Specification
(cont.)
Type AWO-M-E-AC 251.A/
AWO-M-E-AC-AF 251.A
Outdoor unit dimensions
Total length
Total width
Total height
Indoor unit dimensions
Total length
Total width
With 1 integrated heating/cooling
■
circuit
With 2 integrated heating/cooling
■
circuits
Total height
Total weight
Indoor unit with 1 integrated heating/
cooling circuit
Empty
■
Filled (max.)
■
Indoor unit with 2 integrated heating/
cooling circuits
Empty
■
Filled (max.)
■
Outdoor unit
Permissible operating pressure
on the secondary side
Connections with connection pipes
supplied
Heating water flow/return, heating/
cooling circuits or external buffer cyl-
inder
Heating water flow/return, DHW cyl-
inder
Outdoor unit heating water flow/
return
Length of connection line indoor
outdoor unit (hydraulic connec-
—
tion set)
Sound power of the outdoor unit at rated
heating output
(Measurements with reference to EN 12102/
EN ISO 9614-2)
Assessed total sound power level at
A7/W55
ErP
■
Max.
■
Low-noise mode
■
04
06
04 2C
06 2C
mm
600
mm
1144
mm
841
mm
360
mm
450
mm
600
mm
920
kg
47
kg
75
kg
54
kg
82
kg
162
bar
3
MPa
0.3
mm
Cu 28 x 1.0 Cu 28 x 1.0 Cu 28 x 1.0 Cu 28 x 1.0
mm
Cu 22 x 1.0 Cu 22 x 1.0 Cu 22 x 1.0 Cu 22 x 1.0
mm
Cu 28 x 1.0 Cu 28 x 1.0 Cu 28 x 1.0 Cu 28 x 1.0
m
5 to 20
dB(A)
49
dB(A)
55
dB(A)
49
08
10
08 2C
10 2C
600
600
1144
1144
841
841
360
360
450
450
600
600
920
920
47
47
75
75
54
54
82
82
162
162
3
3
0.3
0.3
5 to 20
5 to 20
49
49
57
58
49
49
Specification
13
13 2C
600
600
1144
1144
1382
1382
360
360
450
450
600
600
920
920
47
47
75
75
54
54
82
82
215
215
3
3
0.3
0.3
Cu 28 x 1.0
Cu 22 x 1.0
Cu 28 x 1.0
5 to 20
5 to 20
54
54
58
59
54
54
185