Duco DucoBox Silent Series Installation Manual

Duco DucoBox Silent Series Installation Manual

Hide thumbs Also See for DucoBox Silent Series:

Advertisement

DucoBox Silent
ENGLISH
Product version 17xxxx and above
Installation guide
Step by step
duco.tv
instructions
L2000651 (Revision N | 13.07.2020)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DucoBox Silent Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Duco DucoBox Silent Series

  • Page 1 DucoBox Silent ENGLISH Product version 17xxxx and above Installation guide Step by step duco.tv instructions L2000651 (Revision N | 13.07.2020)
  • Page 2: Table Of Contents

    DUCO, HANDELSSTRAAT 19 VEURNE, B-8630 Vero Duco - Handelsstraat 19 - 8630 Veurne - Belgium tel +32 58 33 00 33 - fax +32 58 33 00 44 - info@duco.eu - www.duco.eu L2000651 Installation guide for DucoBox Silent (Revision N | 13.07.2020)
  • Page 3: Introduction

    ENGLISH 01 Introduction Congratulations on your DucoBox Silent, the quietest box in Europe! The DucoBox Silent performs two functions in a Duco De- mand-Controlled Natural Ventilation System: On the one hand it is the extractor fan that exhausts stale air with excessive CO content or humidity�...
  • Page 4: Product Sheet

    120,2 86,8 50,8 electricity/a) cold 3355 4290 5536 Annual heating saved (AHS) 1715 2193 2830 average in (kWh primary energy/a) warm 1280 Ecodesign Delegated regulation (EU) n° 1253/2014 (Duco V20200701) L2000651 Installation guide for DucoBox Silent (Revision N | 13.07.2020)
  • Page 5 100,9 72,9 42,6 electricity/a) cold 3355 4290 5536 Annual heating saved (AHS) 1715 2193 2830 average in (kWh primary energy/a) warm 1280 Ecodesign Delegated regulation (EU) n° 1253/2014 (Duco V20200701) L2000651 Installation guide for DucoBox Silent (Revision N | 13.07.2020)
  • Page 6 89,6 64,7 37,8 electricity/a) cold 3355 4290 5536 Annual heating saved (AHS) 1715 2193 2830 average in (kWh primary energy/a) warm 1280 Ecodesign Delegated regulation (EU) n° 1253/2014 (Duco V20200701) L2000651 Installation guide for DucoBox Silent (Revision N | 13.07.2020)
  • Page 7: Fitting

    10 UNMISSABLE TIPS connections Keep down restriction� A non-return flap is The smooth running of your Duco ventilation system is totally dependent on the choice and the quality of implementation of the duct system! required when discharging into a manifold�...
  • Page 8: Wiring

    350 m, free field (less Maximum distance are forwarded automatically via no more than one other component (= hop point)� through obstacles) Please refer to information sheet RF communication (L8000018) at www�duco�eu Up to 25 wireless Maximum number for further information�...
  • Page 9: Additional Control Options

    This can be done using the Duco Network Tool*� This us- er-friendly software also enables problems in the system to be pinpointed� The Duco Network Tool is issued to every installer after attending a free training course at the Duco Academy*� Please refer to our website or your Duco dealer for further information�...
  • Page 10: 06�B Installer / User Mode

    ENGLISH 06.B Installer / User mode To add components to the network, remove or replace, the system should be put in ‘Installer mode’� The LED on each component indicates the active mode of the component (see table in next section)� ‘Installer mode’ can be activated by pressing the DucoBox Silent ‘INST’ button (see drawing in section "04�A Connections & but- tons"...
  • Page 11: 06�E Pairing Components

    ENGLISH 06.E Pairing components Never pair more than one system with RF components at the same time. If you do so, a component in the wrong network could be paired, e.g. in the neighbours’ DucoBox. Example of a pairing sequence Pairing components on the DucoBox Silent Activate ‘Installer mode’...
  • Page 12: Air Calibration

    The system needs to be configured for it to work correctly� This will ensure its operation is as quiet as possible and energy-efficient� See under the Tools heading at www�duco�eu for information about determining ventilation flow rates� 07.A Air calibration procedure for DucoBox Silent The air calibration procedure must be carried out on a calm day (no more than wind force 2: leaves rustling, feel- ing the wind in one’s face)�...
  • Page 13 ENGLISH Press ‘HIGH’ or ‘LOW’ to activate the configuration mode for 30 minutes� Then close the cover firmly. Which configuration mode should I choose? Air calibration using 'HIGH' Air calibration using 'LOW' This method is standard and has the This method offers a boost mode Button HIGH lowest consumption�...
  • Page 14: 07�B Checking

    All warranty conditions concerning the DucoBox and Duco's ventilation systems can be found on the Duco website� All complaints are to be reported to Duco by the Duco distributor with a clear description and the order/invoice number under which the products were delivered� In order to register the complaint, please use the complaint registration form found on the Duco website and the product's serial number in your message to service@duco�eu�...
  • Page 15 ENGLISH L2000651 Installation guide for DucoBox Silent (Revision N | 13.07.2020)
  • Page 16 Installed by: L2000651 Document last modified on 13.07.2020 (revision N)

Table of Contents