Page 15
Manual, it may entail cancellation of personnel of potentially hazardous codes. warranty and liabilities by The Trane situations which, if not avoided, Company. COULD result in death or serious injury.
Page 16
Contents General Information Indoor Unit Installation Outdoor Unit Installation Connection of Refrigerant Tubing and Condensate Drain Piping Leak Check and System Evacuation Electrical Installation Wiring Diagram Dimensional Data Notes MCC-SVN01A MCC-SVN01A.indd 16 MCC-SVN01A.indd 16 4/3/13 1:41:06 PM 4/3/13 1:41:06 PM...
Page 19
Indoor Unit Installation Where to install Indoor Unit • Hang the four mounting rods to the • Install the leveling metal plate to positions marked as picture shown adjust the gap between the unit • There should not be any heat in figure 3 (using twelve nuts and and a ceiling, fixing the screws source or steam near the unit.
Page 20
Outdoor Unit Installation Where to install Outdoor more than 10 cm. more than 10 cm. Unit • The foundation must be solid enough to bear the weight and more than 10 cm. vibration of the unit. • The space around the unit is more than 35 cm.
Page 21
Connection of Refrigerant Tubing and Condensate Drain Piping Connecting the unit with flaring A good flare should have the 10. Tighten the flare nut to the specified tightening torque with procedure following characteristics: torque wrench and adjustable 1. Flaring (If piping is procured or cut Inside surface is glossy and wrench.
Page 22
Leak Check and System Evacuation Leak Check 8. Close valve on the R-22 supply Procedure cylinder. Close valves on manifold After the connection operation of 1. Connect R-22 drum with gauge gauge set and remove refrigerant refrigerant lines to both the outdoor manifold to the Schrader valves charging hoses from liquid and and indoor unit is completed, the field...
Page 23
Electrical Installation All wiring and grounding must comply Indoor Unit with local electrical codes. Remove the right side panel and 1. Wiring return grille (see previous instructions), Important Safeguards: to access the terminal base. - Check the unit nameplate for Pass the system wiring through electrical rating.
Page 28
999/1 Moo 9 Bangna-Trad km.19 Road, Bangchalong, Bangplee, Samutprakarn 10540 Õ”‡¿Õ∫“ßæ≈’ ®— ß À«— ¥ ¡ÿ ∑ √ª√“°“√ 10540 Trane has a policy of continuous product and product data improvement and reserves the right to change www.tranethailand.com design and specifications without notice.