Page 1
USS-335 Installation Reverse Osmosis Instructions Filtration System Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 NSF/ANSI Standards Step 7 System Tested and Certified by NSF International against NSF/ANSI Standard 42 for Aesthetic Chlorine, Taste & Odor, and Particulate Class III.
Page 2
Tools & Materials Required main components secondary tools needed for components installation filter system head phillips adjustable screwdriver wrench mounting screws kitchen faucet adapter 1/8” drill bit utility knife white tubing red tubing (3/8" and 1/4") (3/8" and 1/4") drill tape measure Redi-Twist filters (1st, 2nd, and 3rd stage)
Page 3
Step 8 Install Redi-Twist™ Filter and Check for Leaks 1/4 turn 866.709.2086 Internet & Mobile Free Installation Video My Brita Redi-Twist™ Filter System ® System Cartridge Model No(s). Date Purchased / Date to Replace For FREE Filter Replacement Reminder, go to www.protectplus.com...
Page 4
Before You Begin Please read all instructions, specifications, and precautions before installing and using your water filter system. NOTICE Precautions: for cold water use only. Consult your local plumbing codes and install accordingly. This filter must be protected from freezing, which can cause cracking of the filter and water leakage. Because of the product’s limited service life and to prevent costly repairs or possible water damage, we strongly recommend that the head of the filter be replaced every five years.
Page 5
Plan Your Installation NOTE: DO NOT CONNECT 3/8" RED DRAIN TUBING TO DRAIN WITH A GARBAGE DISPOSAL. 1/4” line to Faucet 3/8" white tubing to faucet Kitchen 3/8" red tubing Packaged Items 3/8” line to Drain Faucet to drain Adapter Shown in White 3/8"...
Page 6
Introduction Thank you for your recent purchase of the Brita® Reverse Osmosis (RO) Filtration System. You have purchased a filtration system with a technology that has proven itself effective for filtering ultra-fine water contaminants. This method of filtration is the most common water treatment technology used by premium bottled water companies.
Page 7
connect to auxiliary faucet Step 1 Install Kitchen Faucet Adapter materials and tools needed Note: If rigid plumbing pipe (metal or plastic) is used, you may need to shorten supply pipe using a hacksaw or pipe cutter to accomodate the Kitchen Faucet Adapter.
Page 8
connect to auxiliary faucet Install RO Drain Step 2 Connector materials and tools needed CAUTION WARNING safety glasses drill DRAIN CONNECTOR INSTALLATION FOAM SEAL Note: Extra care should be taken when entering drains near dishwashers or food waste disposals, as backflow may occur through the air gap and cause flooding.
Page 9
connect to auxiliary faucet Step 3 Install RO Filter System Assembly materials and tools needed WARNING phillips safety glasses drill screwdriver Mount to cabinet in vertical position 4-6" FROM BOTTOM Mount the Reverse Osmosis Filter System Assembly Head using the two mounting screws. The mounting screws allow you to lift the RO Filter System Assembly without any hardware removal.
Page 10
connect to auxiliary faucet Install Water Storage Step 4 Tank materials and tools needed Note: The Tank Ball Valve fitting on the Water 000.00 Storage Tank may need to be tightened 3-4 turns to get a good seal. DO NOT OVERTIGHTEN. digital air pressure gauge •...
Page 11
connect to auxiliary faucet Step 5 Install RO Faucet materials and tools needed WARNING safety glasses drill Select Location of Reverse Osmosis Faucet Mounting Hole. You will need to select the location of the Reverse 1/4” line to Faucet 3/8" white tubing to faucet Osmosis Faucet.
Page 12
connect to auxiliary faucet Install RO Faucet Step 5 << Step continued from previous page materials and tools needed • Locate and organize your RO Faucet install parts. See list on page 2. WARNING • Attach 3/8" white tube to RO Faucet Body. mounting surface •...
Page 13
connect to auxiliary faucet Step 6 Connect Water Lines materials and tools needed Install 1/4" Plastic Tubing for Water Supply Line from Kitchen Faucet Adapter to System Head Inlet • Determine lengths of 1/4" plastic safety glasses tubing needed to connect to both inlet port to Auxiliary Faucet Adapter and CAUTION outlet port to Auxiliary Faucet.
Page 14
connect to auxiliary faucet Step 6 Connect Water Lines << Step continued from previous page *Note: System will NOT operate without Restrictor. Note: Tubing lengths should allow for the removal of the assembly from the mouting screws for servicing. If tubing lengths are shortened for neater appearance, it may be necessary to keep the assembly on the mounting screws for service.
Page 15
connect to auxiliary faucet Step 6 Connect Water Lines << Step continued from previous page materials and tools needed CAUTION WARNING utility knife 1/4” line to Faucet 3/8" white tubing to faucet Kitchen 3/8" red tubing Packaged Items 3/8” line to Drain Faucet to drain Adapter...
Page 16
connect to auxiliary faucet Step 7 Sanitize, Test and Purge System materials and tools needed Note: The bleach must be completely removed WARNING from system before drinking RO water. See purging instructions below. Sanitize the System Sanitizing is recommended immediately after installation of the RO Filter System Assembly.
Page 17
connect to auxiliary faucet Sanitize, Test and Step 7 Purge System << Step continued from previous page Pressure Test the System (IMPORTANT: Complete sanitizing procedures on Page 16 before pressure testing.) • Open cold water supply valve to RO Filter System Assembly. •...
Page 18
connect to auxiliary faucet Install Redi-Twist Filters ™ Step 8 and Test for Leaks • Remove the 1st Stage filter cartridge first from the system to relieve pressure on the RO filter. • Remove the 3rd Stage filter cartridge. • Discard all of the Redi-Twist™...
Page 19
connect to auxiliary faucet connect to auxiliary faucet Filter Replacement Filter Replacement (every 6 months) (every 12 months) 1st Stage and 3 Stage Filter Replacement: Membrane Filter Replacement: 1/4 turn 1/4 turn For FREE Filter Replacement Reminder, go to www.protectplus.com Note: Place paper towels or rag under the filter system to catch any water drips.
Page 20
Install System/Drain in Remote Location materials and tools needed WARNING Install a Remote Drain Point and Air Gap (Remote Location) You can also run the drain tubing to an existing drain in the house. A floor drain, laundry tub, standpipe, sump, etc. are suitable drain points. This type of drain is preferred over the drain connector.
Need help?