Advertisement

Quick Links

Batteries
OWNER'S MANUAL
www.enersys.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the powerbloc dry and is the answer not in the manual?

Questions and answers

Summary of Contents for EnerSys powerbloc dry

  • Page 1 Batteries OWNER’S MANUAL www.enersys.com...
  • Page 2: Table Of Contents

    CONTENTS Introduction ...........3 Rating Data ..........4 Safety Precautions .........4 Commissioning ........5 Operation ..........6 Discharge ..........6 Charge ............7 Normal Charge ........7 Equalising Charge ........7 Battery Check .........8 Maintenance ..........8 Storage and Transportation ....9...
  • Page 3: Introduction

    Proper instruction and training of all users must be ensured prior to any contact with the battery system. For service, contact your sales representative or call: EnerSys EMEA EnerSys World Headquarters EH Europe GmbH 2366 Bernville Road Baarerstrasse 18 Reading, PA 19605, USA...
  • Page 4: Rating Data

    RATING DATA & SAFETY Motive power batteries for small traction. Sealed gas recombination monoblocs MFP series: gel technology Rating Data Powerbloc™Dry batteries of the MFP series 1. Nominal capacity C See type are valve-regulated lead-acid batteries. Unlike 2. Nominal voltage: See type conventional batteries with liquid electrolyte, 3.
  • Page 5: Commissioning

    SAFETY & COMMISSIONING Safety Precautions (cont.) • Risk of explosion and fire! • Avoid short circuits: do not use non-insulated tools, and do not place or drop metal objects on top of the battery. Remove rings, wristwatches, and articles of clothing with metal parts that might come into contact with the battery terminals.
  • Page 6: Operation

    OPERATION & DISCHARGING Commissioning (cont.) After connecting, the terminals must be covered Flat pole M6 DIN conic post with grease as protection against external corrosion. The specified torque loading for the bolts/screws of 6 ± 1 Nm 8 ± 1 Nm the end cables and connectors are in the table at the Type of monobloc Specific value...
  • Page 7: Charge

    CHARGING & EQUALISING Charge Powerbloc™Dry batteries can be recharged opened or removed. With the charger switched with 50 Hz or HF chargers. If you wish to use off, connect up the battery, ensuring that the an existing charger with WUIa or IUIa profile, polarity is correct (positive to positive, negative you should check that the profile is approved to negative).
  • Page 8: Battery Check

    MAINTENANCE Battery Check After a normal charge, measure: NOTE: Measure at the constant intensity • the total voltage of I=0.033 C5 or if the charger can do it, at • the voltage per cell “equalising charge” . The voltages for a new battery will be greater than or equal to 2.65 Volts per cell under I=0,033 C Maintenance...
  • Page 9: Storage And Transportation

    STORAGE Storage and Transportation Batteries must always be stored and transported The storage time is to be considered within the securely in a vertical position to avoid any battery life expectancy. electrolyte leakage. To ensure the battery is always ready for use, a Store the battery in a fully charged condition in a choice of charging methods can be made : dry, clean, and frost-free area.
  • Page 10 © 2024 EnerSys. All rights reserved. Unauthorised distribution prohibited. Trademarks and logos are the property of EnerSys and its affiliates except CE and UKCA, which are not the property of EnerSys. Subject to revisions without prior notice. E.&O.E. EMEA-EN-OM-PBD-1124...