Being an up-market model, it is recommended to meet the highest requirements for design and comfort. It can be installed together with other turnstiles and railings produced by PERCo or it can be used as a separate device.
Assembly and Operation Manual Figure 1. Overall dimensions DELIVERY SET Standard delivery set Basic equipment: Gate post: fixed base ..........................1 housing ........................... 1 cover ............................1 Glass panel ..........................1 Note: Type of panel, AGG-650 (700 mm passageway width) or AGG-900 (900 mm passageway width) is chosen by the customer.
WMD-06 Motorized electromechanical swing gate Optional equipment (upon request) In addition to the standard delivery set the following equipment can be supplied on request: Power supply unit .........................1 WRC kit ............................1 DESCRIPTION Main features The swing gate can operate both as a standalone unit and as a part of the ACS. Two control modes are available: pulse control mode and potential control mode.
Assembly and Operation Manual Terminal Item Designation block Fire Alarm Input for emergency unlocking device Power supply negative terminal Unlock A Inputs for gate control Stop ХТ2 Unlock B Led A Indication outputs of RC panel Stop Led B Sound signal output of RC panel Sound RC-panel The RC-panel (17) is a small desktop device made of shockproof ABS plastic that serves for...
WMD-06 Motorized electromechanical swing gate Figure 5. Standard orientation of RC panel relative to gate opening direction Table 2. Connection of RC panel cable to XT2 connector block in standard and reversed orientation of the RC panel Orientation Number Title...
Page 11
Assembly and Operation Manual Control devices are connected to Unlock A, Stop and Unlock B control inputs. The gate is operated by applying a low-level signal to Unlock A, Stop, Unlock B contacts with GND contact of XT2 terminal block. Algorithms of control signals sending are given in Appendices A and B. A normally open relay contact or open collector output circuit can be used as a control element (see Figure 6 and Figure 7).
Page 12
WMD-06 Motorized electromechanical swing gate control element – open collector output circuit: voltage at the closed contact (low-level signal, at the control board input) ............max. 0.8 V 5.4.2 PASS outputs PASS A (Pass A and Common contacts of XT1 terminal block), PASS B (Pass В and Common contacts of XT1 terminal block) outputs are basically a relay.
Assembly and Operation Manual Abnormal situations during gate operation In a case of any impediment to the free rotation of the swing gate an automatic switching to overload mode is provided. The mode is used to avoid damage to electromechanical elements due to overheating.
WMD-06 Motorized electromechanical swing gate ASSEMBLY AND INSTALLATION Observe safety requirements given in the Section 7.1 during installation. General recommendations Proper installation is crucial to performance and serviceability of the swing gate. We advise you to study this Manual before installation work and follow the instructions to the latter.
Page 15
Assembly and Operation Manual 3. Install power supply unit in accordance with its operation manual. Figure 10. Mounting hole layout 4. If it is necessary to lay power cables (13) and control cables (14) under the floor, prepare an electrical conduit in the floor in the zone where cables are inserted into the gate post. The zone positioning is given in Fig.
Page 16
WMD-06 Motorized electromechanical swing gate Figure 11. Wiring diagram Table 3. List of elements on the wiring diagram Item Designation Comment А1 Control board Power supply unit of the swing gate +24V DC; 4А А2 Power supply unit of remote indicators А3...
WMD-06 Motorized electromechanical swing gate Pulse control mode Pulse control mode is used to operate the swing gate with RC panel, WRC devices and ACS controllers that support this mode. Operating modes setting is performed by applying a low-level signal or by closing Unlock A, Stop, Unlock B contacts with GND contact of XT2 terminal block.
24 hours under normal climate conditions corresponding to operation conditions. MAINTENANCE Technical maintenance of the swing gate should be performed only at PERCo service center. We recommend using liquid non-abrasive cleansers containing ammonia to clean a swing gate post and a glass panel when dirty.
WMD-06 Motorized electromechanical swing gate APPENDIX A. Control signal algorithm in pulse control mode The command is a signal active front (signal transfer from the high level to the low level) at any of the contacts at presence of the corresponding signal levels at the other contacts.
Need help?
Do you have a question about the WMD-06 and is the answer not in the manual?
Questions and answers