Table 1-6. LCD Status Messages (continued)
Code
Text
E2016
Int Controller
E2017
Timer Fail
E2018
Prog Timer
E2019
Parity Error
E201A
SIO Err
E201B
Kybd Controller
E201C
SMI Init
E201D
Shutdown Test
E201E
POST Mem Test
E201F
DRAC Config
E2020
CPU Config
E2021
Memory
Population
E2022
POST Fail
E2110
MBE Crd # DIMM ##
& ##
Causes
Interrupt controller failure.
Timer refresh failure.
Programmable interval timer
error.
Parity error.
SIO failure.
Keyboard controller failure.
System management interrupt
(SMI) initialization failure.
BIOS shutdown test failure.
BIOS POST memory test failure. See "Troubleshooting System
Dell remote access controller
(DRAC) configuration failure.
CPU configuration failure.
Incorrect memory configuration.
Memory population order
incorrect.
General failure after video.
One of the DIMMs in the set
implicated by "## & ##" has
had a memory multi-bit error
(MBE). If no memory card is
present, the "Crd #" string is left
out of the message.
Corrective Actions
See "Getting Help" on page 147.
See "Getting Help" on page 147.
See "Getting Help" on page 147.
See "Getting Help" on page 147.
See "Getting Help" on page 147.
See "Getting Help" on page 147.
See "Getting Help" on page 147.
See "Getting Help" on page 147.
Memory" on page 120. If problem
persists, see "Getting Help" on
page 147.
Check screen for specific error
messages.
Ensure that DRAC cables and
connectors are properly seated. If
problem persists, see your DRAC
documentation.
Check screen for specific error
messages.
Check screen for specific error
messages. See "Troubleshooting
System Memory" on page 120.
Check screen for specific error
messages.
See "Troubleshooting System
Memory" on page 120.