CEILING
FIRESTOP
ROUND CEILING
SUPPORT/WALL
THIMBLE COVER
PIPE
SECTION
PIPE
SECTION
Figure 3
rise on the building exterior.
PLANNING YOUR
INSTALLATION
There are two basic types of
DirectVent Pro installations. Check the
appliance manufacturer's installation
LQVWUXFWLRQV WR FRQ¿UP ZKDW W\SHV
of installations are permitted and
check for any venting restrictions
such as maximum horizontal run, and
minimum or maximum vertical rise.
6
VERTICAL
The two types of installations are:
HIGH WIND
• Horizontal Termination (Figs. 1 and 2)
TERMINATION
CAP SHOWN
• Vertical Termination (Fig. 3)
When planning your installation,
it will be necessary to select the
STORM
COLLAR
proper length of vent pipe for
your particular requirements. For
horizontal installations, check the
ROOF
FLASHING
appliance manufacturer's installations
instructions to determine the
minimum clearance from the rear of
the appliance to the wall. It is also
important to note the wall thickness.
Select the amount of vertical rise
desired or required, for "vertical-to-
CATHEDRAL
CEILING
horizontal" installations (verify that it
SUPPORT BOX
is within the appliance manufacturer's
minimum and maximum limits). To
determine the length of vent pipe
required for vertical installations,
measure the distance from the
DSSOLDQFH ÀXH RXWOHW WR WKH FHLOLQJ
APPLIANCE
ADAPTOR
the ceiling thickness, the vertical rise
in an attic or second story, and allow
IRU VX FLHQW YHQW KHLJKW DERYH WKH
URRÀLQH )RU WZRVWRU\ DSSOLFDWLRQV
)LUHVWRSV DUH UHTXLUHG DW HDFK ÀRRU
FHLOLQJ OHYHO ,I DQ R VHW LV QHHGHG LQ
the attic, additional pipe and elbows
will be required.
HORIZONTAL INSTALLATION
Step 1. Set the gas appliance in its
desired location. Check to determine
if wall studs or roof rafters are in
the way once the venting system
is attached. If this is the case, you
may want to adjust the location of the
appliance.
Step 2. DirectVent Pro pipe and
¿WWLQJV DUH GHVLJQHG ZLWK VSHFLDO WZLVW
lock connections. To connect the
YHQWLQJ V\VWHP WR WKH DSSOLDQFH ÀXH

Advertisement