Dell POWEREDGE 4300 Service Manual page 52

Dell computer motherboard user manual
Hide thumbs Also See for POWEREDGE 4300:
Table of Contents

Advertisement

3-12
Dell PowerEdge 4300 Systems Service Manual
Incorrect Time or
Date settings or
defective system
battery
Defective system
board
Faulty or improperly
seated DIMM or
defective system
board
Microprocessor not
supported by
Q
system
Microprocessor not
supported by BIOS
Wrong microproces-
sor speed; no
microprocessor or
terminator card
installed in one or
more of the
microprocessor
connectors
Some portion of
system firmware is
out of date, possibly
as result of power
being removed from
the system while
servicing the bat-
tery, PSPB, system
board, or SCSI
backplane
Faulty diskette or
hard-disk drive
Check the Time and
Date settings. If the
problem persists,
replace the battery.
Replace the system
board.
Remove and reseat the
DIMMs. If the problem
persists, replace the
DIMMs. If the problem
still persists, replace the
system board.
Install a correct version
of the microprocessor in
the specified micro-
processor connector.
Upgrade the BIOS.
Ensure that each micro-
processor connector has
either a terminator card
or a microprocessor
installed. Ensure only
100-MHz microproces-
sors are used.
Reflash the system firm-
ware from the Dell
Server Assistant CD (if
available) or from the
Dell Web site.
Replace the diskette or
hard-disk drive.

Advertisement

Table of Contents
loading

Table of Contents