction to System Reset ............43 6.2 The System Started for the First Time ..........43 6.3 Other Problems and Solutions ............45 6.3.1 Prepare the System for Diagnostic procedures ....45 6.3.2 Verify the System Indicator Light ........45 6.4 Concrete Issue ................45...
  • Page 4: Abstract

    RS5450 USER MANUAL 1.1 Abstract The main task of this chapter is to describe how to perform some basic preparatory work. These tasks include: Checking the shipping packaging; Selecting an appropriate location for placing the server; Checking the power settings switch;Inspecting the power cables;...
  • Page 5 RS5450 USER MANUAL The server can work reliably in a normal office environment. Select an environment that meets the following conditions: Clean and low in dust Meet the specific Well-ventilated and far away from the heat source environmental Stay away from environments that may encounter...
  • Page 6: The Server Is Installed On The Rack

    RS5450 USER MANUAL 1.4 The Server Is Installed on the Rack All rack-type servers are compatible with a 19-inch standard rack, installation procedures are described in the shelf Installation Guide. 1.5 Check the Power Cord If the supplied AC power cord does not match the model of the place where the server is used, do not continue, replace it with a compliant power cord.
  • Page 7: Add Equipment

    RS5450 USER MANUAL 1.6 Add Equipment Before adding the expansion device in your server, verify that the server is not connected to power. When you add drives, expansion cards, and memory, or make any internal changes to your server, restore the server chassis.
  • Page 8 RS5450 USER MANUAL when the hard disk receives an access signal. If the fault occurs, record the error message displayed on the screen and hear the sound code. See the System troubleshooting chapter. www.fs.com...
  • Page 9: Rs5450 Mechanical Features

    RS5450 USER MANUAL 2.1 RS5450 Mechanical Features Control panel indicator light instructions: Power Lamp Blue Light The server is being turned on vague (of Hard Disk Lamp Green Onboard hard disk data read/write speech) Network 1 Pilot Green Light Network is normally connected...
  • Page 10: Rs5450 Description Of The Rear Window

    Redundant power supplies for servers AC Voltage 100V/60Hz, 240V/50Hz Adaptive Frequency Chassis-shaped: Profile System Rackmount 4U Height 178mm Width 437mm Depth 437mm Weight(minimum configuration) About 58KG 2.2 RS5450 Description of the Rear Window Figure 2-3 RS5450 Rear Window IO diagram www.fs.com...
  • Page 11 RS5450 USER MANUAL Rear window IO description: USB2.0 interface, can be connected to USB keyboard and mouse, USB2.0 USB flash disk and other devices VGA interface, can be connected to the VGA interface monitor and other display devices Network port 1 2 LAN0 1 connector for Category 6 Gigabit cable USB3.0...
  • Page 12: Jumper Settings And Connector Descriptions

    RS5450 USER MANUAL 2.3 Jumper settings and connector descriptions www.fs.com...
  • Page 13 RS5450 USER MANUAL JBT1 Clear CMOS come on JPG1 VGA on Pins 1-2 (on) JPL1 LAN1/LAN2 on Pins 1-2 (on) JPME1 ME Recovery Pins 1-2 (Normal) JPME2 Production mode selection Pins 1-2 (Normal) JVRM1/ JVRM2 VRMSMB clock (BMC or PCH)
  • Page 14 RS5450 USER MANUAL Chassis intrusion connector JM2_1 M.2 connector JNVIC1 NVMe FC connector JNVME1/JNVME2 NVMe connector 1/NVMe connector 2 JPIC1 Power SMBbusI°C connector JPWR1/JPWR2 8-pin Power Connector JPWR3 24-pin ATX main power connector JRK1 Onboard SATA device RAID Key connector...
  • Page 15 RS5450 USER MANUAL USB2/3 USB2.0 connector USB6 (USB0/1) & Rear Panel USB3.0 connector (USB4/5) USB7/8 TypeAUSB3.0 connector VGA connector www.fs.com...
  • Page 16: Cpu

    RS5450 USER MANUAL 3.1 CPU 3. 1. 1 CPU Overview This series of models supports two Intel Xeon Scalable-SP and second generation Intel Xeon Scalable-SP series processors with UPI up to 10.4 GT/s 3. 1. 2 CPU Installation Steps 3.2 Memory 3.2.1 Memory Summary...
  • Page 17: Memory Installation Considerations

    RS5450 USER MANUAL 3.2.2 Memory Installation Considerations Because one CPU supports 8 memory slots, and two CPU' s support 16 memory slots, so one is used t he CPU and using the two CPU in memory are installed in a different order.
  • Page 18: Dcpmm Memory Installation Instructions

    RS5450 USER MANUAL See the following table for CPU and memory installation specifications Number of CPU CPU1 P1-DIMMA1 & Memory CPU1 P1-DIMMA1→P1-DMIMMD1→P1-DIMMB1→P1-DIMME1 1CPU & 1 Memory →P1 1CPU & 8 or less DIMMC1 →P1-DIMMF1→P1-DIMMA2-P1-DIMMD2 memory 2CPU&2Memory CPU1+CPU2P1-DIMMA1-P2-DIMMA1 P2-DIMMC1→P1-DIMMF1-P2-DIMMF1 →P1-DIMMA22-P2- 2CPU & 16 or less RAM DIMMA2→P1-DIMMD2→P2-DIMMD2...
  • Page 19: Video Controller

    RS5450 USER MANUAL Note: 1. 1Rx8 DDR4 memory does not support DCPMM. 2. DCPMM DIMMs are not installed in the memory DIMM slots corresponding to the second CPU socket. 3. For MM, typical MM/FM ratios range between 1:4 and 1:16. Excessive FM capacity can be used for AD (NM = Near Memory;...
  • Page 20: Network Controller

    RS5450 USER MANUAL 3.5 Network Controller Integrated 1Marvell 88E1512 Dual-Channel Gigabit Network Controller with two Gigabit Ethernet ports for high-speed network connectivity 3.6 Keyboard and Mouse USB keyboard / mouse support. 3.7 Optical Drives and Floppy Drives The server optionally supports a USB optical drive.
  • Page 21: Set The Raid Status In The Bios

    RS5450 USER MANUAL This chapter explains how to create RAID1, RAID0, and RAID10 using the motherboard's integrated SATA RAID controller. RAID1:After creating RAID1, the total disk capacity will be halved, as the disks are mirrored to provide backups, greatly improving reliability.
  • Page 22 RS5450 USER MANUAL 4.2.1.1.1 To create an array, select the Create RAID Volume option. The following menu will appear: Use the <↑> and <↓> keys to move the cursor up and down. In the **RAID Level** section, select the desired RAID level to create, with options including RAID0, RAID1, and RAID5. After selecting the RAID level and the disks for the array, press the **Create Volume** option and follow the prompts to choose 'Y' to create the array.
  • Page 23 RS5450 USER MANUAL 4.2.1.1.2 To delete an array, select the **Delete RAID Volume** option. The following menu will appear: Once inside, select the array you want to delete, then press ‘DEL’ and choose ‘Y’ to delete the array. The screen will look like this:...
  • Page 24: Microsoft Windows Server 2016 Installation Installations

    RS5450 USER MANUAL This chapter describes the manual installation and driver installation of the Windows Server 2016 operating system. 5.1 Microsoft Windows Server 2016 Installation Installations This guide is suitable for the manual installation of the Microsoft Windows 2008 Server R2 SP1 operating system.
  • Page 25 RS5450 USER MANUAL Start from the disc, load in 2.Go to the following screen and select the language / keyboard: www.fs.com...
  • Page 26 RS5450 USER MANUAL 3. Click to start the installation: 4. Select the type of operating system that you want to install, and press Next www.fs.com...
  • Page 27 RS5450 USER MANUAL 5. Read the User License Agreement with PAGE DOWN / PAGE UP: 6. Select the term I Accept the License Terms and press the term Next step 7. To select how to install the operating system www.fs.com...
  • Page 28 RS5450 USER MANUAL 8. If you do a RAID, the disk cannot be found. Select Load Driver for RAID driver loading to see the disk array. With the left mouse button, the load directory dialog box appears and select the copy directory of step 2 in 6. 1. 1. If the SATA disk is onboard AHCI mode can directly recognize the disk, no need to load the drive.
  • Page 29 RS5450 USER MANUAL 9. Srow space size on the disk array installation Windows Server 2016 10. Click OK to confirm the partition: www.fs.com...
  • Page 30 RS5450 USER MANUAL 1 1. Complete the partition, click Next to install the system; 12. Start copying the data, and install the system: www.fs.com...
  • Page 31 RS5450 USER MANUAL 13. Complete the installation, and restart the computer 14. You need to reset the password before entering the system 15. Enter the password to enter the system: www.fs.com...
  • Page 32 RS5450 USER MANUAL 16. Install the driver, put in the random drive disc, the drive disc open as shown below: 17. Click "Windows" to select the chip and controller to be driven, as shown in the figure below; 18. Install chipset, and other chip driver, graphics and external card drivers inside the expansion card drive disc, select to restart the computer after installation: Chipset main board chipset drive;...
  • Page 33: Redhat Enterprise Linux7.3 Installation Instructions

    RS5450 USER MANUAL 5.2 Redhat Enterprise Linux7.3 Installation Instructions 5.2.1 Preparations: If your server needs to load RAID drives when installing the operating system, prepare the U disk and random drive discs. If your server is configured with a RAID plug card, drive discs.
  • Page 34 RS5450 USER MANUAL 3 .Select the system language, the default English, and click on Next 4. The system goes to the following interface. (Set time, system package, hard disk partition) www.fs.com...
  • Page 35 RS5450 USER MANUAL 5. Click SOFTWARE SELECTION to select the system software; click Done to return to the step 4 interface; 6. Select INSTALLATION DESTINATION, hard disk partition; (optional automatic or manual partition) www.fs.com...
  • Page 36 RS5450 USER MANUAL 7. Click on Next, 8. Start installing the system as shown in the following figure www.fs.com...
  • Page 37 RS5450 USER MANUAL 9. Set the Root user password, and then click Done, see the figure below 10. Installation is complete, click on REBOOT, see the figure below www.fs.com...
  • Page 38 RS5450 USER MANUAL 1 1. License information 12. Default click FINISH CONFIGURATION ,as following picture shows: 13. Click on Next by default, see the figure below www.fs.com...
  • Page 39 RS5450 USER MANUAL 14. Click on Next by default, see the figure below 15 . Select the time zone (such as Shanghai) and click on Next, see the figure below www.fs.com...
  • Page 40 RS5450 USER MANUAL 16. Click on Skip and see the figure below 17. Create a user, see the figure below www.fs.com...
  • Page 41 RS5450 USER MANUAL 18 . Click Start using Red Hat Enterprise Linux Server to enter the system, see the figure below www.fs.com...
  • Page 42: Introduction To System Reset

    RS5450 USER MANUAL 6.1 Introduction to System Reset This chapter helps you check and resolve problems that you may encounter while using the Powerleader server system. <Ctrl>+<Alt>+<Del> ( Depending on Hot start: Clear the system memory and remount the operating system.
  • Page 43 RS5450 USER MANUAL Whether the configuration set by SSU is correct Whether the operating system is mounted correctly (see the operating system- related documentation) . Whether the server is turned on by pressing the system power button on the front panel...
  • Page 44: Other Problems And Solutions

    RS5450 USER MANUAL 6.3 Other Problems and Solutions 6.3.1 Prepare the System for Diagnostic procedures Turn off the device before unplugging the cable: Turn off the external device that is connected to the system before disconnecting the external cable from the system. Failure may result in damage to the system or external devices.
  • Page 45 RS5450 USER MANUAL There are other issues with the system. If so, check the items listed in "System Cooling Fan Not Spinning Properly. "If all checks are correct and the problem persists, contact your technial. www.fs.com...
  • Page 46: The Screen Does Not Display Characters

    RS5450 USER MANUAL 6.4.2 The Screen Does not Display Characters Check the following items: Whether the keyboard is working properly. Check to see if the "Num Lock" light is on. Whether the cable of the monitor is plugged in and whether the power is on. Many monitors now automatically turn off when not working, while when activated require a period of warm-up.
  • Page 47: The Working Led Of The Hard D Rive Is Not Lit

    RS5450 USER MANUAL Whether a short circuit is caused by a squeeze cable or the power connector incorrectly plugged into the power connector connector interface. If the connection is correct and there is AC power in the wall outlet, contact a technical support person or authorized dealer for assistance.
  • Page 48: Rohs Statement

    RS5450 USER MANUAL 7.1 ROHS Statement The RoHS Directive 2011 / 65 / EU (ROHS 2.0) was published in the official EU magazine on 1 July 2011 and in 2011 Effective on 21 July. According to ROHS 2.0, we collected the supplier material information and controlled the production process within the company.
  • Page 49: Recycling Instructions For Waste Electronics

    RS5450 USER MANUAL < 1000 < 1000 < 1000 < 1000 7.2 Recycling Instructions for Waste Electronics In order to protect the environment, protect human health, according to the law of the People' s Republic of China on environmental prevention and control of solid waste...

Table of Contents