MERAWEX ZDSO500-DR2 Operating Manual

Power supply units for voice alarm systems (vas)

Advertisement

Quick Links

Operating manual for ZDSO500-DR2 and -DR3
MERAWEX Sp. z o.o.
Toruńska 8
44-122 Gliwice
tel. +48 32 23 99 400
e-mail:
merawex@merawex.com.pl
http://www.merawex.com.pl
Power supply units for voice alarm systems (VAS)
Certificate of constancy of performance no. 1438-CPR-0922
1.
GENERAL DESCRIPTION AND PURPOSE ............................................................................. 2
2.
ELECTRICAL PARAMETERS .................................................................................................. 4
3.
MECHANICAL AND ENVIRONMENTAL PARAMETERS. ...................................................... 6
4.
OPERATING PRINCIPLE .......................................................................................................... 7
5.
COOPERATION WITH BATTERY ............................................................................................ 9
6.
OPERATING MODES OF THE PSU ....................................................................................... 10
7.
BATTERY SELECTION. .......................................................................................................... 11
8.
INSTALLATION AND CONNECTION ..................................................................................... 15
9.
SERVICE .................................................................................................................................. 18
10.
CE MARKING ....................................................................................................................... 22
11.
HANDLING OF PACKAGING AND END-OF-LIFE PRODUCTS ........................................ 22
Doc. no. 0862.00.95-02.0
OPERATING MANUAL
type
ZDSO500-DR2 and ZDSO500-DR3
complies with EN 54-4
Declaration of performance DWU-MX-21
06.02.2023
Page: 1/22

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZDSO500-DR2 and is the answer not in the manual?

Questions and answers

Summary of Contents for MERAWEX ZDSO500-DR2

  • Page 1: Table Of Contents

    Operating manual for ZDSO500-DR2 and -DR3 Doc. no. 0862.00.95-02.0 Page: 1/22 MERAWEX Sp. z o.o. Toruńska 8 44-122 Gliwice tel. +48 32 23 99 400 e-mail: merawex@merawex.com.pl http://www.merawex.com.pl OPERATING MANUAL Power supply units for voice alarm systems (VAS) type ZDSO500-DR2 and ZDSO500-DR3 complies with EN 54-4 Certificate of constancy of performance no.
  • Page 2: General Description And Purpose

    Operating manual for ZDSO500-DR2 and -DR3 Doc. no. 0862.00.95-02.0 Page: 2/22 Warnings ▪ Please read this operating manual carefully before operating the device. ▪ Do not touch internal components of the operating device - risk of shock or burns. ▪...
  • Page 3 Operating manual for ZDSO500-DR2 and -DR3 Doc. no. 0862.00.95-02.0 Page: 3/22 Fig.1. View of the front and rear panels of ZDSO500-DR PSU The front panel of the PSUs features a set of 4 indicator LEDs, a multifunction ST button and a USB digital communication connector socket (type B).
  • Page 4: Electrical Parameters

    Operating manual for ZDSO500-DR2 and -DR3 Doc. no. 0862.00.95-02.0 Page: 4/22 Guaranteed voltage outputs with internal safety fuses and LED 8.5. indication of their blowing. Temp Two sockets for connecting temperature sensors. 8.10. sensor Bat fault Three relay indication outputs with available changeover Gen fault 8.9.
  • Page 5 Operating manual for ZDSO500-DR2 and -DR3 Doc. no. 0862.00.95-02.0 Page: 5/22 10...65 mΩ *6) Max. resistance of a single battery circuit Max. load current of a single battery bank 200A Current consumption from the battery for the PSU − with RGR connected...
  • Page 6: Mechanical And Environmental Parameters

    19-inch rack. Meeting the requirements of EN 54-4 requires that the rack in which the VAS is installed has an IP30 protection level. Fig.2. View and overall dimensions of ZDSO500-DR3 and ZDSO500-DR2 PSUs. Mechanical and environmental parameters Mechanical parameters Overall dimensions (W x H x D) 483(19") ×...
  • Page 7: Operating Principle

    Page: 7/22 4. Operating principle Simplified PSU diagrams are shown below in Figures and 4. ZDSO500-DR2 PSU is a structurally simplified version of ZDSO500-DR3 PSU. The PSU system is based on a so-called direct floating mode. The mains rectifiers (...
  • Page 8 Operating manual for ZDSO500-DR2 and -DR3 Doc. no. 0862.00.95-02.0 Page: 8/22 Mains Battery RECTIFIER VPS-2-640A Charging Fault 500W ZDSO500-DR3 LED SIGNALLING PANEL RECTIFIER PANEL SYGNALIZACYJNY LED 500W PROSTOWNIK BD 1 BD 2 RESISTANCE MEASUREMENT SYSTEM LVDD ETHERNET MICROPROCESSOR CONTROLLER Temp...
  • Page 9: Cooperation With Battery

    BAT #1 12V BATTERY 12V BATTERY Fig. 4. Simplified diagram of ZDSO500-DR2 PSU 5. Cooperation with battery The ZDSO500-DR PSU system allows to work with a batteries in one of two modes. Operation mode can only be selected using an external computer via a USB port. Floating mode is factory setting mode.
  • Page 10: Operating Modes Of The Psu

    Operating manual for ZDSO500-DR2 and -DR3 Doc. no. 0862.00.95-02.0 Page: 10/22 predetermined level, at which point the is activated and the supplementary charging process is LVDD triggered. Once this process is completed, is disconnected again and the cycle repeats. LVDD...
  • Page 11: Battery Selection

    EN 54-4 also defines the Imax_b current as the maximum, short-term current that can be drawn when the battery bank is not required to be charged. For ZDSO500-DR2 and ZDSO500-DR3 PSUs, these will be outputs at all, i.e. 15A and 2× 15A respectively (see the maximum currents that can be drawn from the section.
  • Page 12 In ZDSO500-DR PSUs, the Aux outputs are used for this purpose. The load level can vary from a fraction to tens of amperes (maximum 15A for ZDSO500-DR2 PSU and 30A for ZDSO500- DR3 PSU).
  • Page 13 Operating manual for ZDSO500-DR2 and -DR3 Doc. no. 0862.00.95-02.0 Page: 13/22 Attention. The battery bank working together must be of the same type, same capacity and same state (degree of charge). Example. In the VAS, due to the number of power supply outputs for the acoustic power amplifiers, ZDSO500- DR2 PSU is envisaged.
  • Page 14 A brief description of the meaning of each switch position is provided next to the switch. The minimum capacity size is 100Ah for ZDSO500-DR2 PSU and 200Ah for ZDSO500-DR3 PSU, which by means of the next two sliders: 1. and 2. can be enlarged. The resulting capacity is the sum of the minimum volume and the values assigned to individual sliders set to the ON (raised) position.
  • Page 15: Installation And Connection

    Operating manual for ZDSO500-DR2 and -DR3 Doc. no. 0862.00.95-02.0 Page: 15/22 8. Installation and connection 8.1. Assembly The PSU cassette is suitable for installation in a typical 19-inch rack. The use of guides to support the cassette is required, however, these must not cover the ventilation openings located on either side of the cassette (at least 8 cm ventilation space must be provided).
  • Page 16 Each Aux output is fitted with its own safety fuse. These outputs are grouped into sets (Aux1..Aux4 for the ZDSO500-DR2 PSU and Aux1...Aux4 and Aux5...Aux8 for the ZDSO500-DR3 PSU). Each set has an additional common fuse that limits the total current that can be drawn from that set (see...
  • Page 17 Operating manual for ZDSO500-DR2 and -DR3 Doc. no. 0862.00.95-02.0 Page: 17/22 The PSU is not equipped with a fuse for battery bank circuit and its design is based on a common negative bus. Therefore, a suitable fuse should be fitted in the immediate vicinity of the positive pole of the battery bank to protect against the effects of a possible short circuit (see Fig.3...
  • Page 18: Temp Sensor

    Any comments or concerns arising from this should be brought to the attention of the manufacturer to assess their potential impact on further operation. For technical and service issues and periodic inspections, please contact directly the MERAWEX Service Department or the manufacturer's authorized body.
  • Page 19 Operating manual for ZDSO500-DR2 and -DR3 Doc. no. 0862.00.95-02.0 Page: 19/22 The metal enclosure of the PSU is connected to the protective terminal of the mains power supply cable, and the anti-interference filters used in the PSUs are equipped with capacitors that cause leakage current to appear in this cable.
  • Page 20 Operating manual for ZDSO500-DR2 and -DR3 Doc. no. 0862.00.95-02.0 Page: 20/22 LED indication on the rear panel. All the LEDs are yellow. DESCRIPTION STATUS DESCRIPTION OF AN INCIDENT Defective fuse for an output in question Each output extinguished Output available.
  • Page 21 Operating manual for ZDSO500-DR2 and -DR3 Doc. no. 0862.00.95-02.0 Page: 21/22 9.6.2. Quick operation test. On the rear panel of the PSU, near the slide switch, there is an SRV button for two quick tests: • a short press of the button starts the measurement of the resistance of the battery circuits;...
  • Page 22: Ce Marking

    Doc. no. 0862.00.95-02.0 Page: 22/22 10. CE marking 1438 MERAWEX Sp. z o.o. ul. Toruńska 8, 44-122 Gliwice, Poland 1438-CPR-0922 EN 54-4:1997 + AC:1999 + A1:2002 + A2:2006 Power supply unit for Voice Alarm Systems PSU for Voice Alarm Systems...

This manual is also suitable for:

Zdso500-dr3

Table of Contents