Brita C150 FINEST Installation Instructions
Brita C150 FINEST Installation Instructions

Brita C150 FINEST Installation Instructions

Advertisement

BRITA C150 FINEST
Please read carefully and retain for future reference.
CONTENTS
1.

Important Information

2.
3.
4.
Installation Instructions
5.
6.
7.
1. Important Informa�on
-
For correct operation of this appliance, it is essential to strictly observe these installation and operating instructions.
-
Do not use this product with water that is microbiologically unsafe or water of unknown quality without adequate disinfection before or
af t er this system.
-
Installation must comply with any existing State or Local Plumbing codes. Some Plumbing Codes require the installation of water filter
systems to be carried out by a licensed plumber.
-
For COLD water use only. Maximum temperature 38°C. Minimum temperature 2°C.
-
For internal use only.
-
The inlet water pressure to this water filter housing must not exceed 900kPa (130psi).
-
A certified pressure limiting valve not exceeding 650kPa (95psi), dual check backflow prevention valve must be installed on the inlet line
immediately preceding this water filter housing. This valve is included with this system (see Item 10 in Parts Section).
-
We also recommend the installation of a water hammer protection device to protect the water filter housing and its installation. Where
water hammer problems exist, a water hammer protection device must be installed. Symptoms of water hammer can be noisy, shuttering
and banging pipes when water consuming appliances are operating or taps are turned off. Should the system not be used for 2 days or more,
flush 1-2 litres of water through the system before consuming the water.
-
To ensure the high level of performance and protection provided from this water filter system, only use Bombora replacement cartridges
which have a maximum cartridge life of 12 months.
-
Af t er installation, check the output water with a test strip and then test every 6-8 weeks af t erwards to establish your filter life based on your
average use. The TH reading should be below low range (less than 80PPM). If you get a higher reading than this on installation, call us to
discuss adjusting your bypass setting or restricting water flow further. Suggested filter cartridge change is 12 months or when the sof t ening
capacity is diminished (over 80 PPM TH), whichever comes sooner.
bomborasupplies.com.au
1300 724 249
PART # C150KIT-FINEST
sales@bomborasupplies.com.au

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C150 FINEST and is the answer not in the manual?

Questions and answers

Summary of Contents for Brita C150 FINEST

  • Page 1 BRITA C150 FINEST PART # C150KIT-FINEST INSTALLATION INSTRUCTIONS Please read carefully and retain for future reference. CONTENTS Important Information Included Parts Filter Head Assembly Instructions Installation Instructions 4.1. Auxiliary Tap Connection Plumbing in Your System Replacing the Filter Cartridge Warranty Information 1.
  • Page 2 BRITA C150 FINEST PART # C150KIT-FINEST INSTALLATION INSTRUCTIONS 2. INCLUDED PARTS Filter Cartridge Filter Head Outlet Filter Head Assembly i. 3/8” Female Fitting to 3/8” Quick Connect Fitting ii. 3/8” Stem Fitting to 1/4” Quick-Connect Fitting iii. 3/8” Female Fitting to 3/8” Quick Connect Fitting iv.
  • Page 3 BRITA C150 FINEST PART # C150KIT-FINEST INSTALLATION INSTRUCTIONS 4. Installa�on Instruc�ons NOTE: We recommend moun�ng the water filter system as far away as possible from the dishwasher and hot water pipes to reduce heat exposure to the system. NOTE: The plumbing installa�on kit supplied with this water filter system provides plumbing fittings that will allow easy installa�on on an auxiliary under-sink tap.
  • Page 4 BRITA C150 FINEST PART # C150KIT-FINEST INSTALLATION INSTRUCTIONS 5. Plumbing in Your System Drill a 12mm (1/2”) hole in the desired location in the sink bench top. We suggest placing masking tape over drill spot to prevent drill movement. Drill a 3mm pilot hole first, followed by a 12mm (1/2”) hole for faucet shaf t . Good quality, sharp drill bits and coolant are recommended.
  • Page 5 BRITA C150 FINEST PART # C150KIT-FINEST INSTALLATION INSTRUCTIONS 6. Replacing the Filter Cartridge NOTE: The C150 filter has a shut-off valve at the filter head. The replace the filter cartridge: Rotate the locking handle to divert the water and release the cartridge. Press the flush valve located on the top of the head to depressurise the filter.

Table of Contents