7.5 ton split system

Advertisement

Quick Links

• Condenser Unit manufactured in large
galvanized steel sheet. Air Handling Unit
panels made of double-walled heavy-gauge
galvanized steel with insulation.
• Powder coated paint system: For a long
-lasting professional finish. Additional Modine-
Luvata corrosion resistant spray added for
extra protection.
• Copeland Scroll compressor, which offers
greater protection against liquid damage. More
efficient throughout its operational range;
operates at lower sound and vibration levels
than traditional compressors.
• Easy access to compressors.
COSTERA Series
GXBK090DG4BB
• Serpentin evaporator and condenser made of
• Certified electric motor (PSC motor).
• Compact unit of two cooling circuits.
• Air handling unit with 1" double wall.
• Fan motor coupling with pulley transmission.
• Thermo-acoustic insulation of expanded
• Evaporator fan compartment has easy access
• Stainless steel rivet-nut machine-threaded hex
• Reinforced iron metal base with forklift
www.goodmanmfg.com
Commercial Manual
GXBK090DG4BB & GLCK090DG4AB
7.5 TON SPLIT SYSTEM
copper tubes and copper fins.
polyethylene.
with hinged panels.
head screw-fixed service panels.
openings.
GLCK090DG4AB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COSTERA GXBK090DG4BB and is the answer not in the manual?

Questions and answers

Summary of Contents for Goodman COSTERA GXBK090DG4BB

  • Page 1 Commercial Manual COSTERA Series GXBK090DG4BB & GLCK090DG4AB 7.5 TON SPLIT SYSTEM GXBK090DG4BB GLCK090DG4AB • Condenser Unit manufactured in large • Serpentin evaporator and condenser made of galvanized steel sheet. Air Handling Unit copper tubes and copper fins. panels made of double-walled heavy-gauge •...
  • Page 2: Table Of Contents

    Table of Contents Precautions Technical Specifications Blower Performance Data Unit Dimensions Safety Distance Safe Handling Electric Diagram Suggestions for Installation Suggestions for Ignition Maintenance Recommendations Notes This document will provide relevant information about the equipment. All the information included in this manual is subject to changes without prior notice.
  • Page 3: Precautions

    Precautions In the following document you can find several useful suggestions on the ignition, use and maintenance of your air conditioning split system. Preventive care will help you save time and money during the useful life of the unit. Precaution •...
  • Page 4: Technical Specifications

    Technical Specifications Data corresponding to a certain operation condition based on the AHRI 210/240 or 360 standard. This Rated Load Amps data Notes: (RLA) corresponds to a single compressor. This Locked Rotor Amps data (LRA) corresponds to a single compressor. The information provided in the table can change without prior notice.
  • Page 5 Technical Specifications Data corresponding to a certain operation condition based on the AHRI 210/240 or 360 standard. This Rated Load Amps data Notes: (RLA) corresponds to a single compressor. This Locked Rotor Amps data (LRA) corresponds to a single compressor. The information provided in the table can change without prior notice.
  • Page 6: Blower Performance Data

    Blower Performance Data D a t e 3 0 - 6 - 2 0 2 3 J o b N a m e S u b m i t t e d b y / n o t e s M o d e l F l o w P r e s s u r e...
  • Page 7: Unit Dimensions

    Unit Dimensions GLCK090DG4AB Axial Fan (x2) Copper / Copper Electrical Box Condenser Coil Access Service Valves 1550 Electrical Connection Openning Elect Acce Iron Base Service Access Top View Side View Serv Valve 1550 Axial Fan (x2) Elec Electrical Box 1027 Access Service Valves...
  • Page 8 Unit Dimensions Air Supply Air Supply Double GXBK090DG4BB Electrical Wall [1"] Box Access Electrical Box Access Circuit Connections Circuit Connections Iron Drainage Base [1"] NPT Air Supply Double Drainage Wall [1"] Air Ret [1"] NPT Electrical Air Return Box Access Blower [15"x15"] Blower...
  • Page 9: Safety Distance

    Safety Distance The following minimum free spaces must be observed for the proper performance and capacity of the unit. It is very important that air outlets are not linked in the same duct before a minimum distance of 1.5 meters and preferably at a distance of 2 meters.
  • Page 10: Safe Handling

    Safe Handling Elevation Beam Cable or Chain Separation Bar 15.9 mm Shackle (Each Corner) www.goodmanmfg.com...
  • Page 11: Electric Diagram

    Electric Diagram DIAGRAMA ELÉCTRICO GLCK300DG4AA (220VAC/3PH/60Hz) While performing the electrical installation, the authorized technician must verify that they are complying (POTENCIA) with the electrical circuit of the equipment shown below: GLCK090DG4AB (208V-230V / 3PH / 60Hz) 220V/3PH/60Hz DIAGRAMA ELÉCTRICO CONDESNSADORA DE 7.5 A 10 TR (220VAC/3PH/60Hz) DIAGRAMA ELÉCTRICO GLCK300DG4AA (220VAC/3PH/60Hz) DIAGRAMA ELÉCTRICO GLCK300DG4AA (220VAC/3PH/60Hz) (POTENCIA)
  • Page 12 Electric Diagram While performing the electrical installation, the authorized technician must verify that they are complying with the electrical circuit of the equipment shown below: GXBK090DG4BB (208V-230V / 3PH / 60Hz) DIAGRAMA ELÉCTRICO GXBK300DG4BA (220V/3PH/60Hz) 220V/3PH/60Hz 220Vac 24Vac Recommended connection for capacitor signal.
  • Page 13: Suggestions For Installation

    Suggestions for Installation The conditions that must be taken into account in general before installing the equipment: The works on the units must be carried out only by professionals. Do not connect the power supply until all the work is finished. Considerations to take into account 1.
  • Page 14: Suggestions For Ignition

    Suggestions for Ignition Briefly, the steps for the ignition and commissioning of the equipment are as follows (only an authorized technician can do it): Never do work without the help of professionals. Before making any connection, be sure not to have connected or energized the equipment or sources of equipment until all the work is finished.
  • Page 15: Maintenance Recommendations

    Maintenance Recommendations With due maintenance and care, the air conditioning unit will work successfully. Before maintaining, consider the following security precautions: WARNING! To prevent damage to the equipment and personal injury or death, disconnect all electricity supply to the equipment before removing access panels to perform some maintenance work. Disconnect electricity to the interior and exterior units.
  • Page 16: Notes

    Notes www.goodmanmfg.com...
  • Page 17 In accordance with its continuous progress policy and product improvement, Goodman reserves the right to make changes without prior notice. www.goodmanmfg.com...

This manual is also suitable for:

Costera glck090dg4ab

Table of Contents