Huawei SMU11B X Series User Manual
Huawei SMU11B X Series User Manual

Huawei SMU11B X Series User Manual

Site monitoring unit
Hide thumbs Also See for SMU11B X Series:

Advertisement

Quick Links

SMU11B_X Site Monitoring Unit
V100R023C10
User Manual
Issue
03
Date
2024-05-24
HUAWEI DIGITAL POWER TECHNOLOGIES CO., LTD.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMU11B X Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Huawei SMU11B X Series

  • Page 1 SMU11B_X Site Monitoring Unit V100R023C10 User Manual Issue Date 2024-05-24 HUAWEI DIGITAL POWER TECHNOLOGIES CO., LTD.
  • Page 2 Notice The purchased products, services and features are stipulated by the contract made between Huawei Digital Power Technologies Co., Ltd. and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS"...
  • Page 3: About This Document

    The symbols that may be found in this document are defined as follows. Symbol Description Indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 4: Change History

    Issue 03 (2024-05-24) Updated Table 2-2 Table 2-5. Added Safety Information. Issue 02 (2023-12-15) Updated Overview. Issue 01 (2023-09-01) The issue is the first official release. Software version: eMIMO Embedded Power_V100R023C10 Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 5: Table Of Contents

    5.1 WebUI Common Operations............................. 27 5.1.1 Backing Up Current Settings............................27 5.1.2 Importing a Configuration File............................. 27 5.1.3 Restoring Factory Settings.............................. 28 5.1.4 Upgrading Software................................28 5.1.5 Importing an Individual File............................28 Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 6 5.1.10 Collecting Fault Information............................31 5.1.11 Exporting Maintenance Information........................31 5.2 App Common Operations..............................31 A FAQ............................34 A.1 How Do I Prepare the WebUI Operating Environment................... 34 B Acronyms and Abbreviations....................39 Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 7: Safety Information

    Equipment damage due to force majeure such as earthquakes, floods, volcanic eruptions, debris flows, lightning strikes, fires, wars, armed conflicts, typhoons, hurricanes, tornadoes, and extreme weather conditions ● Operation beyond the conditions specified in this document Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 8: Personal Safety

    D ANGER During operations, use dedicated insulated tools to prevent electric shocks or short circuits. The insulation and voltage resistance must comply with local laws, regulations, standards, and specifications. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 9: General Requirements

    – Trained personnel: personnel who are trained in technology and safety, have required experience, are aware of possible hazards on themselves in Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 10: Environment Requirements

    Ensure that no liquid enters the equipment to prevent faults or short circuits. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 11 All cable holes must be sealed. Seal the used cable holes with sealing putty. Seal the unused cable holes with the caps delivered with the equipment. The following figure shows the criteria for correct sealing with sealing putty. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 12 SMU11B_X Site Monitoring Unit User Manual 1 Safety Information ● After installing the equipment, remove the packing materials such as cartons, foam, plastics, and cable ties from the equipment area. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 13: Overview

    Color Status Description Running Green The SMU is faulty or has no indicator power input. Blinking slowly The SMU is running and (0.5 Hz) communicating with the host properly. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 14: Dip Switch

    When the DIP switch is turned off, the input level is high, and the WiFi function is disabled. When the DIP switch is turned on, the input level is low, and the WiFi function is enabled. Reserved I/O input Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 15: Wiring Terminals

    (ALM2 by alarm when closed. When IO2– default) used as dry contact outputs, the alarm action is as follows: open when normal, closed when alarm.) Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 16: Communications Ports

    Manages site or third-party devices. Provides 12 V power supply for external devices. FE/RS485 10M/100M SNMP Connects to a autonegotiation third-party NMS (pin 1 of the DIP switch: OFF). Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 17 Serial Port Apply to North Access. Figure 2-4 Pins in the COM port Table 2-6 Pin definitions for the COM port Signal Description RS485+ RS485 data, positive RS485– RS485 data, negative Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 18 Table 2-7 Pin definitions for the FE/RS485 port Signal Description Transmit data over northbound FE/ RS485. TX– Receives data over northbound FE. RX– Receive data over northbound RS485. RX– 7, 8 Reserved Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 19: User Interface

    Administrator admin Has all operation Changeme permissions. Engineer engineer Has all permissions Changeme except for changing the administrator password. Operator operator Has the permission to Changeme view parameters only. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 20: Logging In To The Webui

    [SMU local IP address] (such as https:// If IPv6 networking is used, enter https:// [2001::2002]) in the address box of the browser, and then press Enter to enter the login page. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 21: Ui Introduction

    The preset username is admin, and the preset password is Changeme. ----End 3.1.3 UI Introduction Figure 3-3 WebUI homepage (1) Main menu (2) Navigation pane (3) Active alarm bar (4) Language bar 3.2 Site App Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 22: Permission Description

    The mobile phone can properly connect to the Internet. Procedure Step 1 Contact technical support engineers to obtain the latest Site app installation package. Log in to the Huawei support website. NO TE Login address: https://support.huawei.com/enterprise/en/index.html Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 23: Logging In To The Site App

    The login password of the Site app is the same as that of the WebUI. Once the WebUI login password is changed, the Site app login password is changed simultaneously. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 24: Ui Introduction

    User Manual 3 User Interface Step 6 Tap Log In to enter the home screen. ----End 3.2.4 UI Introduction For details about the UI, see Site App Fact Sheet. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 25: Network Management

    Step 3 Set the IP protocol version, IP address, subnet mask, and gateway address on the WebUI. NO TICE If the IP address of the SMU11B is changed on the WebUI, record the IP address for future login. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 26: Logging In To The Neteco

    NetEco IP address:port number for NetEco login (for example, Step 1 Enter https:// https://10.10.10.1:31943) in the address box of the browser and press Enter to go to the NetEco login page. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 27: Network Management (Over Snmp)

    4.2.1 Connecting a Communications Cable Procedure Step 1 Connect a network cable to the FE port on the SMU. Figure 4-3 Connecting a communications cable (1) FE port ----End Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 28: Setting Parameters

    Set this parameter according to the Gateway gateway address provided by the network administrator. a to f, A to F, 0 to 9, and .; (a maximum of 45 characters) ----End Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 29: Setting Snmp Parameters

    SHA and AES. Procedure Step 1 Log in to the WebUI. NO TE The preset username is admin, and the preset password is Changeme. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 30 Confirm MD5/SHA The value must be the same as the MD5/SHA Password password. Proprietary Protocol Select DES, AES-128, AES-192, or AES-256 as required. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 31 The SNMP version here can be different from the version in Step Step 6 In Mib File, click Export to export the MIB file and then import it into the NMS. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 32: Commissioning On The Nms

    ----End 4.2.4 Commissioning on the NMS You can manage the power system on the NMS that is connected over SNMP. For details, see the related documents of the NMS. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 33: Common Operations

    Step 1 Choose Maintenance > Configuration File, enter the decryption password for importing the configuration file in the Import a new configuration file area, select the new configuration file, and click Upload. ----End Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 34: Restoring Factory Settings

    Step 1 Choose System Settings > Basic Settings > Site Config. In the System Individual File area, select a system individual file to be uploaded based on the file storage path and click Upload. ----End Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 35: Changing Password

    Set this parameter based on site requirements. Value range: 1 to 11000 (days). Advance Warning Before Set this parameter based on site requirements. Password Expires (days) Value range: 1 to 90 (days). ----End Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 36: Viewing Active Alarms

    Start Time, and End Time, and click Query to view historical alarms. ----End 5.1.9 Viewing Version Information You can query the SMU version information to facilitate fault diagnosis and check whether the upgrade is successful. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 37: Collecting Fault Information

    5.2 App Common Operations Upgrading Software ● The SMU restarts after the software is upgraded. ● Obtain the latest upgrade package from Huawei technical support. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 38 Collecting Rectifier Fault Information If you cannot rectify the faults based on the alarm handling suggestions, you can collect the fault information and provide the information to Huawei technical support for fault diagnosis. On the Site app: Choose Home > Digital Power > Device > Rectifier Group >...
  • Page 39 On the Site app: Maintenance > Log Export Exporting E-label Information You can view and export e-label information about the power subrack, monitoring board, and rectifier on the app. On the Site app: Maintenance > E-Label Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 40: A Faq

    LAN, do not cancel the proxy server settings. Otherwise, you cannot access the SMU. To cancel proxy server settings, perform the following steps: Open Internet Explorer. Choose Tools > Internet Options. Choose Connections tab, click LAN Settings. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 41 Export historical logs, historical data, statistics, and battery test records. ● Upload system configuration files. ● Download system configuration files. ● Upgrade software. To set Internet Explorer security, perform the following steps: Open Internet Explorer. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 42 Initialize and script ActiveX controls not marked as safe for scripting – Allow previously unused ActiveX controls to run without prompt – Include local directory path when uploading files to a server Figure A-3 Internet Explorer security setting 1 Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 43 Figure A-4 Internet Explorer security setting 2 Figure A-5 Internet Explorer security setting 3 Click OK. Click the Advanced tab, and select Use SSL 3.0, Use TLS 1.0, Use TLS 1.1, and Use TLS 1.2. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 44 SMU11B_X Site Monitoring Unit User Manual A FAQ Figure A-6 Internet Explorer security setting 5 Click OK. Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 45: Acronyms And Abbreviations

    SMU11B_X Site Monitoring Unit User Manual B Acronyms and Abbreviations Acronyms and Abbreviations Control area network Internet Protocol SNMP Simple Network Management Protocol Site monitoring unit User interface Issue 03 (2024-05-24) Copyright © Huawei Digital Power Technologies Co., Ltd.

This manual is also suitable for:

Smu11b02313nsl

Table of Contents