Instructions for use
X-plore 8300

Advertisement

loading
Need help?

Need help?

Do you have a question about the X-plore 8300 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dräger X-plore 8300

  • Page 1 Instructions for use X-plore 8300...
  • Page 4 Safety-related information Safety-related information X-plore 8300 – Before using this product, carefully read these instructions for use and those of the associated products. – Strictly follow the instructions for use. The user must fully understand and strictly observe the instructions. Use the product only for the purposes specified in the intended use section of this document.
  • Page 5 If not avoided, it could result in physical injury. It may also be used to alert against unsafe practices. NOTICE Indicates a potentially hazard- ous situation. If not avoided, it could result in damage to the product or environment. X-plore 8300...
  • Page 6 9300998 (Notes on Approval). A complete powered air-purifying system includes the following components (see Figure A and documents 9300998, chapter Components to complete the device): 1 Breathing hose 2 Facepiece 3 Carrying system 4 Blower unit with filter X-plore 8300...
  • Page 7 Half masks and full facepieces can be used with this blower unit, as well as hoods, helmets and protective visors. – X-plore 8300 PAPR unit (masks 160 l/min) Only half masks and full facepieces can be used with this blower unit.
  • Page 8 The filter has medium saturation Filter is almost saturated. Battery capacity of the rechargeable battery 100 % to 76 % Battery capacity of the rechargeable battery 75 % to 51 % Battery capacity of the rechargeable battery 50 % to 26 % X-plore 8300...
  • Page 9 LED 1, 2 and 3 light up Rechargeable battery LED 4 flashes charged up to 99 % All LEDs light up Rechargeable battery is fully charged In case of an error, the symbol flashes red. For further information see: "Troubleshooting", page 23. X-plore 8300...
  • Page 10 2x/mi recur- nute ring Fre- low - low - high - high quency mediu mediu high high General acoustic feedback device switche d on device switche d off High flow rate is set flow rate is set X-plore 8300...
  • Page 11 Filter or recharg eable battery Alarms Missing breath- ing hose when switch- ing the device Filter, recharg eable battery, blower, other faults For further information on acoustic signals in case of warnings and alarms, see chapter 5 Troubleshooting. X-plore 8300...
  • Page 12 The connection types are suitable for the following facepieces: Connector type Facepieces plug-in connector hoods, helmet/hood combina- tions, bump cap/hood combi- nation, helmets with visors round-thread connector half masks, full face masks X-plore 8300...
  • Page 13 The rechargeable battery in the powered air-purifying respirator can be charged using the following chargers: – X-plore 8300 standard charger – X-plore 8300 multi-charger for 5 devices The level of charge is displayed on the control panel of the powered air-purifying respirator.
  • Page 14 – for protecting the user from harmful vapours and gases, – for use in unventilated containers, pits, canals etc., – when there is suspicion of contaminant concentrations that represent an immediate danger to life or health (i.e. IDLH concentrations), – for use in explosion-hazard areas. X-plore 8300...
  • Page 15 For information on approvals, see document 9300998 (Notes on Approval). Declaration of conformity: see www.draeger.com/product- certificates 3.7 Explanation of symbols Sym- Explanation Caution! Follow the instructions for use. Maximum humidity during storage <90% Temperature range of storage conditions +55°C -10°C Expiry date X-plore 8300...
  • Page 16 – at least 17 Vol% oxygen in all European countries except for the Netherlands, Belgium and the UK – At least 19 Vol% oxygen in the Netherlands, Belgium, the UK, Australia and New Zealand Observe the national guidelines in other countries. X-plore 8300...
  • Page 17 "Meaning of the control panel indicators during use", page 8). If no breathing hose is connected, the symbol of the flow rate indicator flashes red slowly and an acoustic signal sounds. A breathing hose and a facepiece must be connected for use. X-plore 8300...
  • Page 18 ► Make sure you hear a clicking sound when the filter is inserted and the breathing hose is plugged in. WARNING Danger for body and life when operated without a filter! If the filter is missing, no warning is displayed. ► Only operate the device with a filter. X-plore 8300...
  • Page 19 (see Figure E). The sealing must neither be missing, contaminated or damaged nor be inserted incorrectly. If necessary, replace the sealing (see "Replacing the sealing on the blower unit", page 34). X-plore 8300...
  • Page 20 When using a back pack: Put the back pack on and fasten the buckles. 10. Don the facepiece (see Instructions for Use of the corresponding facepiece). 11. If necessary, set the higher flow rate (see "Changing the flow rate", page 18). X-plore 8300...
  • Page 21 ► When used with a tight-fitting facepiece (half mask/full face mask), the power-off mode is considered to be an abnormal situation. X-plore 8300...
  • Page 22 2. Remove the facepiece (see Instructions for Use of the corresponding facepiece). 3. Turn off the blower unit (see "Turning the device off", page 18). 4. Open the carrying system and put down the device. 5. Clean and disinfect the device (see "Cleaning and disinfecting", page 26). X-plore 8300...
  • Page 23 1) Estimated period of use determined under laboratory conditions (with fully charged rechargeable battery and 20 °C ambient temperature). The actual period of use may deviate from this value. It depends on the chosen flow rate, the system configuration and the ambient condi- tions. X-plore 8300...
  • Page 24 The residual capac- The filter capacity is Replace the filter. ity indicator of the almost exhausted filter is flashing red. (< 10 %). The An acoustic signal remaining period of sounds (recurring, use depends on the high tone). ambient conditions. X-plore 8300...
  • Page 25 0 °C to 35 °C. Rechargeable bat- Device must be tery defective checked by Dräger- Service. All symbols are System error Device must be flashing red. An checked by Dräger- acoustic signal Service. sounds (recurring, high tone). X-plore 8300...
  • Page 26 2. Disassemble the carrying system from the blower unit. 3. Clean and disinfect blower unit using disinfectant cloths. Ensure that the junctions to breathing hose and filter are cleaned well. 4. Remove the facepiece, breathing hose, and filter (see "Replacing the filter", page 32). X-plore 8300...
  • Page 27 (temperature: max. +50 °C for 4 hours). Keep away from direct sunlight. 8. Reassemble the cleaned components. Insert a new filter or seal the suction inlet with the plug 3732632. If necessary, seal the hose connection with the plug R59563 until its next use. X-plore 8300...
  • Page 28 4. Remove the facepiece, breathing hose, and filter (see "Replacing the filter", page 32). 5. Seal all the device openings (see Figure E): – Secure the washing plug 3732632 into the suction inlet. – Tightly seal the hose connection using the washing plug 3732631. X-plore 8300...
  • Page 29 "Cleaning a heavily contaminated blower unit", page 28). 2. Clean the blower unit as follows: a. Prepare a cleaning solution containing water and a cleaning agent. b. Put the blower unit into the cleaning bath. c. Rinse the blower unit thoroughly under running water. X-plore 8300...
  • Page 30 – Duration: 5.0 min to 22.0 min - depending on contamination level – Temperature: +55 °C (Suma Jade); +50 °C to +55 °C (neodisher) Rinsing phase (depending on machine type) – Duration: min. 25 s – Temperature: +50 °C to +55 °C X-plore 8300...
  • Page 31 Replace if necessary. 2. Insert the filter into the blower unit and turn clockwise until it locks in place (see Figure G). Make sure you hear a clicking sound. Filter and device must be flush with each other. X-plore 8300...
  • Page 32 6.2.3 Replacing the filter WARNING No protection without filter! ► Do not use the device without filter. CAUTION Damage to blower unit due to penetration of particles! ► When you remove the filter, make sure that no particles enter the device. X-plore 8300...
  • Page 33 8000 washing plug (hose connection). 1. Use the O-ring removal tool to lift the old O-ring out of the groove. 2. Insert new O-ring in the provided groove. 3. If required, lubricate the new O-ring with Molykote 111. X-plore 8300...
  • Page 34 The chargers are only intended for indoor use. Do not charge the rechargeable battery outside. Always disconnect the chargers from the power supply when not in use. X-plore 8300...
  • Page 35 When the rechargeable battery is fully charged, the charger switches automatically to standby. In standby mode, the rechargeable battery stays charged. In this mode, the rechargeable battery is neither overcharged nor damaged. Transport Transport the product in its original packaging. X-plore 8300...
  • Page 36 For further information, please contact the national mar- keting organisations or Dräger. Technical data 10.1 Blower unit Rated period of use 8 hours Minimum duration for EN 1294x approvals, with maximum flow rate: Hoods/helmets/protective visors: 7 hours Masks: 6 hours X-plore 8300...
  • Page 37 60 dB(A) Degree of protection IP 67 Height of use -150 m to +2500 m above sea level X-plore 8300 PAPR unit (uni- versal) Flow rate for hoods/hel- 175/210 L/min mets/protective visors Flow rate for half/full face 120/145 L/min...
  • Page 38 18 V DC +5 % / -5 % Output current 1670 mA Operating temperature 0 °C to +35 °C, ≤ 95 % rela- tive humidity, non-condensing Storage temperature -20 °C to +70 °C, 10 % to 90 % relative humidity X-plore 8300...
  • Page 40 Manufacturer Dräger Safety AG & Co. KGaA Revalstraße 1 D-23560 Lübeck Germany +49 451 8 82-0 9300997 – 1412.893 en © Dräger Safety AG & Co. KGaA Edition: 01 – 2023-09 Subject to alterations  www.draeger.com...