Advertisement

Quick Links

Square Bakery Cases
Models:
Refrigerated Bakery Models
#193BCF36B
36" Black
#193BCF36W
36" White
#193BCF48B
48" Black
#193BCF48W
48" White
#193BCF60B
60" Black
#193BCF60W
60" White
#193BCF72B
72" Black
#193BCF72W
72" White
Note:
Read this manual in its entirety prior to equipment setup, operation, and maintenance.
www.AvantcoRefrigeration.com
User Manual
Dry Bakery Models
#193BCFD36B
36" Black
#193BCFD36W
36" White
#193BCFD48B
48" Black
#193BCFD48W
48" White
#193BCFD60B
60" Black
#193BCFD60W
60" White
#193BCFD72B
72" Black
#193BCFD72W
72" White
09/2024

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 193BCF36B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Avantco 193BCF36B

  • Page 1 User Manual 09/2024 Square Bakery Cases Models: Refrigerated Bakery Models Dry Bakery Models #193BCF36B 36" Black #193BCFD36B 36" Black #193BCF36W 36" White #193BCFD36W 36" White #193BCF48B 48" Black #193BCFD48B 48" Black #193BCF48W 48" White #193BCFD48W 48" White #193BCF60B 60" Black #193BCFD60B 60"...
  • Page 2: Table Of Contents

    User Manual Square Bakery Cases Table of Contents Warnings ..........................3 Structure & Components ....................4 Installation ......................... 4 Temperature Controls ....................6 Operation .......................... 7 Maintenance ........................8 Safety & Warning ......................9 Troubleshooting ....................... 10 NEMA 5-15P 5001766 5001766 www.AvantcoRefrigeration.com...
  • Page 3: Warnings

    User Manual Square Bakery Cases Warnings DANGER – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BY TRAINED SERVICE PERSONNEL. DO NOT PUNCTURE REFRIGERANT TUBING. PELIGRO – RIESGO DE INCENDIO O EXPLOSION. REFRIGERANTE INFLAMABLE UTILIZADO. PARA SER REPARADO SOLAMENTE POR PERSONAL DE SERVICIO CALIFICADO.
  • Page 4: Structure & Components

    User Manual Square Bakery Cases Structure & Components Merchandising Sliding Rear Shelves Glass Doors The height of the shelf is adjustable for various goods. For Adjustment: Air Suction 1. Take out the shelf. 2. Move the shelf support (Refrigerated Only) to suitable height.
  • Page 5: Cabinet Location Guidelines

    User Manual Square Bakery Cases Cabinet Location Guidelines • Install the unit on strong and leveled surface. • If the surface is uneven, the unit may be noisy. • The unit may malfunction if the surface is uneven. • Install the unit in an indoor, well-ventilated area. •...
  • Page 6: Temperature Controls

    User Manual Square Bakery Cases Temperature Controls Defrost Fan Working Cleaning Heater Compressor Compressor Light Data Fan Working Defrost Lock Status LED HEAT COOL Energy Saving Status LED Storage Pipe High Evaporation Compressor leakage temp. abnormal temp. abnormal temp. protection temp.
  • Page 7: Operation

    User Manual Square Bakery Cases Operation Defrost System Automatic Defrost Cycle • Refrigerator coils are kept below the freezing point (32°F). • During compressor downtime, the evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil temperature above the freezing point, melting any accumulated frost.
  • Page 8: Maintenance

    User Manual Square Bakery Cases Maintenance DISCONNECT POWER CORD BEFORE CLEANING ANY PARTS OF THE UNIT. NOTE: It is strongly recommended that any servicing of the unit be performed by an authorized service technician. Cleaning the Fan Blades and Motor •...
  • Page 9: Safety & Warning

    User Manual Square Bakery Cases Safety & Warning Pay close attention to the safety notices in this section. Disregarding these notices may lead to serious injury and/or damage to the unit. • To minimize shock and fire hazards, be sure to not overload outlet. This unit should be given its own outlet.
  • Page 10: Troubleshooting

    User Manual Square Bakery Cases Troubleshooting Problem Possible Cause Possible Solution Fuse blown or circuit breaker Replace fuse or reset circuit breaker. tripped. Power cord unplugged. Plug in power cord. Compressor not running. Thermostat set too high. Set thermostat to lower temperature. Cabinet in defrost cycle.

Table of Contents