  • Page 1 ASSEMBLY AND OPERATION MANUAL WMD-06 Motorized electromechanical swing gate...
  • Page 2 WMD-06 Motorized electromechanical swing gate CONTENTS 1 APPLICATION..........................2 2 OPERATING CONDITIONS ....................... 2 3 TECHNICAL SPECIFICATIONS ....................2 4 DELIVERY SET .......................... 3 4.1 Standard delivery set ...................... 3 4.2 Additional equipment (to be supplied upon request) ............4 5 DESCRIPTION ...........................
  • Page 3 • WRC – wireless remote control. APPLICATION The WMD-06 Motorized electromechanical swing gate (hereinafter, the swing gate) is designed for managing pedestrian flows at checkpoints of banks, administrative buildings, retail outlets, railway terminals, airports, etc. Being an up-market model, it is recommended for use at facilities with the highest requirements for design and comfort.
  • Page 4 WMD-06 Motorized electromechanical swing gate Figure 1. Overall dimensions of the swing gate DELIVERY SET Standard delivery set Basic equipment: Gate post: fixed base ..........................1 housing ..........................1 top cover ..........................1 Glass swing panel ........................1 Note: The swing panel is a separate item in the price list and is to be purchased separately. The swing panel type is selected by the customer when ordering the gate.
  • Page 5 Assembly and Operation Manual Additional equipment (to be supplied upon request) WRC kit ............................. 1 SG1 Yellow Circle safety sticker ....................1 SG2 Matt Ring safety sticker ..................... 1 DESCRIPTION Main features • The swing gate can operate both as a stand-alone unit, via its RC panel or WRC, and as a part of the ACS.
  • Page 6 WMD-06 Motorized electromechanical swing gate Figure 2. Overall view of the swing gate 1 – fixed base; 2 – housing; 3 – top cover; 4 – glass swing panel; 5 – metal ring; 6 – control board; 7 – rotary support; 8 – M3 screw (3 pcs); 9 – anchor; 10 – M10 nut;...
  • Page 7 Assembly and Operation Manual Figure 3. Overall view of the control board XT1, XT2 – terminal blocks; 1 – power cable +24 V; 2 – control cable (from RC panel / WRC unit / ACS controller); 3 – jumper wire (installed by default); 4 –...
  • Page 8 WMD-06 Motorized electromechanical swing gate Terminal Item Designation block Fire Alarm Emergency unlocking device input Power supply’s negative terminal Unlock A Inputs for gate control Stop ХТ2 Unlock B Led A Indication outputs of RC panel Stop Led B Sound signal output of RC panel...
  • Page 9 Assembly and Operation Manual Figure 5. Standard orientation of the RC panel relative to the swing panel’s opening direction Table 2. Connection of wires of the RC panel cable to the XT2 terminal block in standard and reversed orientation of the RC panel Orientation Number Name...
  • Page 10 WMD-06 Motorized electromechanical swing gate In case of combined connection, signals sent by control devices may overlap. In this case, the reaction of the gate will correspond to the reaction towards the generated combination of input signals. Control devices are connected to the Unlock A, Stop, and Unlock B control inputs. The gate is operated by sending a low-level signal to the Unlock A, Stop, Unlock B contacts of the XT2 terminal block in relation to the GND contact.
  • Page 11 Assembly and Operation Manual The control element shall meet the following signal requirements: control element – relay contact: minimum commutation current ................max. 4 mA closed contact resistance (including connection cable resistance) ............max. 200 Ohm control element – open collector output circuit: voltage at the closed contact (low-level signal, at the control board input) ............
  • Page 12 WMD-06 Motorized electromechanical swing gate Output stages for Light A (Light B) are relay changeover contacts with the following signal specifications: maximum commutation DC voltage ................... 30 V maximum commutation AC voltage ................... 42 V maximum commutation AC / DC current ................3 A closed contact resistance ..................
  • Page 13 Assembly and Operation Manual Operation safety Observe general safety requirements for the use of electrical equipment when operating the swing gate. Warning! Do not use the swing gate in environment different from that specified in Section 2. • Do not use the swing gate if the power supply voltage differs from that specified in •...
  • Page 14 WMD-06 Motorized electromechanical swing gate The item numbers in the installation procedure are given according to Fig. 2 unless stated otherwise. The electrical connection layout is given in Fig. 11. Terminal blocks and jumpers’ positioning on the control board is shown in Fig. 3. Cables used for installation and their maximum lengths are specified in Section 8.3.
  • Page 15 Assembly and Operation Manual 13. Mount the glass swing panel according to Fig. 12. To do this, fix the panel (6) on the rotary support (7) using elements (1) – (5). Attention! Be careful while mounting the glass panel, prevent it from falling and being hit by metal elements of the post.
  • Page 16 WMD-06 Motorized electromechanical swing gate Table 3. List of elements on the electrical connection layout Item Designation Number, pcs А1 Control board Power supply unit of the swing gate (+24V DC; 4А) А2 ∗ Power supply unit of remote indicators А3...
  • Page 17 Assembly and Operation Manual OPERATION Observe safety requirements given in Section 7.2 when operating the swing gate. Warning! • Do not move any objects with dimensions exceeding the passageway width through the swing gate’s passage zone. • Do not jerk or hit elements of the swing gate so as to prevent their mechanical damage. Do not dismantle or adjust mechanisms ensuring operation of the swing gate.
  • Page 18 WMD-06 Motorized electromechanical swing gate Note: When operating as part of the PERCo-S-20 system, the swing panel stays open in the Single passage in chosen direction mode for the time determined by the Unlocked state holding time parameter. The Single passage in chosen direction mode can be changed to the Free passage mode in the same direction or to the Passage denial mode;...
  • Page 19 Assembly and Operation Manual Troubleshooting Possible faults to be corrected by the user themselves are listed in Table 6. In an unlikely event of other faults, please consult the PERCo Technical Support Department. Table 6. Troubleshooting Fault Possible cause Remedy When the gate is De-energize the power supply unit.
  • Page 20 WMD-06 Motorized electromechanical swing gate APPENDIX 1. Algorithm for transmission of control signals in pulse control mode The command is an active signal front (signal transfer from the high level to the low level) at any of the contacts at presence of the corresponding signal levels at the other contacts.
  • Page 21 PERCo Polytechnicheskaya str., 4, block 2 194021, Saint Petersburg Russia Tel: +7 812 247 04 64 E-mail: export@perco.com support@perco.com www.perco.com...