CALIBRATION PROCEDURE
NI PXIe-4145
Four Channel Precision Source-Measure Unit (SMU)
This document contains the verification and adjustment procedures for the NI PXIe-4145
(NI 4145). Refer to
Contents
Verification................................................................................................................................2
Required Software.............................................................................................................2
Related Documentation.....................................................................................................2
Password........................................................................................................................... 2
Calibration Interval........................................................................................................... 2
Test Equipment..................................................................................................................2
Test Conditions..................................................................................................................3
Calibration Overview........................................................................................................ 4
Self-Calibrating................................................................................................................. 5
Voltage Output and Measurement.....................................................................................5
Current Output and Measurement.....................................................................................7
Remote Sense.................................................................................................................... 9
Adjustment.............................................................................................................................. 10
Adjusted Specifications...................................................................................................10
Self-Calibrating............................................................................................................... 11
Initiating the Adjustment Session................................................................................... 11
Connecting and Configuring Equipment for Voltage Adjustment.................................. 11
Adjusting Voltage Measurement..................................................................................... 12
Connecting and Configuring Equipment for Current Adjustment..................................13
Adjusting Current Measurement..................................................................................... 13
Connecting and Configuring Equipment to Adjust Residual Offset Voltage..................14
Adjusting Residual Voltage Offset..................................................................................15
Adjusting Residual Current Offset..................................................................................15
Closing the Adjustment Session..................................................................................... 15
Alternative to Adjustment Procedures............................................................................ 15
Reverification..........................................................................................................................16
Worldwide Support and Services............................................................................................ 16
ni.com/calibration
for more information about calibration solutions.