D V P - E S 2 / E X 2 / E C 5 / S S 2 / S A 2 / S X 2 / S E / S E 2 & T P O p e r a t i o n M a n u a l - P r o g r a m m i n g
Explanations:
When M0 is triggered, Y0 executes pulse output. When external interrupt is detected on X4
after 50,000 pulses, pulse output will perform ramp down process for 10,000 pulses and
then stop. M1108 will be ON. If no interrupt is detected on X4, Y0 pulse output will stop
after 1,000,000 pulses are completed.
Interrupt triggered between 0-50,000 pulses will be invalid, i.e. no ramp-down process will
be performed before 50,000 pulses are achieved.
Points to note:
When Mark function is executed with Mask function, PLC will check the validity of Mask
range first, then ramp-down stop pulses of Mark function. If the above set values exceed
the proper range, PLC will automatically modify the set values after the instruction is
executed.
When PLSR or positioning instructions with ramp-up/down section are enabled, the user
can check the pulses of ramp-up section in DD1127 and pulses of ramp-down section in
DD1133.
Users can perform single speed positioning when ramp-up/down time setting is not
specified.
5.
Adding mask and alignment mark function for CH0 and CH1
Available for the followings
Series
Firmware
version
CH0 and CH1 relative parameters for Mask and Alignment Mark function:
External
Marking
Output
deceleration
number
flag
CH0
M1156
(Y0/Y1)
CH1
M1158
(Y2/Y3)
3 - 1 7 0
ES2/
ES2-E/
ES2-C
EX2
SE2
V3.28
V3.28
V1.00
Ramp-up
Ramp-down
input
time
time
point
X4
D1343
D1348
X6
D1353
D1349
12SA2/
SS2
12SE
SX2
V2.82
V3.28
V2.02
Number of ramp-
Starting/
down pulses
Stopping
frequency
after marking
D1340
D1232/D1233
D1352
D1234/D1235
26SE
28SA2
V2.0
V2.9
Front
Back
masking
masking
D1026
D1100
D1027
D1101
D1135
D1102
D1136
D1103