-22-
SSB
OPERATION
1.
RECEIVING
After connecting an antenna, microphone, etc., set knobs and switches as follows.
POWER
SWITCH
OFF
(button out position)
T/R SWITCH
©
|
RECEIVE
(UP)
VOX
SWITCH
|
ОЕЕ
(ОР)
АСС
SWITCH
SLOW
(ОР)
. NB
(NOISE
BLANKER)
SWITCH
OFF
(UP)
MODE
SELECT
SWITCH
USB
or LSB
VFO
SWITCH
"А" or "В"
AF GAIN
CONTROL
Fully Counterclockwise
RF GAIN
CONTROL
Fully Clockwise
SOL CONTROL
Fully Counterclockwise
DIAL
LOCK
SWITCH
OFF
(UP)
RIT CONTROL
Center (12 o'clock) position
NB
(NOISE
BLANKER)
. nearby frequency or when there is continuous (not pulse type) noise.
AGC
(AUTOMATIC
GAIN
CONTROL)
The IC-551D
has а fast attack/slow release AGC system which holds the peak voltage of
rectified IF signals from the IF amp circuit for a certain period. Therefore, during the pauses
її normal speech of the received signal, uncomfortable noise will not be heard.
The multi-
function meter indicates the peak value for a certain period, facilitating reading of the meter
"S" function.
|
|