Summary of Contents for FS RS5450

  • Page 1 S3400-24T4SP SWITCH SGNP CONFIGURATION RS5450 Rack Server Configuration Guide RS5450 Rack Server Configuration Guide Model: RS5450...
  • Page 2: Table Of Contents

    1.7 Connect peripherals ................................3 1.8 Turn on the monitor and server ............................3 Chapter 2 System structure description ....................5 2.1 Structural characteristics of RS5450 ........................... 5 2.2 Rear window diagram of RS5450 ............................7 2.3 Jumper setup and connector instructions ..........................9 Chapter 3 System description and Settings ..................
  • Page 3 RS5450 RACK SERVER CONFIGURATION GUIDE Chapter 5 Integrated RAID configuration ....................20 5.1 Setting RAID Status in the BIOS ............................20 5.2 Guide to Operating Integrated RAID on the Motherboard .................... 20 Chapter 6 Installation Instructions for the Operating System .............23 6.1 Red Hat Enterprise Linux 7.3 Installation Instructions ....................23 6.1.1 Preparation: ...........................................23...
  • Page 4: Chapter 1 Preparation For Use

    RS5450 RACK SERVER CONFIGURATION GUIDE Chapter 1 Preparation for use 1.1 Abstracts The main task of this chapter is to describe how to do some basic preparations. They include: Checking the shipping package; Choosing a suitable location to place the server;...
  • Page 5: Mount The Server On The Rack

    RS5450 RACK SERVER CONFIGURATION GUIDE Meet specialized environmental The server can reliably operate in a normal office regulations environment. Please choose an environment that meets the following conditions: Clean and low dust Well-ventilated, away from heat sources Away from environments that may...
  • Page 6: Add Equipment

    RS5450 RACK SERVER CONFIGURATION GUIDE Speed The AC current that the wires can carry should be rated at 125% of the current required by the server. Connect the power socket end The wire must be a positive plug with a grounded end.
  • Page 7 RS5450 RACK SERVER CONFIGURATION GUIDE Make sure all peripherals such as monitor, keyboard, mouse are connected. Remove the drive protection card from the disk drive (if present); Turn on the monitor; Connect one end of the AC power cable to the power port on the server backplane.
  • Page 8: Chapter 2 System Structure Description

    RS5450 RACK SERVER CONFIGURATION GUIDE Chapter 2 System structure description 2.1 Structural characteristics of RS5450 1. Enlarged view of front panel and indicator/control panel: 2. Control panel indicator description: Name Color Status Description Power Light Blue Bright The server is powered on...
  • Page 9 RS5450 RACK SERVER CONFIGURATION GUIDE module is faulty 3. Power Supply: Name Description Power supply Redundant power supply for the server Ac voltage/frequency 180-240V/, 50-60Hz adaptive 4. Chassis form: Name Description Contour system Rack mounted 4U Height 178mm Width 437mm...
  • Page 10: Rear Window Diagram Of Rs5450

    RS5450 RACK SERVER CONFIGURATION GUIDE 2.2 Rear window diagram of RS5450 1. Rear window IO Description: Name Description USB2.0 USB2.0 interface, compatible with USB keyboards, mice, USB drives, and other devices. VGA interface, compatible with VGA monitors and other display devices.
  • Page 11 RS5450 RACK SERVER CONFIGURATION GUIDE COM (DB9) COM port, compatible with COM interface devices. BMC Management Port (RJ45) BMC management port (RJ45), IPMI interface. It can be connected via an Ethernet cable and used to monitor and manage servers. UID Button/ UID LED ID light and button, pressing this button will illuminate the ID light.
  • Page 12: Jumper Setup And Connector Instructions

    RS5450 RACK SERVER CONFIGURATION GUIDE 2.3 Jumper setup and connector instructions Jumper Description Default setting JBT1 Clear CMOS Open (normal) JPG1 VGA on Pins 1-2(on) JPL1 LAN1/LAN2 Open Pins 1-2(on) JPME1 ME recovery Pins 1-2(Normal) JPME2 Production mode selection Pins 1-2(Normal)
  • Page 13 RS5450 RACK SERVER CONFIGURATION GUIDE Motherboard CMOS battery socket COM1/COM2 Rear panel C0M1/C0M2 expands the data header FAN1-6,FANAFANB System fan connectors (FAN1-FAN6,FANA,FANB) IPMI LAN IPMI dedicated network port I-SATA0-3,I-SATA4-7 Intel PCHSATA3.0 connector Power LED connector Front control panel connector JHFI1/JHFI2...
  • Page 14 RS5450 RACK SERVER CONFIGURATION GUIDE SLOT2 CPU1 supports PCI-Express3.0X16 slots SLOT4/SLOT5/SLOT6 PC1-Express3.0X16 slot supported by CPU2 T-SGPI03 SGP103 port Unit identification switch USB0/1 & USB4/5 USB2.0 ports on the rear panel (USB0/1)& USB3.0 ports on the rear panel (USB4/5) USB213 USB2.0 connector...
  • Page 15: Chapter 3 System Description And Settings

    RS5450 RACK SERVER CONFIGURATION GUIDE Chapter 3 System description and Settings 3.1 CPU 3.1.1 CPU Overview This series supports two Intel Xeon Scalable SP and second-generation Intel Xeon Scalable SP series processors, with UPI support of up to 10.4 GT/s.
  • Page 16: Internal Memory

    RS5450 RACK SERVER CONFIGURATION GUIDE 3.2 Internal memory 3.2.1 Memory overview The server has 16 memory slots and supports 16 Load Reduced DIMMs (LRDIMMs), 3D LRDIMM, Registered DIMM (RDIMM), Non-Volatile DIMM (NV-DIMM) DDR4 (288-pin) ECC 2933/2666/2400/2133 MHz memory (does not support the mixing of different memory types). The maximum memory size is 4TB. The server also supports DCPMM, the maximum support is 5TB, please refer to the following table.
  • Page 17: Dcpmm Memory Installation Description

    RS5450 RACK SERVER CONFIGURATION GUIDE Mapping between CPU and memory CPU1 P1-DIMM number CPU2 P2-DIMM number The following table describes the CPU and memory installation specifications: CPU and memory installation specifications Number of CPUs and memory CPU and memory installation sequence 1CPU&1 memory...
  • Page 18 RS5450 RACK SERVER CONFIGURATION GUIDE NOTE: 1. 1Rx8 DDR4 memory does not support DCPMM. 2. No DCPMM DIMMs are installed in the DIMM corresponding to the 2 * second CPU socket. 3. For MM, the typical MM/FM ratio is between 1:4 and 1:16. Excessive FM capacity can be used for AD (NM= near memory;...
  • Page 19: Video Controller

    RS5450 RACK SERVER CONFIGURATION GUIDE 3.3 Video controller Motherboard integrated ASpeed2500 video controller via AST 2500BMC, 3.4 3.4 Disk Controller Supports 14 SATA3 hard disks. 3.5 Network Controller The integrated 1Marvell 88E1512 dual-channel Gigabit network controller provides two Gigabit network ports for high-speed network connectivity.
  • Page 20 RS5450 RACK SERVER CONFIGURATION GUIDE Serial number Operating System Microsoft Windows 2016 Red Hat Enterprise Linux 7.6 ww.fs.com...
  • Page 21: Chapter 4 Bios Settings

    RS5450 RACK SERVER CONFIGURATION GUIDE Chapter 4 BIOS Settings BIOS stands for Basic Input/Output System. Basic hardware management before entering an operating system such as Windows. You can solve many hardware compatibility problems by upgrading and setting the BIOS. This chapter focuses on the BIOS configuration menu.
  • Page 22 RS5450 RACK SERVER CONFIGURATION GUIDE Toggle: Left and right buttons are used to switch between main menu <←>,<→> pages. Left and right buttons do not work in submenus or selection lists. Select: Used to select between different files. For example, the Tab key can change from the hour to the minute.
  • Page 23: Chapter 5 Integrated Raid Configuration

    RS5450 RACK SERVER CONFIGURATION GUIDE Chapter 5 Integrated RAID configuration This chapter describes how to create RAID1, RAID0, and RAID10 using the motherboard's integrated SATA RAID controller. After RAID1 is created, the capacity of the hard drives is only half of the total capacity because the drives are mirrored, greatly increasing reliability.
  • Page 24 RS5450 RACK SERVER CONFIGURATION GUIDE Use the <↑> and <↓> keys to move the cursor up and down. At "RAID Level," choose the level of the array you wish to establish. The options available are RAID0, RAID1, and RAID5. After selecting the array level and the hard drives for the array, hit the "Create Volume"...
  • Page 25 RS5450 RACK SERVER CONFIGURATION GUIDE After entering, select the array you wish to delete, then press 'DEL' and choose 'Y' to delete the array, as shown in the figure below: ww.fs.com...
  • Page 26: Chapter 6 Installation Instructions For The Operating System

    RS5450 RACK SERVER CONFIGURATION GUIDE Chapter 6 Installation Instructions for the Operating System This chapter describes the manual installation of the Red Hat Enterprise Linux 7.3. 6.1 Red Hat Enterprise Linux 7.3 Installation Instructions 6.1.1 Preparation: If your server requires loading RAID drivers during the operating system installation, please prepare a USB drive and the random driver CD.
  • Page 27 RS5450 RACK SERVER CONFIGURATION GUIDE 4. The system enters the following interface. (Configure the time, system packages, and hard disk partitioning) 5. Click on SOFTWARE SELECTION to choose system software; click Done to return to step four. ww.fs.com...
  • Page 28 RS5450 RACK SERVER CONFIGURATION GUIDE 6. Choose INSTALLATION DESTINATION for hard disk partitioning; (You can choose either automatic or manual partitioning) 7. Click Next. ww.fs.com...
  • Page 29 RS5450 RACK SERVER CONFIGURATION GUIDE 8. Begin the installation of the system, as shown below. 9. Set the root user password and after setting it, click Done, as seen below. ww.fs.com...
  • Page 30 RS5450 RACK SERVER CONFIGURATION GUIDE 10. Once the installation is complete, click REBOOT, as seen below. 11. Licensing Information ww.fs.com...
  • Page 31 RS5450 RACK SERVER CONFIGURATION GUIDE 12. By default, click FINISH CONFIGURATION, as shown below. 13. By default, click Next, as seen below. ww.fs.com...
  • Page 32 RS5450 RACK SERVER CONFIGURATION GUIDE 14. By default, click Next, as seen below. 15. Select the time zone (e.g., Shanghai) and click Next, as seen below. ww.fs.com...
  • Page 33 RS5450 RACK SERVER CONFIGURATION GUIDE 16. Click Skip, as seen below. 17. Create a user, as seen below. ww.fs.com...
  • Page 34 RS5450 RACK SERVER CONFIGURATION GUIDE 18. Click Start using Red Hat Enterprise Linux Server to enter the system, as seen below. ww.fs.com...
  • Page 35: Chapter 7 System Troubleshooting

    RS5450 RACK SERVER CONFIGURATION GUIDE Chapter 7 System Troubleshooting 7.1 Introduction to System Reset This chapter will assist you in checking and solving potential issues that may arise while using the Positivo server systems. Task Key(s) Combination Warm Boot: Clears the system memory and reloads the <Ctrl>+<Alt>+<Del>...
  • Page 36: Other Issues And Solutions

    RS5450 RACK SERVER CONFIGURATION GUIDE Check if the configuration set by the SSU is correct. Ensure that the operating system is loaded correctly (see related operating system documentation). Check if the server has been powered on using the system power button on the front panel (the power light indicator should be on).
  • Page 37: Screen Does Not Display Characters

    RS5450 RACK SERVER CONFIGURATION GUIDE Ensure all power cords are firmly connected. Check if the power cord is attached to a junction box or an electrical outlet. Also, check if your fuses or circuit breakers have been tripped or damaged.
  • Page 38: The Hard Drive Activity Indicator Light Does Not Turn On

    RS5450 RACK SERVER CONFIGURATION GUIDE Whether there is alternating current in the wall outlet. Whether the system power cord is correctly connected to the system and the wall outlet. Whether the power button has been pressed. Whether the power indicator light is on.
  • Page 39: The Bootable Disc Cannot Boot By Itself

    RS5450 RACK SERVER CONFIGURATION GUIDE 7.4.7 The bootable disc cannot boot by itself If the disc being used is a bootable disc for the system, please check the following setting: Whether the CD-ROM has been set as the first boot device in the BIOS settings.
  • Page 40: Chapter 8 Environmental Protection Declaration

    RS5450 RACK SERVER CONFIGURATION GUIDE Chapter 8 Environmental Protection Declaration 8.1 RoHS Declaration The RoHS Directive, also known as 2011/65/EU (RoHS 2.0), was published in the Official Journal of the European Union on July 1, 2011, and took effect on July 21, 2011.
  • Page 41 RS5450 RACK SERVER CONFIGURATION GUIDE The primary controlled items of discarded products include: waste cardboard boxes and other packaging materials, waste PE bags, plastic products such as glue bottles, waste glass containers, waste batteries containing zinc and cadmium, waste organic solvents, and discarded whole computers and monitors.