Kaysun KHP-BI 4 DVN Installation & Owner's Manual
Kaysun KHP-BI 4 DVN Installation & Owner's Manual

Kaysun KHP-BI 4 DVN Installation & Owner's Manual

Aquantia bibloc outdoor unit

Advertisement

Quick Links

INSTALLATION & OWNER'S
KHP-BI 4 DVN
KHP-BI 12 DVN
KHP-BI 12 DTN
Thank you very much for purchasing our product.
Before using your unit, please read this manual carefully and keep it for future reference.
MANUAL
KHP-BI 6 DVN
KHP-BI 14 DVN
KHP-BI 14 DTN
Aquantia Bibloc
Outdoor Unit
KHP-BI 8 DVN
KHP-BI 16 DVN
KHP-BI 16 DTN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KHP-BI 4 DVN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kaysun KHP-BI 4 DVN

  • Page 1 INSTALLATION & OWNER’S MANUAL Aquantia Bibloc Outdoor Unit KHP-BI 4 DVN KHP-BI 6 DVN KHP-BI 8 DVN KHP-BI 12 DVN KHP-BI 14 DVN KHP-BI 16 DVN KHP-BI 12 DTN KHP-BI 14 DTN KHP-BI 16 DTN Thank you very much for purchasing our product.
  • Page 2: Table Of Contents

    CONTENTS PAGE CAUTION 1. PRECAUTIONS ..............1 New Refrigerant Heat Pump Installation 2. ACCESSORY AND REFRIGERANT ........2 THIS HEAT PUMP ADOPTS THE NEW HFC REFRIGERANT 3. BEFORE INSTALLATION ............ 2 (R410A)WHICH DOES NOT DESTROY OZONE LAYER. 4. IMPORTANT INFORMATION REGARDING THE ●...
  • Page 3: Accessory And Refrigerant

    ● Do not modify this unit by removing any of the safety Required tools for installation work: guards or by by-passing any of the safety interlock Screw driver switches. Exposure of unit to water or other moisture Gauge manifold before installation may cause a short-circuit of Hole core drill(65mm) (Charge hose: R410A special electrical parts.
  • Page 4: Important Information Regarding The Refrigerant Used

    4 IMPORTANT INFORMATION Make sure there is enough room to do the installation REGARDING THE ■ Turn the air outlet side toward the building's wall, fence or screen. REFRIGERANT USED This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent gases into the atmosphere. Strong wind Refrigerant type: R410A...
  • Page 5: Outdoor Unit Installation

    6 OUTDOOR UNIT INSTALLATION 6.1 Installation place Please keep away from the following place, or malfunction of the machine may be caused: 1) There is combustible gas leakage. 2) There is much oil (including engine oil) ingredient. 3) There is salty air surrounding(near the coast) 4) There is caustic gas (the sulfide, for example) existing in the air (near a hotspring) 5) A place the heat air expelled out from the outdoor unit can...
  • Page 6: Water Outlet

    6.4 Water Outlet 2) Parallel connect the two units or above Four condensed water outlets on the chassis for selection display as the follow figure: >300 >600 >2000 Fig. 6-6 3) Parallel connect the front with rear sides Water Outlet >2000 >500 >3000...
  • Page 7: Install The Connecting Pipe

    7 INSTALL THE CONNECTING PIPE Fat pipe Check whether the differance in height between the indoor unit and outdoor unit, the length of refrigerant pipe, and the number of the bends meet the following requirements: Front out pipe Side out pipe Back out pipe Undersurface out pipe 7.1 Refrigerant piping...
  • Page 8: Connecting Method

    7.4 Connecting method 7.5 Remove Dirt or Water in the Pipes Indoor Unit Outdoor Unit Make sure there is no any dirt or water before connectiong the piping to the outdoor units. Wash the pipes with high pressure nitrogen, never use refrigerant of outdoor unit.
  • Page 9: Electrical Wiring

    8 ELECTRICAL WIRING Outdoor Unit CAUTION 3x0.75mm ● Please select power source for indoor unit and outdoor Power Supply 3x4.0mm (3-shield wire) unit respectively. Power Supply 3x2.5mm ● The power supply has specified branch circuit with leakage protector and manual switch. ●...
  • Page 10: Switch Box Main Components

    8.3 Switch box main components The image shown here is indicative only. If there is inconsistency between the image and the actual product, the actual product shall govern. 8.3.1 Switch box main components (1-phase 4\6\8kW) 1-phase 4~8kW PCB A To main board (CN101,CN105) Compressor connection port U V W (U,V,W) Input port N for IPM module(N) Input port P for IPM module(P)
  • Page 11 1-phase 4~8kW PCB B PCB A Rectifier bridge input port L Th temperature sensor port Hydraulic compartment input port2 Pressure sensor port Rectifier bridge input port N Wire controller port Power supply N P/N/+18V port Power supply L To IPDU/PFC Transformer output port DC fan port BLACK: T3 temperature sensor port...
  • Page 12 8.3.2 Switch box main components (1-phase, 10/12/14/16kW) 1-phase 10~16kW PCB A 1 Reserved(CN2) Power Supply Of U Phase For Compressor(U) 10 Input Port N For Pfc Module(VIN-N) 2 Input Port N For Ipm Module(N) Output Port N Of Pfc Module(N_1) 11 Input Port P Foripm Modele(P) 3 Power Supply Of W Phase For Compressor(W) Output Port P Of Pfc Module(P_1)
  • Page 13 8.3.2 Switch box main components (1-phase, 10/12/14/16kW) 3-phase 12~16kW PCB A 1 Power supply L3(L3) 7 Power supply for main control board(CN19) 2 Power supply L2(L2) 8 Power filtering L1(L1’) 3 Power supply L1(L1) 9 Power filtering L2(L2’) 4 Power supply N(N) 10 Power filtering L3(L3’) 5 Ground wire(GND_1) 11 Ground wire(GND_2)
  • Page 14: Test Running

    3-phase 12~16kW PCB C 4 5.1 5.2 6.1 21 20 Power supply for the main PCB(CN250) 10 Port for electrical expansion value(CN22) 18 Reserved(CN68) Port for pressure sensor(CN36) 11 Port for power supply(CN41) 19 Port for down fan(CN19) Port for sunction temperature sensor(CN4) 12 Power supply for hydro-box control 20 Port for up fan(CN17) Port for discharge temperature sensor(CN8)
  • Page 15: Turn Over To Customer

    Indoor Unit WARNING Outdoor Unit Ask your dealer for installation of the heat pump. ● Incomplete installation performed by yourself may result in a water leakage, electric shock, and fire. Ask your dealer for improvement, repair, and maintenance. ● Incomplete improvement, repair, and maintenance may result in a water leakage, electric shock, and fire.
  • Page 16: Operation And Performance

    If the refrigerant leaks in the room, contact with a fire of a ● Never expose little children, plants or animals directly to burner, a heater or a cooker may result in a harmful gas. the air flow. Adverse influence to little children, animals and plants may ●...
  • Page 17: Heating Capacity

    13 MALFUNCTION CODE OF ● Mishandling in operation: If mishandling happens because of lighting or mobile wireless, OUTDOOR UNIT please shut off the manual power switch, and turn on again, thenpush the ON/OFF button. 13.1 Error codes NOTE When a safety device is activated, an error code will be displayed on When the protection equipment starts, please shut down the the user interface.
  • Page 18 Code Discription Corrective action Check that the unit is operating within its operating Heat mode fan is running in A region for 10 minutes range, contact your local dealer Restart the unit, if the error occurs again, contact Twice H6 in 10 minutes your local dealer Check that the unit is operating within its operating PFC module fault...
  • Page 19: Following Symptoms Are Not

    14 FOLLOWING SYMPTOMS ARE 15 TROUBLE SHOOTING NOT HEAT PUMP TROUBLES If one of the following malfunctions occur, stop operation, shut Symptom 1: The system does not operate off the power, and contact with your dealer. The operation lamp is flashing rapidly (twice every second) This The heat pump does not start immediately after the ON/OFF lamp is still flashing rapidly after turn off the power and turn on button on the romote controller is pressed.
  • Page 20 Symptoms Causes Solution Power failure. ● Power switch is off. Wait for the comeback of power. ● ● Fuse of power switch may have Switch on the power. ● ● Unit does not start burned. ReplLocation: ● Batteries of remote controller Replace the batterises or check the ●...
  • Page 21: Technical Specifications

    16 TECHNICAL SPECIFICATIONS KHP-BI 4 DVN KHP-BI 12 DVN KHP-BI 12 DTN Model (Capacity mark) KHP-BI 6 DVN KHP-BI 8 DVN KHP-BI 14 DVN KHP-BI 14 DTN KHP-BI 16 DVN KHP-BI 16 DTN Power supply 220-240V~ 50Hz 380-415V3N~50Hz Rated power input 2.7kW...
  • Page 22: Important Information For The Used Refrigerant

    This product has the fluorinated gas which is listed in kyoto protocol it is forbidden to release to air. Refrigerant type: R410A; Volume of GWP: 2088; GWP=Global Warming Potential Factory charge Model tonnes CO Refrigerant/kg equivalent KHP-BI 4 DVN 2.50 5.22 KHP-BI 6 DVN 2.50 5.22 KHP-BI 8 DVN 2.80 5.85 KHP-BI 12 DVN 3.90...
  • Page 23 MD16IU-007FW 16125300000939...