Download Print this page
BONAIRE PRC6000026 Operation & Installation Manual

BONAIRE PRC6000026 Operation & Installation Manual

Optima portable room air conditioner 2.6kw

Advertisement

Quick Links

REFRIGERANT
PRC6000026 Optima Portable Room Air Conditioner 2.6KW
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the PRC6000026 and is the answer not in the manual?

Questions and answers

Summary of Contents for BONAIRE PRC6000026

  • Page 1 REFRIGERANT PRC6000026 Optima Portable Room Air Conditioner 2.6KW Page 1...
  • Page 2 R290 Refrigerant is Higley Flammable refrigerant REFRIGERANT Page 2...
  • Page 3 TABLE OF CONTENTS Safety & Important Information Page 4-9 Safety & Information Specifications Page 10 Product Technical Specifications Air Conditioner Basics Page 11 Product Major Compents Control Panel Page 12 Basic Operations Control Remote Control Page 13-14 Remote Function Care & Maintenance Page 15-18 Storage &...
  • Page 4 DO NOT coil or bundle the electric cord to reduce its length as overheating of the cord may occur which could result in a fire hazard. The flexible cord and plug must not be modified. If the cord or plug are damaged, they mustbe replaced by Bonaire, or a Bonaire appointed service agent.
  • Page 5 The appliance must be installed, used and stored in a ventilated area with the below specified area PRC6000026 Optima Portable Room Air Conditioner 2.6KW must be stored in an area more than 7.7 m2 When cleaning the appliance, do not use any tools other than those recommended by the...
  • Page 6 SAFETY & IMPORTANT INFORMATION EXPLANATION OF SYMBOLS DISPLAYED ON THE UNIT Warning WARNING Risk of fire / flammable material. If the refrigerant is leaked, together with an external ignition source, there is a possibility of ignition. Read the OPERATING INSTRUCTIONS carefully before operation. Service personnel are required to carefully read the OPERATING INSTRUCTIONS and INSTALLATION MANUAL before operation.
  • Page 7 SAFETY & IMPORTANT INFORMATION No ignition sources No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion.
  • Page 8 SAFETY & IMPORTANT INFORMATION Repair to intrinsically safe components Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere.
  • Page 9 SAFETY & IMPORTANT INFORMATION Decommissioning Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant.
  • Page 10 SPECIFICATION INTRODUCTION This portable air conditioner can alter the room temperature and humidity. It has multiple functions of cooling dehumidifying (drying) and fan ventilation and can be moved from room to room and transported from building to building easily. The air conditioner can maintain set room indoor air temperatures between 15°C and 32°C. The set room temperature is displayed on the remote control and in the control panel on the unit.
  • Page 11 AIR CONDITIONER BASICS Page 11...
  • Page 12 OPERATION Page 12...
  • Page 13 REMOTE CONTROLLER 1. ON/OFF Button 2. Fan Only Button 3. Swing Button 4. Timer Button 5. Temperature UP/DOWN Buttons 6. Sleep Button 7. Mode Button. Page 13...
  • Page 14 REMOTE CONTROLLER How to install batteries? The installation direction of AAA battery shall be determined according to the positive and negative poles of the battery. At the same time, the battery compartment to be installed also has installation prompts. After the positive and negative poles are confirmed, insert the battery. Installation steps: The one with "+"...
  • Page 15 CARE & MAINTENANCE Page 15...
  • Page 16 CARE & MAINTENANCE Page 16...
  • Page 17 CARE & MAINTENANCE Page 17...
  • Page 18 CARE & MAINTENANCE SAVE A SERVICE CALL Page 18...
  • Page 19 INSTALLATION Page 19...
  • Page 20 INSTALLATION Page 20...
  • Page 21 EXPLODED VIEW Page 21...
  • Page 22 EXPLODED VIEW Page 22...
  • Page 23 WARRANTY INFORMATION Product Sr. No. The warranties contained in this document ("the warranty") are provided voluntarily by Climate Technologies (as manufacturer) to you (as consumer) in relation to your purchase of a product from Climate Technologies ("the product") and are in addition to any rights you may have under the Australian Consumer Law or other applicable legislation.
  • Page 24 • The appliance must not be modified or changed in any way. • Your proof of purchase MUST be produced before free service will be provided together with a valid serial number. • The product must be registered within 30 days of purchase by following the instructions listed in the following page.
  • Page 25 Technologies to proceed with the remedial action prescribed under this warranty. Service Hotline: 1300 665087 e-mail us: service@climtech.com.au Book a request online at: www.bonaire.com.au/support Warranty on Replacement Parts Parts replaced under warranty are warranted for the balance of the original warranty period.
  • Page 26 Scan the QR code below using your mobile device and follow the fill out the online warranty registration form. Option2 Visit our website at: www.bonaire.com.au/service and complete our online warranty registration form. Option3 Fill out the details below and post this page together with a copy of your proof of purchase to:...
  • Page 27 Copyright© Climate Technologies Pty Ltd. April 2024. All rights reserved. The product specifications in this booklet apply to the specific products and models described at the date of issue. Under our policy of continuous product improvement, these specifications change at any time.