………………………………………………………………… ENGLISH ………………………………………………………………… EN DVP-ES2 DIDO is an OPEN-TYPE device. It should be installed in a control cabinet free of airborne dust, humidity, electric shock and vibration. To prevent non-maintenance staff from operating DVP-ES2 DIDO, or to prevent an accident from damaging DVP-ES2 DIDO, the control cabinet in which DVP-ES2 DIDO is installed should be equipped with a safeguard.
08XM2 08XP2 08XN2 16XM2 16XP2 16XN2 24XP2 24XN2 32XP2 Model 11R/T 11R/T 11R/T 11R/T 00R/T 00R/T 00R/T Type Digital Input/Output Modules Input spec. Output spec. Model Power input Points Type Points Type DVP08XM211N DVP08XP211R Relay Supplied by DVP08XP211T Transistor bus power...
Page 5
Please install the PLC in an enclosure with sufficient space around it to allow heat dissipation, as shown in the figure. Direct Mounting: Please use M4 screw according to the dimension of the product. DIN Rail Mounting: When mounting the PLC to 35mm DIN rail, be sure to use the retaining clip to stop any side-to-side movement of the PLC and reduce the chance of wires being loose.
Page 6
EXT2 16XP211R X60 ~ X67 Y30 ~ Y37 2.4W 1.2W EXT3 08XP211R X70 ~ X73 Y40 ~ Y43 EXT1 EXT2 EXT3 The input points of the 1 MPU are 36, its input will be defined as 40 and there will be no corresponding input points for the 4 higher numbers.
Page 7
AC Power supply: 100 ~ 240VAC, 50/60Hz ○ Breaker ○ Emergency stop: This button can cut off the system power supply when accidental ○ emergency takes place. ○ Power indicator ○ AC power supply load Power supply circuit protection fuse (2A) DVP-PLC (main processing unit) ○...
Page 8
DC power supply ○ Emergency stop: Uses external switch ○ Fuse: Uses 5 ~ 10A fuse at the shared terminal of output contacts to protect the output ○ circuit Transient voltage suppressor: To extend the life span of contact. ○ 1.
Page 9
The output of the transistor model is “open collector”. ○ 1. Diode suppression: Used when in smaller power (Figure 12) 2. Diode + Zener suppression: Used when in larger power and frequent On/Off (Figure Manually exclusive output: For example, Y3 and Y4 control the forward running and ○...