Download Print this page

Advertisement

OWNER'S MANUAL
KMF-200 DN4
KMF-224 DN4
Thank you very much for purchasing our air conditioner,
Before using your air conditioner, please read this manual carefully and keep it for future reference.
Amazon Unitario DN4
KMF-260 DN4
KMF-280 DN4
KMF-335 DN4

Advertisement

loading

Summary of Contents for Kaysun Amazon Unitario DN4

  • Page 1 OWNER'S MANUAL Amazon Unitario DN4 KMF-200 DN4 KMF-260 DN4 KMF-335 DN4 KMF-224 DN4 KMF-280 DN4 Thank you very much for purchasing our air conditioner, Before using your air conditioner, please read this manual carefully and keep it for future reference.
  • Page 2 16126000A19882 V.D...
  • Page 3 This air conditioner comprises an indoor unit, outdoor unit, and a connection pipe. Indoor unit Outdoor unit Air outlet Air inlet Fig.1 Fixing support Refrigerant pipe connector Connection pipe NOTE All the pictures in this manual are for explanation purpose only. They may be slightly different from the air conditioner you purchased(depend on model).
  • Page 4: Table Of Contents

    CONTENTS PAGE Never use a flammable spray such as hair spray, lacqueror paint near the unit. It may cause a fire. IMPORTANT SAFETY INFORMATION............1 Never touch the air outlet or the horizontal blades while OPERATION RANGE..................3 the swing flap is in operation. OPERATION AND PERFORMANCE............3 Fingers may become caught or the unit may break down.
  • Page 5: Operation Range

    Do not operate the air conditioner with a wet hand. The temperature of refrigerant circuit will be high, please An electric shock may happen. keep the interconnection cable away from the copper tube. Do not touch the heat exchanger fins. Poor environmental conditions, the appliance should be These fins are sharp and could result in cutting injuries.
  • Page 6: Operation And Performance

    2.1 Short-circuit ratio statement Other heating equipment is suggested to be used together when outdoor temperature is too low. We declare the model KMF(200,224,260,280,335)DN4 In some extreme cold upland that buy another inddoor unit This equipment complies with IEC 61000-3-12 provided that the equipped electrical heater will obtain better performance.(Refer short-circuit power Ssc is greater than or equal to 6280232W at the to indoor unit owner’s manual for details)
  • Page 7: Malfunction Code Of Outdoor Unit

    MALFUNCTION CODE OF OUTDOOR UNIT Table 4-1 Failure or Protection Type Fault Code Recovery Mode Communication error between main board and Recoverable compressor drive board DC bus voltage error Recoverable Inverter-module protection Recoverable Irrecoverable 3 times of P2 protection in 30 minutes Qty.
  • Page 8: Following Symptoms Are Not Air Conditioner Troubles

    5. FOLLOWING SYMPTOMS ARE NOT AIR Symptom 4.2: Indoor unit, outdoor unit CONDITIONER TROUBLES A continuous low hissing sound is heard when the system is in operation. Symptom 1: The system does not operate This is the sound of refrigerant gas flowing through both indoor and outdoor units.
  • Page 9 Table 6-1 Symptoms Causes Solution Power failure. Wait for the comeback of power. Power switch is off. Switch on the power. Fuse of power switch may have burned. ReplLocation: Unit does not start Unit does not start Batteries of remote controller exhausted Replace the batterises or check the or other problem of controller.
  • Page 10: Maintenance And Pepair

    6.2 Troubles and causes of remote controller Before asking for serving or repairing , check the following points. (see in Table 6-2) Table 6-2 Symptoms Causes Solution Check whether the MODE When the automatic mode is indicated on the display is selected, the air conditioner will "AUTO"...
  • Page 11 7.1 Maintenance after Unit has been Shut Down ▪ For equipment that contains fluorinated greenhouse gases in for a Long Period quantities of 5 tonnes of CO2 equivalent or more,but of less than 50 tonnes of CO2 equipment,at least every 12 months, or where a For example, in early summer or winter.