  • Page 1 OASIS DP Reverse Osmosis Units with Made in Italy components INSTRUCTIONS FOR INSTALLATION...
  • Page 2 OASIS DP - Reverse Osmosis Units INSTALLATION, USE AND MAINTENANCE MANUAL Dear Costumer, thanks for choosing this Atlas Filtri product. 1. GENERAL INFORMATION The indications in this manual apply to models: OASIS DP STD OASIS DP PUMP OASIS DP is a device intended to process drinking water able to modify its organoleptic and chemical properties, reducing the saline content while guaranteeing microbiological safety.
  • Page 3 ➥ At the end of the OASIS device working life and relevant cartridges, membranes and UV lamps, discard according to current local law. 2. INSTALLATION 2.1 Preface ➥ Assembly and installation must be performed by qualified personnel according to current local regulations. Before performing any operation, carefully read the instructions in this manual.
  • Page 4 Oasis DP RO operation explained Reverse osmosis is by far the most advanced water purification technology in use today. A special semipermeable membrane structure similar in its properties to the membrane of a living cell is capable of purifying drinking water from virtually all harmful impurities. The membrane can be thought of as having tiny pores, 200 times smaller than viruses and 4000 times smaller than bacteria.
  • Page 5 Permeate Connect to tap Water Flow though Atlas Filtri Oasis RO Unit. Raw water enters the RHS of the triple pre-filter housing under the mounting plate; labeled, FEED WATER IN After Passing through the pre-filters, water exits from the LHS and is piped to a square white block behind the top horizontal filter housings.
  • Page 6 Water flows right to left though the Carbon filter. The inlet fitting of the Carbon Housing is fitted with a Tee. The tee connects to the 12L Pressure tank supplied with unit. From left of Carbon filter, the pipe loops to connect into the Remineralisation filter housing on the LHS.
  • Page 7 2.5 Production installation ➥ Before installation, make sure the plumbing system has been installed as for the exhisting rules of the state of the art. Install a bypass that permits unit's by-passing. Install a check valve from the unit to the water mains. For mains pressure over 8 bar (116 psi) a pressure reducer must be installed upstream from the product.
  • Page 8 2.5.2 Drain bracket installation Install the drain bracket on the sink drain siphon. Make sure the gasket correctly rests on the pipe and that the bolts are tight. Remove the drain pipe fastening nut. Using a drill with a 6mm bit, drill a hole on the drain siphon pipe where the nut was just removed. Insert the drain pipe in the nut by about 2 cm and screw the fastening nut onto the bracket.
  • Page 9 2.5.3 Storage tank installation Place the tank near the machine. Loosen the fastening nut on the tank ball valve. Insert the 1/4" tank connection pipe and tighten the fastening nut. Connect the 1/4" pipe to the machine. 2.5.4 Dedicated tap installation Drill a 12mm diameter hole on the sink bottom (no.
  • Page 10 2.6 Start up ➥ ➥ ➥ The OASIS DP osmotic membrane is supplied dampened with a maintenance s Before using water, run for at least 10 - 15 minutes, flowing from the dedicated tap Prevent the membrane from drying by leaving in the sealed package until use. Install the membrane immediately after opening the package.
  • Page 11 3.2 Osmotic membrane replacement Run water from the tap over the sink to reduce circuit pressure. Disconnect the connection pipe on the RO VESSEL top. Unscrew the RO VESSEL top. With a clamp, remove the membrane. Insert a new membrane. Screw in the RO VESSEL top.
  • Page 12 The average filter cartridge working life varies according to use, environmental conditions, pressure, etc. In general, changes in water taste, odour and colour indicate that the cartridge requires replacement. A. Before opening the container, turn off water supply tap and place a container under the system to collect any water that may spill when the cartridges are removed.
  • Page 13 TROUBLESHOOTING OASIS DP devices are constructed following strict quality controls and are subject to stringent efficiency and resistance tests. Following are a series of problems that may occur due to incorrect installation or maintenance or improper use, possible negligence or due to filter or part wear. •...
  • Page 14 Parameter Value Main pressure (no booster pump), barg (psi) 3-6* (43-87) Main pressure (booster pump installed), barg (psi) 2-4.5 (29-65) Tank bladder pressure, barg (psi) 0.4-0.6** (5.8-8.7) Feed water temperature, °C (°F) +4…+30*** (39...86) Weight of the system (base model), kg (pounds) 6 (13.2) Ambient temperature, °C +5…+40***...
  • Page 15 WATER QUALITY AFTER REVERSE OSMOSIS MEMBRANE* Index Value 5.5-6.5 5-15 ppm Calcium <2 ppm Magnesium <1 ppm Sodium + Potassium <5 ppm * Values are determined under the following conditions: temperature of supply water is 25 °C (77 °F), supply water quality and operation conditions correspond to manufacturer’s requirements.
  • Page 16 DOMESTIC RO Underbench RO Spares & Accessories IMAGE PART NUMBER ITEM CODE DESCRIPTION Double Clip 2.5" ATL-DOUBLECLIP2.5”X2” 807280 for Oasis DP RO Single Clip 2.5" ATL-SINGLECLIP2.5” 807281 for Oasis DP RO Max pressure switch ATL-MAXPRESSURESWITCH 807282 for Oasis DP RO Min pressure switch ATL-MINPRESSURESWITCH 807283...
  • Page 17 Pre-filter cartridge trio kit for Oasis DP RO & ATL-CARTRIDGESKITFOROASISDP 807276 Ecosoft Under Bench RO (5 mic PS, GAC, 5 mic CB) RO 189lpd Membrane ATL-ROMEMBRANE50GPD1812 807277 for Oasis DP RO & Ecosoft Under Bench RO Carbon Post Filter ATL-AICACTIVATEDCARBONPOSTFILTER 807278 for Oasis DP RO &...
  • Page 18 ATLAS FILTRI and SANIC are registered trade marks of ATLAS FILTRI S.r.l. Unauthorized use of the registered trade marks is strictly forbidden and legally persecuted. Images and texts are property of ATLAS FILTRI S.r.l., which reserves the rights to change products design and specification without prior notice.