LED codes Initial Setup Requirements First, ensure you have all necessary components: ● Sensedge Go devices ● Kaiterra Gateway ● Kaiterra Go app, available in the App Store Play Store. Gateway Setup 1. Attach the gateway antenna to the gateway 2.
Page 2
Device Placement Monitors should be placed in the breathing zone, a height range between 3 and 6 ft (0.9 and 1.8 m) above the floor. Monitors should be at least 16 ft (5 m) away from operable windows, fresh air diffusers, and air purifiers.
Page 3
6. Allow 24 hours for the adhesive bond to fully cure. Device Configuration 1. Open the Kaiterra app on your mobile device 2. Follow the in-app instructions to add your Sensedge Go 3. Log into the Kaiterra dashboard to view your air quality data...
Page 4
To clear all settings and put the Sensedge Go back into its factory state: 1. Locate the reset hole on the back of the Sensedge Go, below the power switch. 2. Turn on the device and wait for it to boot up fully, confirmed when the blue LED light turns off.