32
STEP
DESCRIPTION
24
Display Filter Factor
25
Process Filter Factor
26
Process Value Output
Retransmission
(If Pout =0 then Pou and
PoL will not be displayed)
27
Process Output
Upper Value
28
Process Output
Lower Value
29
Chart Range
Upper Value
30
Chart Range
Lower Value
31
Proportional
Output 1 Action
on Error Condition
(If out1= 0,1,2 then
P1EC will not be displayed)
32
Proportional
Output 2 Action
on Error Condition
(If out2 = 0,1,2,7 then
P2EC will not be displayed)
33
Pen Action on
Error Condition
Pressing the SCROLL key with the PAEC parameter value displayed in the Pen 1 window will
advance the display of a single pen instrument to the unit parameters. Pressing the SCROLL
key with the PAEC parameter displayed in the Pen 1 window of a two pen instrument will
advance the display to be PEns in the Pen 2 window. The Pen 2 Program mode parameter
selections can be made now. Pressing the SCROLL key with the PAEC parameter value
displayed in the Pen 2 window will cause the display to advance to the unit parameters
displayed in the Pen 1 window.
34
Relay A Assignment
DISPLAY AVAILABLE
CODES SETTINGS
dFF
1 to 20
1= no filtering
(number of values averaged)
PFF
Same selection as dFF
Pout
0=Not selected
1=Selected
Pou
-9999 to 9999
PoL
-9999 to 9999
Cru
-9999 to 9999
CrL
-9999 to 9999
P1EC
0 to 100%
P2EC
0 to 100%
PAEC
0 or 1
0 = Pen goes to 0 % of chart
1 = Pen goes to 100 % of chart
UNIT PARAMETERS
rLyA
0 to 14
1=Assigned to Alarm 1-Pen 1
2=Assigned to Alarm 2-Pen 1
3=Assigned to Alarm 1-Pen 2
4=Assigned to Alarm 2-Pen 2
5=Assigned to Output 1-Pen 1
6=Assigned to Output 2-Pen 1
7=Assigned to Output 1-Pen 2
8=Assigned to Output 2-Pen 2
9=Assigned to Event 1
10=Assigned to Event 2
11=Assigned to Event 3
12=Assigned to Event 4
13=Assigned to Event 5
14=Assigned to Event 6
FACTORY
YOUR
SETTING
SETTING
1
1
0
2000
0
200
0
0
0
1
0