WHEN THE CAMERA PANEL DOES NOT OPEN

When the computer is unable to detect a connection to the Dimâge RD 3000,
the following error message dialog box opens.
In such a case, perform the following troubleshooting operations:
Click the OK button to close the error message dialog box.
1
Click the Close button in the upper right corner of the Digita Desktop
2
control panel to close the application. Mac users should click Exit on
the File menu.
Check the following:
3
• Is the SCSI cable connected properly? (see page 30)
• Has the SCSI cable separated from a connector?
• Has the SCSI cable been cut or damaged?
• Is the SCSI ID number allotted to the Dimâge RD 3000 already in use by another
SCSI device? (see page 24)
• Has the terminator been properly supplied with power? (see page 26)
• Did you turn on the Dimâge RD 3000 before turning on your PC? (see page 36)
• Did you set the Dimâge RD 3000 to PC connect mode before turning on your PC?
(see page 36)
• Has a CF card been inserted into the Dimâge RD 3000? (see page 31)
After verifying that all of the above have been performed properly, fol-
4
low the instructions on pages 36 to 42, open the Digita Desktop control
panel, and once again connect to the Dimâge RD 3000.