IC Cylinder and Levers - Installation / Removal
Corbin Russwin Interchangeable Cores (C6, CL6, CT6, CTP, C7, CL7, CT7)
Small Format Interchangeable Cores SFIC (M08) . Schlage LFIC (M69) . ASSA ABLOY ACCENTRA LFIC (YRC, YRC7)
a
Remove IC Core
1. Insert control key and turn counter clockwise until stop is
reached.
2. With key in this position, pull out core.
3. Remove key.
b
Remove IC Core Lever
1. Remove control cylinder (as above).
2. Remove 6 lobe security set screw.
3. Use a flat blade screwdriver to rotate cam within lever sleeve
45°clockwise to align lever catch slot with lever catch button.
(See cam orientation page 7 step 7).
4. Depress catch and remove lever.
c
Install IC Core Lever
1. Assemble lever onto sleeve.
Note:
If IC core is available, insert it into the lever first (see 13D).
2. Use a flat blade screwdriver (or, with the IC core in the lever,
use the key and turn to engage the tailpiece andslot) to
rotate cam within lever sleeve 45° clockwise toalign wide
slot with lever retainer catch.
3. Push lever until catch engages. Check engagement.
4. Secure with 6 lobe security set screw.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2016, 2019, 2024, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights
reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY
Access and Egress Hardware Group, Inc. is prohibited.
2
Figure 16
2
5
Press catch
3
4
2
3
1
10
TM
1
Press catch
4
3
OR
FM345 06/24
Need help?
Do you have a question about the Corbin Russwin CL3100 Series and is the answer not in the manual?
Questions and answers