1. Connection & buttons Fan 1 Blue Yellow Red White Duco Switch Wired Contact Duco PE (green/ Network yellow) Tool Power N (blue) 230 VAC L (brown) Duco Connectivity Board Temperature sensors Antenna Bypass 2 Pressure sensors HIGH INST Bypass 1...
DucoBox and some control components indicate the current ventilation percentage (bright = 100% ventilation). Blue Visualisation of component (e.g. when changes are implemented via the master) DucoBox (master): DucoBox (master): Magenta Software update via Duco Connectivity Update completed Board or Duco Installation Kit...
Page 4
Connecting air ducts When connecting the ductwork, it must be taken into account whether it is a left-hand or right-hand configuration. Air duct connections are also indicated on the DucoBox Energy Premium by means of stickers. LEFT-HAND setting RIGHT-HAND setting...
3. Startup Switch on the power to the DucoBox Energy Premium (plug into power socket). When the DucoBox Energy Premium starts up for the first time, you will be asked to enter a few basic settings. Navigate using the arrow keys ( ) and confirm using enter ( ).
Page 6
You need to take account of zone designations if you are utilising an integrated 2-zone system. Zone 1 is the bevelled side of the DucoBox Energy Premium in each case. Pairing control components with the DucoBox Energy Premium 1. Activate advanced mode: •...
Page 7
3. Start the WIZARD. The DucoBox Energy Premium will automatically detect whether it is a 1-zone or a 2-zone system. The system now enables control components to be paired with the entire system (step 4), zone 1 (step 5) or zone 2 (step 6).
Page 8
For 2-zone system only Pair the desired control components with zone 1. This could be the daytime zone (living room, office, etc.) Then confirm by pressing enter ( ). For 2-zone system only Pair the desired control components with zone 2. This could be the night zone, for example (bedrooms).
Page 9
Tips: The network can be wiped or a full reset of the DucoBox Energy Premium can be carried out in the event of any problems. To do this, refer to the following functions under the INSTALLATION menu (visible only after activating advanced mode).
Page 10
5. Pre-setting vents In order to calibrate the air supply and extraction correctly, these vents must be set depending on the situation in accordance with the table below. When using DucoVent Design vents always leave the outer ring in place for an acoustic effect.
Page 11
Close all windows and doors. Ensure that all duct openings in the DucoBox Energy Premium are fully closed and that the lid of the DucoBox Energy Premium is closed. Avoid air leaks in the ventilation ducts. Open all interior doors between the various zones.
Page 12
The calibrated flow rates can be checked at the various vents once adjustment and calibration have been completed. Do this by going into advanced mode and select “CALIBRATION → VERIFY HIGH LEVEL”. The DucoBox Energy Premium will now ventilate for 30 minutes at its calibrated ventilation setting.
Page 13
8. Electronical Installation Removing / replacing components Removing paired components from the network or replacing is only possible within 30 minutes after the component is paired or restarted. Restarting can be done by disconnecting the power for a moment. After a time-span of 30 minutes, remove and replace operations are ignored. Removing a component Activate ‘Installer mode’...
Page 14
Perform software updates Requirements for use A Duco Installation Kit is required to use the Duco Installation App. This kit connects to the DucoBox via a local Point to Point Wi-Fi connection. The app and Installation Kit work with the following DucoBox models: DucoBox Silent Connect, DucoBox Focus,...
Page 15
Download the Duco Installation App for free on Google Play or in the App store: Did you know that you get one year extra warranty when you correctly adjust a DucoBox via the Duco Installation App?