Positive displacement flowmeter

Advertisement

Quick Links

Positive displacement
flowmeter
Models 814 and 817
April 2014
Date of issue
Form number
404346B
Section
F22
Page
44B
D A N G E R
Read manual prior to installation or use
of this product. Keep manual nearby for
future reference. Failure to follow
instructions and safety precautions can
result in death or serious injury.
Installation and maintenance guide

Advertisement

loading
Need help?

Need help?

Do you have a question about the Lincoln 814 and is the answer not in the manual?

Questions and answers

Summary of Contents for SKF Lincoln 814

  • Page 1 Installation and maintenance guide Positive displacement flowmeter Models 814 and 817 April 2014 Date of issue D A N G E R Form number 404346B Read manual prior to installation or use Section of this product. Keep manual nearby for Page future reference.
  • Page 2 Contents Safety ......Explanation of signal words for safety ..... . . Introduction .
  • Page 3 Safety Explanation of signal Please read this information carefully before words for safety installing the flow meter. Read and carefully observe these installation Read and retain this instruction manual to instructions before installing/operating/ assist you in the operation and maintenance troubleshooting the assembly.
  • Page 4 Introduction General information Please read and retain this instruction Model 814 product specifications manual to assist you in the operation and maintenance of this quality product. Accuracy ± 0.5% of reading Type Oval gear This manual assists you in operating Flow rate 0.26 to 8 U.S.
  • Page 5 Operating principle Calibration Once in the programming menu the operator will be able to access (and adjust) The calibration mode enables, in case the Operational overview three programming selections. operator suspects the accuracy of the meter is in question, the operator to dispense a 1 Setting decimal place known volume of fluid through the meter When fluid passes through the meter the...
  • Page 6 Assembly Changing the battery Returning to operation mode At any stage the unit can be returned to the operation mode by pressing the red reset A low battery warning will be displayed on button for approximately three seconds. the LCD screen when there is 5% power left. The warning will remain active until the battery is replaced.
  • Page 7 Meter dimensions Fig. 1 Model 814 in. (59 mm) in. (98 mm) in. (88 mm) Fig. 2 Model 817 in. (67 mm) in. (98 mm) in. (88 mm)
  • Page 8 Illustrated parts breakdown Parts list Item Part description Wetted parts Protective boot – Electronic module retaining screws – Electronic module – O-ring – Meter body CA313 aluminum Rotor set Acetal (delrin) O-ring Nitrile butadiene rubber Meter cap CA313 aluminum Meter cap screws –...
  • Page 9 Troubleshooting Problem Cause Remedy Fluid will not flow through meter Foriegn matter blocking rotors • Dismantle meter, clean rotors Damaged rotors • Replacement rotor assembly required Meter connections over tightened • Readjust connections Fluid is too viscous • Refer to specifications for maximum viscosity (page 4) Reduced flow through meter Partially blocked •...
  • Page 10 Lincoln industrial Special limited 5 year warranty- This warranty gives you specific legal limited oil meters, limited fluid control standard warranty rights. You may also have other rights that valves, aod (air-operated diaphragm) vary by jurisdiction. pumps. Customers not located in the Western Standard limited warranty Hemisphere or East Asia: Please contact Lincoln warrants the 712 series control...
  • Page 11 This page intentionally left blank.
  • Page 12 Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. SKF PUB LS/I1 14611 EN.R1 · April 2014 · Form 404346B lincolnindustrial.com...