Installation, connection, maintenance and repairs are to be carried out by an accredited installer� The electronic components of this product may be live� Avoid contact with water� DUCO, HANDELSSTRAAT 19 VEURNE, B-8630 VERO DUCO - Handelsstraat 19 - 8630 Veurne - Belgium tel +32 58 33 00 33 - info@duco.eu - www.duco.eu L2000641 Installation guide for DucoBox Silent Connect (Revision I | 19.10.2023)
ENGLISH 01 Introduction Congratulations on your DucoBox Silent Connect, the quietest box in Europe! The DucoBox Silent Connect performs two functions in a DUCO Demand-Controlled Natural Ventilation System: On the one hand it is the extractor fan that exhausts stale air with excessive CO content or humidity�...
(p.e. for ducts placed in floor screed). Make sure that the total counter pressure in the ducts is as low as possible (preferably ≤ 150Pa) and that the airspeed in every duct does not exceed 3 m/s. L2000641 Installation guide for DucoBox Silent Connect (Revision I | 19.10.2023)
INST 04.B Wiring diagram The DucoBox Silent Connect is able to communicate with DUCO slave components via a wireless (RF) or wired link� Both types of communication can be combined in one system� Communication with non-DUCO components is possible via the switch sensor�...
05 Additional control options 05.A Box sensors Box sensors can be built into a DucoBox Silent Connect and provide and/or humidity measurement in an air duct� A DucoBox Silent Connect can contain a maximum of one CO and one Humidity...
(see table in next section)� ‘Installer mode’ can be activated by pressing the DucoBox Silent Connect ‘INST’ button (see drawing in section "04�A Connections & buttons" on page 8�) Once the LED on the master unit starts flashing, it means that ‘Installer mode’ is active� Press ‘INST’ again to return to ‘User mode’...
(applies for 4 occupants or more)� Press ‘LOW’ or ‘HIGH’ respectively again until the LED pattern matches the correct number of occupants� INST Press the ‘INST’ button to exit ‘Installer mode’� L2000641 Installation guide for DucoBox Silent Connect (Revision I | 19.10.2023)
Deactivate ‘Installer mode’ by pressing the 4 buttons on a paired control simultaneously (or using the palm of your hand on a control featuring touch buttons)� The LED will turn white� L2000641 Installation guide for DucoBox Silent Connect (Revision I | 19.10.2023)
• Restoring factory settings of the DucoBox and all registered components (AS FROM DucoBox version 18xxxx): Long press 'INST' and 'ENTER' when not in 'Installer mode'� The network will be preserved� • Use the Duco Installation App or the Duco Network Tool to read out information from components� 07 Air calibration The system needs to be configured for it to work correctly�...
Page 14
LEDs light up white briefly and then turn yellow again� • Press ‘ENTER’ in the DucoBox and then immediately close the lid on the Duco- Box� If the lid was not closed, you can pull the plug out of the power socket for a few seconds after closing the lid in order to reboot the DucoBox�...
All warranty conditions concerning the DucoBox and DUCO's ventilation systems can be found on the DUCO website� All complaints are to be reported to DUCO by the DUCO distributor with a clear description and the order/invoice number under which the products were delivered� To do so, please fill out the complaint registration form, found on the DUCO website, mentioning the serial number and send it to service@duco�eu�...
Page 16
ENGLISH Installed by: L2000641 Document last modified on 19.10.2023 (revision I) L2000641 Installation guide for DucoBox Silent Connect (Revision I | 19.10.2023)
Need help?
Do you have a question about the DucoBox Silent Connect and is the answer not in the manual?