Beep Codes - NEC VERSA FX Manual

Hide thumbs Also See for VERSA FX:
Table of Contents

Advertisement

Message
Off Board Parity Error
On Board Parity Error
Parity Error ????

Beep Codes

Fatal errors that occur during POST are communicated through a series of beeps. All
beep code errors, except beep code 8, are fatal errors and do not allow the system to
continue to boot.
If beep codes occur during POST, check the items in the Problem Checklist (at the start
of this chapter), verify that all the hardware is set up properly and securely connected,
and try rebooting. If you still get a beep code, go to the section "If You Need
Assistance" at the end of this chapter.
Beep Codes are listed in the table that follows.
Number of
Beeps
1
2
3
4
10-6 Solving System Problems
Post Error Messages
Resolution
Parity error in an expansion slot. Contact your NECC
service representative to be sure that the memory
module is installed correctly.
The error format is:
OFF BOARD PARITY ERROR
ADDR(HEX) = (XXXX)
XXXX is the hex address where the error occurred.
Parity error in system board memory. Contact your
NECC service representative for service.
Parity error in system memory at an unknown address.
Contact your NECC service representative for service.
Beep Codes
Error
Refresh Failure
Parity Error
Base 64 KB Memory
Failure
Timer Not Operational
Description
The memory refresh circuitry on the
motherboard is faulty.
Parity error in the first 64 KB of
memory.
Memory failure in the first 64 KB.
Memory failure in the first 64 KB of
memory or Timer 1 on the
motherboard is not functioning.