Download Print this page

Bionaire BASF1016 - MANUAL 2 Instruction Manual page 2

Hide thumbs Also See for BASF1016 - MANUAL 2:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
BASF1016I05M1 visual.qxd
11/29/05
16:12
Page 4
Figure 1
A
B
C
D
E
F
G
H
R
Q
S
T
U
V
U.K. and IRELAND
PLEASE READ AND SAVE THESE
INSTRUCTIONS
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic safety
precautions should always be taken including
the following:
• Use the fan only for purposes described in the
I
J
K
L
instruction manual.
• To protect against electrical shock, do not
immerse the fan, plug or cord in water or
spray with liquids.
• Close supervision is necessary when any
appliance is used by or near children.
M
• Unplug from the electrical outlet when not in
use, when moving the fan from one location to
another, before putting on or taking off parts
N
and before cleaning.
• Avoid contact with any moving parts
• Do not operate in the presence of explosive
and/or flammable fumes.
• Do not place the fan or any parts near an open
flame, cooking or other heating appliance.
• Do not operate any appliance with a damaged
cord, plug, after the appliance malfunctions, or
O
has been dropped/damaged in any manner.
• The use of attachments not recommended or sold
P
by the appliance manufacturer may cause hazards.
• Do not use outdoors.
• Do not let the cord hang over the edge of a table
or counter, or come into contact with hot surfaces.
• To disconnect from the electrical supply, grip
the plug and pull from the wall outlet. DO NOT
pull on the cord.
• Always use on a dry, level surface.
• Do not operate without the fan grills properly in place.
• This product is intended for household use ONLY
and not for commercial or industrial applications.
• Should the fan stop working, first check the fuse
in the plug (UK only) or fuse/circuit breaker at
the distribution board is operating, before
contacting the manufacturer or service agent.
• If the supply cord or plug is damaged, it must be
replaced by the manufacturer or its service agent or
a similarly qualified person in order to avoid hazard.
MISSING A PART FOR YOUR FAN?
Please call 0800 052 3615 for assistance.
ASSEMBLY INSTRUCTIONS
(Fig. 1)
Base assembly
You will need the base cover (S,T), weighted
insert (U), 1 pole (R) (either can be used as they
are interchangeable) and base nut (V).
IMPORTANT: Unscrew the nut underneath the
Final assembly
weight and discard the removable plastic plug
1. Insert the fan neck joint into the hollow end of
from the centre of the base.
the top pole and slowly turn the neck joint to
lock in place. Be careful to align the cutaway/
1. Insert one pole through the base cover and twist
grooves on the neck joint with the two protruding
pole clockwise to lock in position. Be careful to
raised pieces inside the hollow end of the pole.
align the cutaway grooves on the threaded joint
2. Lastly, insert the tilt adjustment knob (N) into the
(male end) with the two protruding raised pieces
neck joint and tighten until it is securely in place.
inside the hollow end of the base cover.
OPERATING INSTRUCTIONS
2. Now turn the base cover upside down (pole
facing floor) and place the weighted insert into
1. Set the fan base on a dry level surface.
the base cover. The pole threads will be exposed
2. Make sure the Selector (Speed) Control is in
as they protrude through the base insert.
the OFF(0) position. Selector (Speed) Control
3. Hold the pole, base cover and weighted insert
is located on the top of the fan motor housing.
in one hand, place the base nut on the
3. Plug the cord into a suitable 220-240V. AC outlet.
threaded section and hand tighten the base
4. The SPEED is adjusted by turning the Selector
nut with the other hand.
(Speed) Control to the desired setting:
NOTE: Do not use a tool to tighten the base nut.
0 - Off
I
- Low
Pole assembly
II - Med
You will need the second pole (O) (The poles are
interchangeable).
III - High
1. Insert the pole with the threaded joint (male
5. The OSCILLATION control (L) is located on the
end), into the hollow end of the second pole
top of the fan motor housing. To start oscillation,
until both poles meet. Be careful to align the
push the control knob down.To stop oscillation,
cutaway/grooves on the threaded joint (male
pull the control knob up.
end) with the two protruding pieces inside the
ADJUSTMENT
hollow end of the second pole (female end) (P).
Tilt adjustment
2. Now slowly turn the pole with the threaded
1. To change the tilting angle of the fan head,
joint clockwise to lock it securely in place.
simply loosen the tilt adjustment knob (N).
Fan head assembly
2. Move the fan head to the desired angle, then
You are now ready to assemble the fan head.
firmly tighten the knob to lock in place.
1. Position the rear grill (G) over the motor shaft
Height adjustment
(I) making certain that the 2 notches at the top
This fan is equipped with two poles which allow
and bottom of the rear grill, fit over the 2
you to adjust the height of the fan for two height
prongs on the motor housing (J,M).Please
settings. With one pole only, the fan can be used
make sure the rear grill sits securely against
on a table or floor. With both poles fitted it is a
the motor housing.
floor standing fan.
2. Secure the rear grill in its place using the rear
• Small pole 760mm (30")
grill mounting nut (F). Turn this nut clockwise
• Longer pole 910mm (36")
and tighten firmly. Position the large fan blade
• Both poles 1250mm (50")
(E), with the hollowed interior of the blade
facing towards the rear grill, firmly onto the
Floor to table conversion
motor shaft. Align the motor shaft pin with the
1. Remove the fan head by turning it anti-clockwise
recessed groove on the back of the fan blade.
and lifting off the pole. Remove one of the poles,
Be sure that the shaft protrudes through the
(see above for heights available).
front of the blade.
2. Refit the fan head as detailed in "Final assembly".
3. Position the small fan blade (D) into the
hollowed interior of the large blade and press
CLEANING AND MAINTENANCE
firmly into place. Also be sure that the shaft
Follow these instructions to correctly and safely
protrudes from the front of the blade.
care for your Bionaire
4. Secure the fan blades onto the motor shaft by
• Always unplug the fan before cleaning or assembly.
turning the blade cap (C) anti-clockwise and
• Do not allow water to drip on or into the fan
tighten firmly.
motor housing.
5. Centre the front grill (B) by aligning the Bionaire
®
• Be sure to use a soft cloth, moistened with a
logo on the logo plate (A) so that it is horizontal and
mild soap solution.
parallel with the floor. Then, secure the front and
• Do not use any of the following as a cleaner:
rear grills completely together by pushing the front
petrol, thinners or benzene.
grill onto the clips, whilst holding the clips in place.
2
Fan Blade cleaning
(See instructions for fan head assembly)
1. To access the fan blade, remove the front grill
and securing screw.
2. Clean the fan blade, front and rear grills with
a soft moist cloth.
3. Replace the fan blade, tighten screw and
securely fasten the front grill.
Fan head, base and pole cleaning
Using a soft, moist cloth, with or without a mild
soap solution, carefully clean the fan base, pole
and head. Please use caution around the motor
housing area. Do not allow the motor or other
electrical components to be exposed to water.
FAN STORAGE
Your fan can be stored either partially disassembled
or assembled.
It is important to keep it in a safe, dry location.
• If stored disassembled, we recommend using
the original (or appropriately sized) box.
• If stored assembled or partially assembled,
remember to protect the fan head from dust.
FITTING A REPLACEMENT PLUG (UK ONLY)
The wires in this mains lead are coloured in
accordance with the following code:
Blue
-
Neutral
Brown
-
Live
This appliance is fitted with a 13 amp plug. The
fuse should be rated at 3 amps and ASTA
approved to BS1362.
However if the plug is unsuitable, it should be
removed from the supply cord and an
appropriate plug fitted as detailed below:
As the colours of the wires in the mains lead of
this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows:
The wire which is coloured Blue must be
connected to the terminal which is marked with
the letter N or coloured Black.
The wire which is coloured Brown must be
connected to the terminal which is marked with
the letter L or coloured Red.
NB. Neither wire should be connected to the
terminal in your plug which is marked with the
letter E or by the Earth symbol
or coloured
Green or Green and Yellow. If in doubt consult a
fan. Please remember:
®
qualified electrician.
If any other plug is used, a 3 amp fuse must be
fitted either in the plug or adaptor or at the
distribution board.
3

Advertisement

loading