Sign In
Upload
Manuals
Brands
Viessmann Manuals
Heat Pump
Vitocal 252-A Series
Viessmann Vitocal 252-A Series Manuals
Manuals and User Guides for Viessmann Vitocal 252-A Series. We have
2
Viessmann Vitocal 252-A Series manuals available for free PDF download: Installation And Service Instructions Manual, Service Instructions Manual
Viessmann Vitocal 252-A Series Service Instructions Manual (200 pages)
One Base
Brand:
Viessmann
| Category:
Heat Pump
| Size: 4 MB
Table of Contents
Safety Instructions
2
Target Group
2
Working on the System
4
Connecting Cables
6
Repair Work
6
Table of Contents
9
Information Symbols
21
Introduction Scope of Functions
22
System Examples
22
Function Description CAN Bus System
23
CAN Bus Subscriber
23
Commissioning the CAN Bus Subscribers in a System Network
24
Defrost
24
Defrost Conditions
25
Defrosting Is Being Prepared
25
Defrost Process
27
End of the Defrost Process
28
Heating/Cooling
29
System Configuration
29
Determining the Flow Temperature with Weather Compensation
30
Control of the Flow Temperature for Indoor Units with 1 Integral Heating/Cooling Circuit
31
Control of the Flow Temperature for Indoor Units with 2 Integral Heating/Cooling Circuits
31
4/3-Way Valve Position for Heating/Cooling Demand
32
Starting and Stopping the Compressor When Heating/Cooling Is Required
36
Changeover Heating/Cooling
37
Auxiliary Functions
38
DHW Heating
39
Systems with DHW Cylinder
39
Flow Rate Control with Hydro Autocontrol
43
4/3-Way Valve
44
Minimum Flow Rates
45
Adjusting Minimum Flow Rates to the System Hydraulics
46
Float Air Vent Valve
47
Design
47
Separation of Refrigerant from the Heating Water
47
Further Components of the Safety Concept
48
Filling and Venting the System
49
Emergency Mode
49
Booster Heaters for Emergency Mode
50
System Configuration Setting Parameters
51
Setting Parameters on the HMI Programming Unit
51
Setting Parameters Via the Viguide App
51
Setting Parameters Via Viguide Web Applications
52
Commissioning Assistant 933 Type of Heating/Cooling Circuit 1
54
Parameter Group 933.0 Properties, Heating/Cooling Circuit 1
54
Type of Heating/Cooling Circuit 2
54
Properties, Heating/Cooling Circuit 2
54
Type of Heating/Cooling Circuit 3
54
Properties, Heating/Cooling Circuit 3
54
Type of Heating/Cooling Circuit 4
54
Properties, Heating/Cooling Circuit 4
54
1415 Operating Mode of Heating/Cooling Circuit 1
54
1416 Operating Mode of Heating/Cooling Circuit 2
55
1417 Operating Mode of Heating/Cooling Circuit 3
55
1418 Operating Mode of Heating/Cooling Circuit 4
55
General Parameter Group
59
Automatic Summer/Wintertime Changeover
60
504.6 Efficient Upper Limit
64
534.0 Circulation Pump Run-On after Cylinder Heating
64
873 DHW Hygiene Function
64
873.0 Activation of Increased DHW Hygiene
64
874 Hygiene Function for Set Cylinder Temperature
65
874.0 Set Cylinder Temperature for Increased DHW Hygiene Function
65
Holding Time, Set Cylinder Temperature for Increased DHW Hygiene Function
65
875 Hygiene Function Start Time
65
875.0 Start Time Increased DHW Hygiene
65
876 Hygiene Function Weekday
65
876.0 Weekday Increased DHW Hygiene
65
1085 Hysteresis for Cylinder Heating
66
1085.0 Start Hysteresis, Set Cylinder Temperature
66
1085.1 Stop Hysteresis, Set Cylinder Temperature
66
1087 Times for DHW Heating
66
1087.0 Max. Duration, DHW Heating
66
1087.1 Min. Delay until Next Time DHW Is Heated
66
1101 Speed Settings of the Secondary Pump for DHW Heating
67
1101.0 Secondary Pump Min. Speed for DHW Heating
67
1101.1 Secondary Pump Max. Speed for DHW Heating
67
1101.2 Secondary Pump Set Speed for DHW Heating
67
2257 Offset for Cylinder Heating
67
2257.0 Flow Temperature Boost During Cylinder Heating with Target Temperature
67
3029 Operating Mode for DHW Heating
67
3066 High DHW Demand Recognised
68
3066.0 Draw-Off Volume Threshold
68
3066.1 Time Threshold
68
3068 Set DHW Temperature for Target Temperature Control
68
3069 DHW Demand Sensor
69
Parameter Group for Heat-Notes
70
Ing/Cooling Circuit 897 Screed Drying
70
897.0 Screed Drying
70
Properties, Heating/Cooling Circuit 1
71
Priority DHW Heating, Heating/Cooling Circuit 1
71
Temperature Differential, Flow Temperature, Heating/Cooling Cir- Cuit 1
71
Room Temperature Influence, Heating, Heating/Cooling Circuit 1
71
Room Temperature Influence, Heating/Cooling Circuit 1
71
Properties, Heating/Cooling Circuit 2
71
Priority DHW Heating, Heating/Cooling Circuit 2
71
Temperature Differential, Flow Temperature, Heating/Cooling Cir- Cuit 2
72
Room Temperature Influence, Heating, Heating/Cooling Circuit 2
72
Room Temperature Influence, Heating/Cooling Circuit 2
72
Properties, Heating/Cooling Circuit 3
72
Priority DHW Heating, Heating/Cooling Circuit 3
72
Temperature Differential, Flow Temperature, Heating/Cooling Cir- Cuit 3
73
Room Temperature Influence, Heating, Heating/Cooling Circuit 3
73
Room Temperature Influence, Heating/Cooling Circuit 3
73
Properties, Heating/Cooling Circuit 4
73
Priority DHW Heating, Heating/Cooling Circuit 4
73
Temperature Differential, Flow Temperature, Heating/Cooling Cir- Cuit 4
73
Room Temperature Influence, Heating, Heating/Cooling Circuit 4
73
Room Temperature Influence, Heating/Cooling Circuit 4
74
1100 Speed Settings for Secondary Pump in Heating Mode
74
1100.0 Min. Speed, Secondary Pump
74
1100.1 Max. Speed, Secondary Pump
74
1100.2 Secondary Pump Set Speed
74
1102 Speed Settings for Heating Circuit Pump, Heating/Cooling Circuit 1
74
1102.0 Heating Circuit Pump Min. Speed, Heating/Cooling Circuit 1
74
1102.1 Heating Circuit Pump Max. Speed, Heating/Cooling Circuit 1
75
1102.2 Heating Circuit Pump Set Speed, Heating/Cooling Circuit 1
75
1103 Speed Settings for Heating Circuit Pump, Heating/Cooling Circuit 2
75
1103.0 Heating Circuit Pump Min. Speed, Heating/Cooling Circuit 2
75
1103.1 Heating Circuit Pump Max. Speed, Heating/Cooling Circuit 2
75
1103.2 Heating Circuit Pump Set Speed, Heating/Cooling Circuit 2
75
1192 Set Flow Temperature Limits, Heating/Cooling Circuit 1
75
1192.0 Min. Flow Temperature, Heating, Heating/Cooling Circuit 1
75
1192.1 Max. Flow Temperature, Heating, Heating/Cooling Circuit 1
75
1193 Set Flow Temperature Limits, Heating/Cooling Circuit 2
76
1193.0 Min. Flow Temperature, Heating, Heating/Cooling Circuit 2
76
1193.1 Max. Flow Temperature, Heating, Heating/Cooling Circuit 2
76
1194 Set Flow Temperature Limits, Heating/Cooling Circuit 3
76
1194.0 Min. Flow Temperature, Heating, Heating/Cooling Circuit 3
76
1194.1 Max. Flow Temperature, Heating, Heating/Cooling Circuit 3
77
1195 Set Flow Temperature Limits, Heating/Cooling Circuit 4
77
1195.0 Min. Flow Temperature, Heating, Heating/Cooling Circuit 4
77
1195.1 Max. Flow Temperature, Heating, Heating/Cooling Circuit 4
77
1232 Configuration of General Digital Input 1
77
1232.0 Function of Digital Input 1
77
1395 Heating Limit: Economy Function, Outside Temperature, Heating/ Cooling Circuit 1
78
1395.0 Enable Summer Economy Control, Heating/Cooling Circuit 1
78
1395.1 Summer Saving Temperature Threshold, Heating/Cooling Cir- Cuit 1
78
1396 Heating Limit: Economy Function, Outside Temperature, Heating/ Cooling Circuit 2
78
1396.0 Enable Summer Economy Control, Heating/Cooling Circuit 2
78
1396.1 Summer Saving Temperature Threshold, Heating/Cooling Cir- Cuit 2
79
1397 Heating Limit: Economy Function, Outside Temperature, Heating/ Cooling Circuit 3
79
1397.0 Enable Summer Economy Control, Heating/Cooling Circuit 3
79
1397.1 Summer Saving Temperature Threshold, Heating/Cooling Cir- Cuit 3
79
1398 Heating Limit: Economy Function, Outside Temperature, Heating/ Cooling Circuit 4
79
1398.0 Enable Summer Economy Control, Heating/Cooling Circuit 4
79
1398.1 Summer Saving Temperature Threshold, Heating/Cooling Cir- Cuit 4
80
1627 External Set Temperature for Heating/Cooling Circuit 1
80
1627.0 External Circuit Fixed Target Temperature, Heating/Cooling Cir- Cuit 1
80
1628 External Set Temperature for Heating/Cooling Circuit 2
80
1628.0 External Circuit Fixed Target Temperature, Heating/Cooling Cir- Cuit 2
80
1629 External Set Temperature for Heating/Cooling Circuit 3
80
1629.0 External Circuit Fixed Target Temperature, Heating/Cooling Cir- Cuit 3
80
1630 External Set Temperature for Heating/Cooling Circuit 4
81
Service Messages
185
Status Messages
185
Information Messages
188
CAN Bus Cable
192
Pressure Sensors
197
Advertisement
Viessmann Vitocal 252-A Series Installation And Service Instructions Manual (212 pages)
Air source heat pump, monoblock version for heating and cooling operation
Brand:
Viessmann
| Category:
Heat Pump
| Size: 33 MB
Table of Contents
Safety Instructions
2
Target Group
2
Working on the System
4
Connecting Cables
6
Repair Work
6
Disposal of Packaging
13
Intended Use
13
Requirements for On-Site Connections
19
Preparing for Installation
19
Transport by Crane
26
Installation Information
26
Wall Mounting
27
Roof Installation
27
Installation Location
29
Safety Zone
30
Minimum Clearances
32
Condensate Drain
32
Floorstanding Installation
33
Installing the Indoor Unit
43
Requirements for the Installation Room
46
Hydraulic Connections
51
Opening the Outdoor Unit
51
Temperature Limiter
57
Contact Humidistat
58
Preparing the Electrical Connections
61
Electrical Connection of the Indoor Unit
63
Connecting the Energy Meter
78
Electrical Connection of the Outdoor Unit
81
Recommended Cable
83
Power Supply
87
Commissioning the System
97
Commissioning, Inspection, Maintenance
97
Commissioning Requirements
97
Commissioning Assistant
99
Filling the System
106
Venting the System
111
Opening the Indoor Unit
112
Testing the Anode Connection
113
Replacing the Protective Magnesium Anode
114
Draining the Appliance on the DHW Side
114
Cleaning the Outdoor Unit Heat Exchanger (Evaporator)
120
Cleaning the DHW Cylinder
122
Checking the Indoor Unit Electrical Connections for Firm Seating
124
Checking the Outdoor Unit Electrical Connections for Firm Seating
124
Resetting the High Limit Safety Cut-Out
125
Closing the Heat Pump
125
Checking the Heat Pump for Noise
126
Adjusting the Heating Curve
126
Instructing the System User
127
Service Menu
129
System Configuration and Diagnostics
129
Refrigerant Circuit
130
Troubleshooting
135
Troubleshooting Measures
136
Overview of Internal Components
141
Checking the Temperature Sensors
151
Checking the Fuse
153
Removing the Outer Casing
157
Outdoor Unit Maintenance
157
Overview of Electrical Components
163
Overview of Internal Components
171
Filling the Refrigerant Circuit
178
Checking the Temperature Sensors
182
Checking the Fuses
184
Specification
187
Commissioning Order
201
Final Decommissioning and Disposal
201
Ordering Individual Parts
203
Advertisement
Related Products
Viessmann AWOT-E-AC 251.A 10
Viessmann AWOT-E-AC 251.A 13
Viessmann AWOT-E-AC 251.A 16
Viessmann AWOT-E-AC 251.A 19
Viessmann AWOT-M-E-AC 251.A 04
Viessmann AWOT-M-E-AC 251.A 06
Viessmann AWOT-M-E-AC 251.A 08
Viessmann VITOCAL 250-A
Viessmann AWO-E-AC 251.A
Viessmann AWO-M-E-AC 251.A SP
Viessmann Categories
Boiler
Toy
Control Unit
Heat Pump
Solar panel
More Viessmann Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL