The Dell OpenManage HIP server-management application program generates
alert messages that appear in the Simple Network Management Protocol
(SNMP) trap log file. To see the trap log, select any enterprise under the SNMP
trap log icon.
Alert log messages consist of information, status, warning, and failure mes-
sages for drive, temperature, fan, and power conditions. They can assist you
with identifying a problem and may provide you with information to help you
resolve the problem.
Table 3-3 lists some of the alert log messages from the Dell OpenManage HIP
application program.
The server stopped
functioning and
called the notification
number specified in
the DC Console
Actions tab.
The chassis of an
attached system has
been opened.
The system power
consumption is
exceeding power
supply capacity. The
power supply name
is provided.
The server will
reboot if the Reset
or Power Cycle
option was selected
in the Action on
Hung Server Notifi-
cation section of
the System Console
System tab. If nei-
ther option was
selected, the sys-
tem can be reset
using the Remote
Management fea-
ture in the Dell
Remote Assistant
Card utility.
Check to make sure
the system chassis
is closed.
Verify that all of the
expansion cards in
the system are func-
tioning properly.
Verify that the load
requirements of the
hardware config-
ured in the system
do not exceed the
capacity of the
power supplies.
Codes and Messages
3-13