Duco DucoBox Silent Installation Manual

Hide thumbs Also See for DucoBox Silent:

Advertisement

Quick Links

DucoBox Silent
ENGLISH
Product version 17xxxx and above
Installation guide
Video instructions
www.duco.tv
L2000651 (Revision P | 24.01.2025)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DucoBox Silent and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Duco DucoBox Silent

  • Page 1 DucoBox Silent ENGLISH Product version 17xxxx and above Installation guide Video instructions www.duco.tv L2000651 (Revision P | 24.01.2025)
  • Page 2: Table Of Contents

    DUCO, HANDELSSTRAAT 19 VEURNE, B-8630 Vero Duco - Handelsstraat 19 - 8630 Veurne - Belgium tel +32 58 33 00 33 - fax +32 58 33 00 44 - info@duco.eu - www.duco.eu L2000651 Installation guide for DucoBox Silent (Revision P | 24.01.2025)
  • Page 3: Introduction

    ENGLISH 01 Introduction Congratulations on your DucoBox Silent, the quietest box in Europe! The DucoBox Silent performs two functions in a DUCO Demand-Controlled Natural Ventilation System: On the one hand it is the extractor fan that exhausts stale air with excessive CO content or humidity�...
  • Page 4: Product Sheet

    120,2 86,8 50,8 electricity/a) cold 3355 4290 5536 Annual heating saved (AHS) 1715 2193 2830 average in (kWh primary energy/a) warm 1280 Ecodesign Delegated regulation (EU) n° 1253/2014 (Duco V20200701) L2000651 Installation guide for DucoBox Silent (Revision P | 24.01.2025)
  • Page 5 100,9 72,9 42,6 electricity/a) cold 3355 4290 5536 Annual heating saved (AHS) 1715 2193 2830 average in (kWh primary energy/a) warm 1280 Ecodesign Delegated regulation (EU) n° 1253/2014 (Duco V20200701) L2000651 Installation guide for DucoBox Silent (Revision P | 24.01.2025)
  • Page 6 89,6 64,7 37,8 electricity/a) cold 3355 4290 5536 Annual heating saved (AHS) 1715 2193 2830 average in (kWh primary energy/a) warm 1280 Ecodesign Delegated regulation (EU) n° 1253/2014 (Duco V20200701) L2000651 Installation guide for DucoBox Silent (Revision P | 24.01.2025)
  • Page 7: Regulations And Safety Instructions

    • Bends in the ducts immediately upstream of the fan unit. • The DucoBox Silent must not be connected to a (motorless) extractor hood or tumble dryer. Take care to ensure that the electrical power supply is a 230 V, single- It ought to be impossible to touch the fan by hand�...
  • Page 8: Mounting

    10 UNMISSABLE TIPS connections Keep down restriction� A non-return flap is The smooth running of your Duco ventilation system is totally dependent on the choice and the quality of implementation of the duct system! required when discharging into a manifold�...
  • Page 9: Wiring

    HIGH INST the DucoBox� 05.B Wiring diagram The DucoBox Silent communicates with components through a wireless (RF) DUCO RF connection� RF components have a maximum free-field range of 350 metres� This Power supply 230 VAC distance will be much less in a building because of obstacles� Therefor you will need Wiring 1,5 mm²...
  • Page 10: Additional Control Options

    This can be done using the Duco Network Tool*� This us- er-friendly software also enables problems in the system to be pinpointed� The Duco Network Tool is issued to every installer after attending a free training course at the Duco Academy*� Please refer to our website or your DUCO dealer for further information�...
  • Page 11: 07�C Led Indications

    (see table in the next section)� ‘Installer mode’ can be activated by pressing the DucoBox Silent Connect ‘INST’ button (see drawing in section "05�A Connections & buttons" on page 9)� When the LED on the controller starts flashing green, 'Installer mode' is active� Press ‘INST’ again to return to ‘User mode’...
  • Page 12: 07�E Pairing Components

    DucoBox� Once all components have been paired, ‘Installer mode’ can be deactivated by tapping ‘INST’ on the DucoBox Silent� The LEDs on all components will stop flashing� Please refer to the manual with the components for more detailed information�...
  • Page 13: 07�G Tips

    • Restore factory settings for the DucoBox and all paired components (AS FROM DucoBox version 18xxxx): Long-press ‘INST’ and ‘ENTER’ if not in ‘Installer mode’. The network remains in place� • Use the Duco Network Tool to read out information from components� 08 Air calibration For the system to operate correctly, the air volume must be adjusted�...
  • Page 14 LEDs of the 'AUTO' button on the User Controllers / Room Sensors turn white, and the LED on the DucoBox turns white� * Depending on the software version of the User Controller� L2000651 Installation guide for DucoBox Silent (Revision P | 24.01.2025)
  • Page 15: 08�B Checking

    All warranty conditions concerning the DucoBox and DUCO's ventilation systems can be found on the DUCO website� Complaints must be made in writing to DUCO by the installer or the DUCO distribution point, clearly stating the complaint and the order/invoice number with which the products were delivered� To do so, please fill out the complaint registration form, found on the DUCO website, mentioning the serial number and send it to service@duco�eu�...
  • Page 16 Installed by: L2000651 Document last modified on 24.01.2025 (revision P)

Table of Contents