Download Print this page
Hide thumbs Also See for Rad-icon 1520:

Advertisement

Quick Links

Teledyne DALSA
Rad-icon 1520
Detector User Manual
GigE models
December 28, 2015
www.TeledyneDALSA.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the Rad-icon 1520 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dalsa Rad-icon 1520

  • Page 1 Teledyne DALSA Rad-icon 1520 Detector User Manual GigE models December 28, 2015 www.TeledyneDALSA.com...
  • Page 2 © 2015 Teled yne DALSA. All inform ation provid ed in this manual is believed to be accurate and reliable. N o responsibility is assum ed by Teled yne DALSA for its use. Teled yne DALSA reserves the right to make changes to this information w ithout notice.
  • Page 3 Rad-icon 1520 GigE User Manual Contents System Precautions and Safety _________________________________________________ 4 Safety Information ..................... 4 EMC compliance ....................5 System precautions ................... 5 Detector Maintenance ..................6 The Rad-icon Detector ________________________________________________________ 8 Detector Highlights ....................8 Setting up the Detector ________________________________________________________ 9 Detector Connectors and Cables ................
  • Page 4 . Teled yne DALSA assu m es no responsibility for the u ser‟s failu re to com ply w ith these requ irem ents.
  • Page 5 Stacking Teled yne DALSA d oes not recom m end that the u ser stack the prod u ct or u se it in ad jacent to other equ ipm ent. If this ar rangem ent is u navoid able, then the (End -)u ser m u st ensu re that there is ad equ ate airflow arou nd the d etector and that norm al operation cond itions are m aintained .
  • Page 6 The u se of accessories, pow er su p plies and cables other than those specified , w ith the exception of cables sold by Teled yne DALSA as replacem ent parts, m ay resu lt in increased em ission or d ecreased im m u nity of the Rad -icon 1520 Detector.
  • Page 7 Rad-icon 1520 GigE User Manual Cleaning the Detector Body and Front Cover The d etector bod y and front cover can be cleaned w ith a m ild , no n-abrasive cleanser su ch as isop ropyl alcohol. Place a sm all am ou nt of cleanser on a soft cloth and ru b gently over the d etector bod y su rface.
  • Page 8 GigE band w id th, faster fram e rates u p to 19-20 fps m ay be achievable)  GigE d ata interface  Gad ox scintillator Programmability  Exposu re tim e  Read -ou t m od e  Trigger m od es Rad-icon 1520 Detector Teledyne DALSA...
  • Page 9 Rad-icon 1520 GigE User Manual Setting up the Detector Detector Connectors and Cables This d etector u ses the follow ing connectors.  An RJ-45 connector for Gigabit Ethernet signals, d ata signals CAT6 Ethernet cable  One 2-pin Lem o connector for pow er Lem o EXG.0B.302.H LN...
  • Page 10 (assu m ing pow er has been properly ap plied ). WARN IN G: When setting u p the d etector pow er su p plies follow these gu id elines: Rad-icon 1520 Detector Teledyne DALSA...
  • Page 11 Rad-icon 1520 GigE User Manual  Ap ply the ap propriate voltages.  Keep lead s as short as possible in ord er to red u ce voltage d rop. The voltage level at the prod u ct p ow er connector shou ld be w ithin the range m entioned in the d atasheet.
  • Page 12 PCI Express slot. Teled yne DALSA ad vises to u se the Intel Gigabit CT ad apter N etw ork Interface Card (N IC) w hich is a low cost bu t high perform ance and reliable ad apter w ith a PCI Express slot.
  • Page 13 GigE d river and / or the Shad oCam softw are. To obtain the latest versions, or softw are for a new er operation system , it m ay be necessary to go to the Teled yne DALSA w e bsite for the latest u pd ates.
  • Page 14 CPU u sage. In m ost situ ations, extra latency introd u ced by interru pt m od eration is very low and thu s the gain on CPU perform ance becom es m ore beneficial. Rad-icon 1520 Detector Teledyne DALSA...
  • Page 15 Rad-icon 1520 GigE User Manual Receive Buffers Und er certain cond itions the host PC system CPU m ay be bu sy w ith tasks other than the im aging application. Incom ing im age packets rem ain in the PC m em ory allocated to store packets instead of im m ed iately being copied into the im age b u ffer.
  • Page 16 N etw ork Interface Card on host system to w hich the d etector is connected The d efau lt assigned d etector IP ad d ress can be m od ified u sing the Teled yne DALSA N etw ork Configu ration Tool, w hich is part of the installation package.
  • Page 17  Refer to the Teled yne DALSA N etw ork Im aging p ackage m anu al if error m essages are show n in the Ou tpu t Messages pane. Bu t first, increase the valu e of the Interpacket Delay featu re available from the GigE Vision TransportLayer Category grou p in Cam Expert.
  • Page 18 To stop a Grab process the u ser m u st press the Freeze bu tton. After the Freeze bu tton is pressed the d etector ignores any ad d itional triggers and no ad d itional im ages are acqu ired . Rad-icon 1520 Detector Teledyne DALSA...
  • Page 19 Rad-icon 1520 GigE User Manual Operational reference Using CamExpert with the Rad-icon Detector The Sapera Cam Expert tool is the interfacing tool for GigE Vision d etectors and cam eras, and is su p ported by the Sapera library and hard w are. When u sed w ith a Rad -icon d etector, Cam Expert allow s a u ser to test m ost of the operating m od es.
  • Page 20 D isplay pane: Provid es a live or single fram e acqu isition d isplay. Fram e bu ffer param eters are show n in an inform ation bar above the im age w ind ow . Rad-icon 1520 Detector Teledyne DALSA...
  • Page 21 Rad-icon 1520 GigE User Manual  Control Buttons: The Display pane inclu d es Cam Expert control bu ttons. These are:  Output pane: Displays m essages from Cam Expert or the GigE Vision d river. CamExpert View Parameters Option All d etector featu res have a Visibility attribu te w hich d efines its requ irem ent or com plexity.
  • Page 22 (RW) Load factory default feature Factory Setting FactorySetting settings. Select the user defined UserSet1 UserSet1 configuration UserSet 1 as the Power-up Configuration. Select the user defined UserSet2 UserSet2 configuration UserSet 2 as the Power-up Configuration. Rad-icon 1520 Detector Teledyne DALSA...
  • Page 23 Rad-icon 1520 GigE User Manual Display Name Feature Description Selects the camera configuration set to load feature settings from User Set Selector UserSetSelector or save current feature settings to. The Factory set contains default camera feature settings. Select the default camera feature...
  • Page 24 Set 1 or 2 and click Save. Select a saved u ser set an d click Load to restore a saved configu ration. N ote: A firm w are reboot (pow er cycling) m ay be requ ired after resetting the u ser set configu ration to the Factory Setting. Rad-icon 1520 Detector Teledyne DALSA...
  • Page 25 Rad-icon 1520 GigE User Manual Detector Control The Rad -icon Detector controls, as show n by Cam Expert, grou ps the d etector-specific param eters. The featu res w hich are u nd erlined link to the paragrap h w hich d escribe s these featu res in m ore d etail.
  • Page 26 The m inim u m fram e period of a 2x2 binned fram e is 30 m illisecond s. N ote that the m inim u m “Extend ed Exp osu re” setting for 2x2 binned m od e is 12500. Rad-icon 1520 Detector Teledyne DALSA...
  • Page 27 Rad-icon 1520 GigE User Manual Region of Interest With Region of Interest (ROI) a region in the pixel array can be selected to read -ou t from the pixel array from the sensor and transferred to the host system as show n in the figu re below .
  • Page 28 A: Integration Time B + C B + C B + C B: Read-out Time 40 ms 17.5 ms varies C: Extended Exposure 21 ms – 65 sec 12.5ms – 65sec 0 ms – 65 sec Rad-icon 1520 Detector Teledyne DALSA...
  • Page 29 Rad-icon 1520 GigE User Manual Triggered (External) Mode In this m od e the d etector w ill take a single im age at the m om ent a trigger signal is ap plied to the d etector. This m od e is equ al to the Snap shot m od e bu t no reset is need ed before integration can start.
  • Page 30 Trigger input high B: Read-out Time 40 ms 17.5 ms varies C: Exposure Time = Trigger Output A - D D: Reset Time E: Minimal Trigger In high > D F: Minimal Trigger In low > B Rad-icon 1520 Detector Teledyne DALSA...
  • Page 31 Rad-icon 1520 GigE User Manual Image Format Control The Rad -icon Im age Form at controls, as show n by Cam Expert, grou p p aram eters u sed that give inform ation abou t the resolu tion and pixel form at.
  • Page 32 A first im age acqu ired after long tim e in stand by m od e m ight contain u nw anted signal. It is recom m end ed to read and d iscard at least 2 im ages after stand by. Rad-icon 1520 Detector Teledyne DALSA...
  • Page 33 Rad-icon 1520 GigE User Manual Mechanical Interface Mechanical Dimensions 36.0 mm 229.3 mm 10.7 mm 207.0 mm First Row Pixel 0,0 Butting Gap Pixel 2064,1548 M6 mounting hole 6 mm deep (6x) Last Row 24.2 mm (2x) 106.5 mm (2x) 206.1 mm (2x)