Advertisement

Quick Links

RS5230 USER MANUAL
RS5230
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RS5230 and is the answer not in the manual?

Questions and answers

Summary of Contents for FS RS5230

  • Page 1 RS5230 USER MANUAL RS5230 User Manual...
  • Page 2: Table Of Contents

    RS5230 USER MANUAL Contents 1. Preparation for Use ..........................1 1.1 Abstract ..............................1 1.2 Check the Transport Package......................1 1.3 Select a Suitable Location to Place the Server................2 1.4 Mount the Server on the Rack......................2 1.5 Check the Power Cord........................... 3 1.6 Add Equipment ............................3...
  • Page 3 RS5230 USER MANUAL 6.1 Microsoft Windows Server 2016 Installation Instructions............33 6.2 Redhat Enterpise Linux7.3 Installation Instructions ..............42 7. System Troubleshooting........................51 7.1 Introduction to System Reset......................51 7.2 The System Started for the First Time .................... 51 7.3 Other Problems and Solutions......................52 7.4 Specific Questions..........................52...
  • Page 4: Preparation For Use

    RS5230 USER MANUAL 1. Preparation for Use 1.1 Abstract The main task of this chapter is to describe how to do some basic preparations. They include: Check the transportation and packaging; Select a suitable location for the server; Check the power supply setting switch;...
  • Page 5: Select A Suitable Location To Place The Server

    RS5230 USER MANUAL 1.3 Select a Suitable Location to Place the Server Required Conditions Illustration A three-pin power outlet that conforms to local electricity With three-pin power standards. The expected overload current is 13A, or less than socket 100-120VAC/6.5A or less than 200-240VAC.
  • Page 6: Check The Power Cord

    RS5230 USER MANUAL 1.5 Check the Power Cord If the supplied AC power cord does not match the model number where the server is being used, do not continue to use it and replace it with a compatible power cord. Compliant power cords are described below.
  • Page 7: Turn On The Monitor And Server

    RS5230 USER MANUAL them to configure the server. If necessary, connect other expansion devices, such as: printer, modem, etc. 1.8 Turn on the Monitor And Server Warning: The power switch on the front panel does not cut off the AC voltage. To remove AC voltage from the server, the AC power cord must be disconnected.
  • Page 8: System Structure Description

    RS5230 USER MANUAL 2. System Structure Description 2.1 PR 1710 P Front Panel Description and Structural Characteristics Enlarged view of PR1710P-4-bay front panel and indicator / control panel : Figure 2- 1 Front panel diagram of PR1710P-4 disk server Enlarged view of PR1710P-10 bay front panel and indicator / control panel :...
  • Page 9 RS5230 USER MANUAL Sensors such as server fan, temperature sensor or voltage are in abnormal state Steady on: The temperature System Status Light Flicker sensor is abnormal 4 Hz: The power module is abnormal 2 Hz: Fan, voltage sensor abnormal...
  • Page 10: Pr 1710 P Rear Window Description

    RS5230 USER MANUAL PR1710P-10 bay 2.5-inch hard disk installation and hard disk bay indicator description: Figure 2- 4 2.5-inch hard drive bay installation and bay indicator description Power Supply: Electricity Source Redundant power supply for servers Input the AC voltage/...
  • Page 11: Jumper Settings And Connector Description

    RS5230 USER MANUAL 2.3 Jumper Settings and Connector Description Rear Window IO Description: Power 1, Power 2 (optional) LAN1 2 interface, can be connected to Category 6 Gigabit Ethernet cable (does not support 100M or below network) ID light and BMC restart button, press the switch board ID button, the light will turn on.
  • Page 12 RS5230 USER MANUAL Double-color Green The IPMI works at 1Gbps The network connection is Flicker normal LAN1/2 Green Extinguish No LAN connection Green LAN works at 1Gbps www.fs.com...
  • Page 13: Pr2710P Front Panel Description And Structural Characteristics

    RS5230 USER MANUAL 2.4 PR2710P Front Panel Description and Structural Characteristics Enlarged view of PR2710P-8-bay front panel and indicator / control panel : Figure 2- 5 Front panel diagram of PR2710P-8 disk server Enlarged view of PR2710P-12-bay front panel and indicator / control panel :...
  • Page 14 RS5230 USER MANUAL Description of the control panel indicators: Name Color State Ilustration Server is powered on Power Light Bright Blue Netwok 1 Indicator Onboard network 1 connection Green Bright Light is OK and active Onboard network 2 connection Netwok 2 Indicator...
  • Page 15 RS5230 USER MANUAL PR2710P-8-bay 3.5-inch hard drive bay installation and hard drive bay indicator light description: Figure 2- 8 3.5-inch hard drive bay installation and bay indicator description Figure 2- 9 2.5-inch hard drive bay installation and bay indicator description...
  • Page 16: Pr2710P Rear Window Description

    RS5230 USER MANUAL 2.5 PR2710P Rear Window Description Figure 2- 10 PR2710P style A rear window IO diagram Figure 2- 11 PR2710P style B rear window IO diagram 2.6 2710P Rear Window IO Description Style A rear window IO description: Optional installation of 2.5-inch modules, support for SAS/SATA/NVME hard...
  • Page 17 RS5230 USER MANUAL IPMI interface, IPMI2.0 interface, can be connected to Category 6 Gigabit Ethernet cable, monitor and manage the server through this interface 9-11 USB3.0 interface, can connect USB keyboard, mouse, USB3.0 U disk and other devices PCI-E 3.0 X8 slot, can insert half-height PCI-E 3.0 X8 card, backward compatible PCI-E 3.0 X16 slot, can insert half-height PCI-E 3.0 X16 card, backward...
  • Page 18 RS5230 USER MANUAL PCI-E 3.0 X16 slot, can insert half-height PCI-E 3.0 X16 card, backward compatible 17-18 Different types of OCP cards can be selected, OCP network ports 1 and 2 www.fs.com...
  • Page 19 RS5230 USER MANUAL Description of the working status of the rear window network light: Name Color State Ilustration Network connection is Yellow Flicker normal The IPMI works at 100Mbps Managementport Green/Orange Orange Double-color (RJ45) The IPMI works at 1Gbps Green...
  • Page 20: Jumper Settings And Connector Descriptions

    RS5230 USER MANUAL 2.7 Jumper Settings and Connector Descriptions www.fs.com...
  • Page 21 RS5230 USER MANUAL Jumpers Description Default Setting JBAT8 Clear CMOS Pins 1-2 (Restore jumper) JSDO8 Flash Memory Pin 1-2 (Normal) Names Description OCP1 OCP Type A Slot OCP2 OCP Type C Slot MINISAS HD1 Intel PCH SATA 0-3 MINISAS HD2...
  • Page 22 RS5230 USER MANUAL JPWRS OCP Type A Slot JPWR7~9 Front HDD hard disk rear panel power-supply ports JPWR1, JPWR2 Power module 1/2 ports BIOS ROM port BMC ROM port PCI-E_SLOT1 PCI-E3.0x16 (CPU0) PCI-E_SLOT2 PCI-E3.0x8 (CPUO)/1U horizontal adapter card slot PCI-E_SLOT3 PCI-E3.0x24 (CPU1), 1U/2U PCIE horizontal adapter card slot...
  • Page 23: System Description And Settings

    RS5230 USER MANUAL 3. System Description and Settings 3.1 CPU 3.1.1 CPU Summary This series of models supports two Intel Xeon Scalable-SP and 2nd generation Intel Xeon Scalable-SP series processors, with a UPI of up to 10.4 GT/s and a maximum of 165W.
  • Page 24: Ram

    RS5230 USER MANUAL 3.2 RAM 3. 2. 1 Memory Overview Server has 16 memory slots that can support 16 Load Reduced DIMM (LRDIMM), 3D LRDIMM, Registered DIMM (RDIMM), Non-Volatile DIMM (NV-DIMM) DDR4 (288-pin). ECC 2933/2666/2400/ 2133 MHz memory (does not support mixing of different types of memory), supports up to 4TB memory.
  • Page 25 RS5230 USER MANUAL The corresponding relationship between CPU and memory is shown in the following table: See the following table for the installation specifications of CPU and memory: Notice: 1. In order to ensure the smooth realization of the memory function, it should be ensured that the same server uses exactly the same memory products, mainly including memory capacity and particle model.
  • Page 26 RS5230 USER MANUAL Notice: 1. 1Rx8 DDR4 memory does not support DCPMM. 2. There is no DCPMM DIMM installed in the memory DIMM corresponding to the second CPU socket. 3. For MM, a typical MM/FM ratio is between 1:4 and 1:16. Excessive FM capacity can be used for AD (NM = near memory;...
  • Page 27: Video Controller

    RS5230 USER MANUAL 3.3 Video Controller Motherboard integrates ASpeed2500 video controller through AST 2500BMC. 3.4 Hard Disk Controller Support 14 SATA3 hard drives. 3.5 Network Controller Integrated 1Marvell 88E1512 dual-channel Gigabit network controller , providing two Gigabit Ethernet ports, providing high-speed network connection , optional support for Gigabit or 10 Gigabit OCP network card (selecting 10 Gigabit OCP requires a 622 chipset version motherboard).
  • Page 28: Other Configuration

    RS5230 USER MANUAL 3.9 Other Configuration 5 USB 3.0 ports (2 front and 3 rear), 1 USB2.0 (built-in), and 1 BMC management network port. Number Operating System Microsoft Windows 2012R2 Microsoft Windows 2016 Red Hat Enterprise Linux 7.3 3.10 Certified Compatible Operating System...
  • Page 29: The Bios Settings

    RS5230 USER MANUAL 4. The BIOS Settings BIOS is an acronym for Basic Input Output System. Perform basic management of hardware before entering Windows and other operating systems. Many hardware compatibility issues can be resolved through BIOS upgrades and settings. This chapter focuses on the BIOS setup menu .
  • Page 30 RS5230 USER MANUAL selection. www.fs.com...
  • Page 31 RS5230 USER MANUAL Switching: The left and right keys are used to switch between the <↑>,<↓> main menu pages. The left and right keys do not work in submenus or selection lists. Select: Used to select between different files, for example the Tab <←>,<→>...
  • Page 32: Integrated Raid Configuration

    RS5230 USER MANUAL 5. Integrated RAID Configuration This chapter introduces the use of the motherboard integrated SATA RAID controller to create RAID1 , RAID0 and RAID10. After RAID1 is created, the hard disk capacity is only half of the total capacity, and the hard disk forms a backup, and the reliability is greatly improved.
  • Page 33 RS5230 USER MANUAL 5.1.1 Operating Guide for Mainboard Integrated RAID Before configuring the array, set the RAID controller mode in the BIOS, and press the combination of <Ctrl>+< I > to enter the RAID setting during the power-on self-test. After entering, the picture is as follows: 5.2.1.1.1 To create an array, select the Create RAID Volume option and the following menu...
  • Page 34 RS5230 USER MANUAL Press the < ↑ >, < ↓ > keys to move the cursor up and down, and select the desired level of the array at RAID Level. The options are RAID0, RAID1 and RAID5. After selecting the array level and the hard disks to be arrayed, click the Create Volume option and follow the prompts to select 'Y' to create an array.
  • Page 35 RS5230 USER MANUAL After entering, select the array to be deleted, then press 'DEL' , and select 'Y' to delete the array, as shown in the following figure: www.fs.com...
  • Page 36: Operating System Installation Instructions

    RS5230 USER MANUAL 6. Operating System Installation Instructions This chapter describes the manual installation and driver installation of the Windows Server 2016 operating system. 6.1 Microsoft Windows Server 2016 Installation Instructions This guide is suitable for the manual installation of the Microsoft Windows 2008 Server R2 SP1 operating system.
  • Page 37 RS5230 USER MANUAL 6.1.2 Installation Steps: 1. Set the CD-ROM as the first boot device in the BIOS, insert the Windows 2016 Server installation CD, save the BIOS settings, and restart. 2. Boot from CD, loading 3. Enter the following screen, select language/keyboard:...
  • Page 38 RS5230 USER MANUAL 4. Click to start the installation: 5. Select the type of operating system that you want to install, and press Next www.fs.com...
  • Page 39 RS5230 USER MANUAL 6. Read the User License Agreement with PAGE DOWN / PAGE UP: 7. Select "I accept the license terms", press "Next" 8. Choose how to install the operating system 9. If you do RAID , the disk will not be found. Choose to load the driver, load the RAID driver, and then you can see the disk array.
  • Page 40 RS5230 USER MANUAL Directory dialog box will pop up, select the copy directory in step 2 in 6.1.1 . If the SATA disk is connected to the on-board AHCI mode, the disk can be directly recognized without loading the driver.
  • Page 41 RS5230 USER MANUAL 11. Click OK to confirm the partition: 12. Complete the partition, click Next to install the system; www.fs.com...
  • Page 42 RS5230 USER MANUAL 13. Start copying the data, and install the system: 14. Complete the installation, and restart the computer 15. Before entering the system, you need to reset the password: www.fs.com...
  • Page 43 RS5230 USER MANUAL 16. Enter the password to enter the system: 17. Install the driver, put in the random drive disc, the drive disc open as shown below: 18. Click "Windows" to select the chip and controller to be driven, as shown in the figure below;...
  • Page 44 RS5230 USER MANUAL LAN is an integrated network card driver for the motherboard; SATA RAID is the motherboard integrated SATA and SATA driver; USB3.0 is the motherboard integrated 3.0 driver; VGA is the motherboard integrated graphics driver. www.fs.com...
  • Page 45: Redhat Enterpise Linux7.3 Installation Instructions

    RS5230 USER MANUAL 6.2 Redhat Enterpise Linux7.3 Installation Instructions 6.2.1 Preparations: RAID driver when installing the operating system , please prepare a U disk and a random driver CD. If your server is configured with a RAID external card, you need to prepare the external card driver CD.
  • Page 46 RS5230 USER MANUAL 3. Select the system language, the default English, and click on Next 4. The system goes to the following interface. (Set time, system package, hard disk partition) www.fs.com...
  • Page 47 RS5230 USER MANUAL 5. Click SOFTWARE SELECTION to select the system software; click Done to return to the step 4 interface; 6. Select INSTALLATION DESTINATION, hard disk partition; (optional automatic or manual partition) www.fs.com...
  • Page 48 RS5230 USER MANUAL 7. Click on Next, 8. Start to install the system, as shown below www.fs.com...
  • Page 49 RS5230 USER MANUAL 9. Set the Root user password, and then click Done, see the figure below 10. After the installation is complete, click REBOOT, see the figure below www.fs.com...
  • Page 50 RS5230 USER MANUAL 11. License information 12. Default click FINISH CONFIGURATION ,as following picture shows: www.fs.com...
  • Page 51 RS5230 USER MANUAL 13. Click on Next by default, see the figure below 14. Click on Next by default, see the figure below www.fs.com...
  • Page 52 RS5230 USER MANUAL 15. Select the time zone (such as Shanghai) and click on Next, see the figure below 16. Click on Skip and see the figure below www.fs.com...
  • Page 53 RS5230 USER MANUAL 17. Create a user, see the figure below 18. Click Start using Red Hat Enterprise Linux Server to enter the system, see the figure below www.fs.com...
  • Page 54: System Troubleshooting

    RS5230 USER MANUAL 7. System Troubleshooting 7.1 Introduction to System Reset This chapter helps you to check and solve the problems that you may encounter in the process of using the Boyd server system. Task Keys (combination) Warm Boot: Clears system memory and reloads <Ctrl>+<Alt>+<Del>...
  • Page 55: Other Problems And Solutions

    RS5230 USER MANUAL documentation). • The server has been turned on by pressing the system power button on the front panel (the power-on light should be on). • The system power cord is properly connected to the system and plugged into an outlet.
  • Page 56 RS5230 USER MANUAL • Are all power cords plugged in securely. Whether the power cord is connected to the junction box or socket. Whether your fuse or fuse is damaged. • Whether the system is operating normally. If OK, there may be a problem with the power light, or a loose cable from the front panel to the motherboard.
  • Page 57 RS5230 USER MANUAL status). • Whether the fan power connector is properly connected to the board. Whether the cables coming out of the front panel are properly connected to the motherboard. • Whether the power cord is properly connected to the motherboard.
  • Page 58: Statement On Environmental Protection

    RS5230 USER MANUAL 8. Statement on Environmental Protection 8.1 ROHS Statement The RoHS Directive 2011 / 65 / EU (ROHS 2.0) was published in the official EU magazine on 1 July 2011 and in 2011 Effective on 21 July. According to ROHS 2.0, we collected the supplier material information and controlled the production process within the company.
  • Page 59: Instructions For Recycling Waste Electronic Products

    RS5230 USER MANUAL DEHP <1000 <1000 <1000 <1000 <1000 <1000 8.2 Instructions for Recycling Waste Electronic Products In order to protect the environment and protect human health, according to the Law of the People's Republic of China on the Prevention and Control of Environmental Pollution by Solid...

Table of Contents