APPLICATION
These instructions apply to the
DuraVent DirectVent Pro 4"x6-5/8" and
5"x8" systems. This venting system,
in combination with the gas appliance,
has been tested and listed as a
decorative gas appliance system or as
a direct vent heater system by a major
testing agency such as UL, AGA,
CGA, OMNI, or Warnock Hersey.
Check the manufacturer's rating plate
DQG LQVWUXFWLRQ PDQXDO WR FRQ¿UP WKDW
the DuraVent Direct Vent is approved
for use on the brand name appliance
you have selected.
IMPORTANT
Read all instructions carefully before
starting the installation. Failure to follow
WKHVH LQVWUXFWLRQV PD\ FUHDWH D ¿UH RU
other safety hazard and will void the
warranty. Check with the appliance
manufacturer's installation
LQVWUXFWLRQV IRU VSHFL¿F YHQWLQJ
and clearance to combustible
UHTXLUHPHQWV ZKLFK PD\ YDU\ IURP
one appliance to another. Be sure
to comply with minimum or maximum
distances of vertical or horizontal
runs as prescribed in the appliance
manufacturer's installation instructions.
NON-COMBUSTIBLE
INSULATIONS
The appliance manufacturer may
approve the use of non-combustible
insulation within the clearance to
combustibles distance between a
passthrough leading to the exterior
of a building or within the Wall
Thimble. Check with the appliance
manufacturer's installation instructions
¿UVW 7KH QRQFRPEXVWLEOH LQVXODWLRQ
used must be listed / compliant
with ASTM E136/ULC S114 as
non-combustible, have a melting
temperature above 2000°F/1100°C,
be water resistant with low moisture
absorbtion and be acceptable to
the AHJ. Acceptable insulations
include those made from stone
(aka "rockwool" or "mineral wool"
insulations).
1RWH )LEHUJODVV LQVXODWLRQ LV 127
DSSURYHG
WARNING
• Always maintain required clearances
to nearby combustibles to prevent
D ¿UH KD]DUG %H VXUH WR FKHFN
the appliance manufacturer's
installation instructions for minimum
clearance requirements between
the outer walls of the vent pipe and
nearby combustible surfaces. Be
sure to check the vent termination
clearance requirements from decks,
ZLQGRZV VR WV JDV UHJXODWRUV DLU
supply inlets, and public walkways,
DV VSHFL¿HG LQ WKHVH LQVWDOODWLRQ
instructions and local building codes.
• The gas appliance and vent system
must be vented directly to the outside
of the building, and never be attached
to a chimney serving a separate solid
fuel or gas-burning appliance. Each
direct vent gas appliance must use its
own separate vent system. Common
vent systems are prohibited.
SAFETY PRECAUTIONS
FOR THE INSTALLER
• Wear gloves and safety glasses for
protection.