D V P - E S 2 / E X 2 / E C 5 / S S 2 / S A 2 / S X 2 / S E / S E 2 & T P O p e r a t i o n M a n u a l - P r o g r a m m i n g
For EC5/SE2 Series
Input Point
Pulse output frequency (S)
Pulse output device (D
Directon signal ouptut (D
Reverse pulse output direction
5. PLSV instruction does not support settings for ramp up or ramp down. If ramp up/down process is
required, please use API 67 RAMP instruction.
6. If the drive contact turns off during pulse output process, pulse output will stop immediately.
Program Example:
When M10 = ON, Y0 will output pulses at 20 kHz. Y1 = OFF indicates forward direction.
M10
DPLSV K20000
3 - 5 1 4
Channel
CH0
)
Y0
1
)
Y1
2
M1305
Y0
Y1
CH1
CH2
EC5: -50,000 to +50,000 Hz
SE2: -100,000 to +100,000 Hz
Y2
Y4
Y3
Y5
M1306
M1532
CH3
Y6
Y7
M1533