Removing the Cooling Shroud

1 The cooling shroud is secured with a latch at the end of the shroud. Release the latch by pulling it
towards the outside wall of the chassis. See Figure 3-10.
2 Rotate the shroud upward and toward the front of the system on its hinges, and then lift the shroud
out of the system.
Figure 3-10. Removing and Installing the Cooling Shroud
1
1
shroud pivots (2)
4
shroud hinges (2)

Installing the Cooling Shroud

1 Align the hinges on the shroud pivots located on either end of the fan bracket. See Figure 3-10.
2 Slowly lower the shroud straight down into the system until the fan connector engages and the latches
snap into place.
2
2
cooling shroud
5
fan bracket
4
5
3
release latch