Summary of Contents for THERMOROSSI ECOTHERM 5000TCOM
Page 1
ECOTHERM 5000TCOM ITA - MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE. FRA - MANUEL D’INSTALLATION, D’UTILISATION ET ENTRETIEN. ENG - INSTALLATION, USE AND MAINTENANCE GUIDE. DEU - INSTALLATIONS-, BETRIEBS- UND WARTUNGSANLEITUNG. ESP - MANUAL DE INSTALACIÓN USO Y MANTENIMIENTO. ITA - Informazioni importanti per la sicurezza ed il corretto funzionamento.
Page 2
Installation, use and maintenance guide ECOTHERM 5000TCOM Page 1...
Installation, use and maintenance guide ECOTHERM 5000TCOM INDEX 1 – INTRODUCTION..........................5 2 – TECHNICAL CHARACTERISTICS...................... 7 3 – GENERAL DESCRIPTION ........................8 4 – INSTALLATION ........................... 9 5 – DESCRIPTION OF THE CONTROLS ....................10 6 – USE OF THE APPLIANCE .........................15 7 –...
Page 4
DECLARATION OF PERFORMANCE ACCORDING TO REGULATION (EU) 305/2011 Codice di identificazione unico del prodotto-tipo: ECOTHERM 5000TCOM Modello, lotto, serie ai sensi dell'articolo 11, paragrafo 4: ECOTHERM 5000TCOM Unique identification code of the product type: Model, batch or serial number required under Article 11(4):...
Page 5
Installation, use and maintenance guide ECOTHERM 5000TCOM IT – SCHEDA PRODOTTO (UE 2015/1186) IT – MARCHIO EN – PRODUCT FICHE (EU 2015/1186) EN – BRAND FR – FICHE PRODUIT (UE 2015/1186) FR – MARQUE THERMOROSSI S.P.A. NL – PRODUCTGEGEVENSBLAD (EU 2015/1186) NL –...
Furthermore, Thermorossi reserves the right to apply changes to the content of this manual anytime and without notice. Thermorossi S.p.A. retains copyright on this manual. These instructions may not be reproduced or communicated to third parties or used in any other way without the necessary authorisation.
Installation, use and maintenance guide ECOTHERM 5000TCOM ATTENTION: the firebox door must always remain shut tight when the appliance is operating. It is strictly forbidden to open the firebox door while the appliance is in operation. While the appliance is in operation the smoke exhaust pipes and some parts of the appliance itself can reach extremely high temperatures: do not touch them! Do not expose your body to hot air for long, do not overheat the room in which the appliance is installed, as these actions could cause health problems.
Installation, use and maintenance guide ECOTHERM 5000TCOM 3 – GENERAL DESCRIPTION 3.1 OPERATING TECHNOLOGY Your appliance has been built to fully satisfy all your heating and practical requirements. Top-grade components and functions managed with microprocessor technology guarantee high reliability and optimal performance.
Installation, use and maintenance guide ECOTHERM 5000TCOM 4 – INSTALLATION 4.1 APPLIANCE LOCATION Follow the general guidelines set out in paragraph 1.1 to the letter. Keep in mind that the flooring of the room in which the appliance is to be installed must withstand the total weight of the appliance combined with the pellets contained in the tank and the weight of the casing.
Installation, use and maintenance guide ECOTHERM 5000TCOM 5 – DESCRIPTION OF THE CONTROLS The appliance, when operating, could be hot to the touch, particularly the door of the combustion chamber: take care when handling the appliance components. Your appliance has obtained the CE marking and has been made to run for at least one hour to check that it functions correctly.
Installation, use and maintenance guide ECOTHERM 5000TCOM Display The following information can appear on the display: Displays the preset combustion power, and consequently the pellet consumption, by the number of bars that are lit up around the flame symbol, using this logic: One bar lit: Minimum combustion power (and therefore with minimum pellet consumption).
Installation, use and maintenance guide ECOTHERM 5000TCOM 3) Now press the Scroll Buttons to change the day of the week; each number corresponds to one day of the week (e.g. 1 corresponds to Monday, 2 corresponds to Tuesday, etc...). To confirm the selection of the day of the week press the Flame Button.
Page 14
Installation, use and maintenance guide ECOTHERM 5000TCOM At this point the second ON/OFF cycle for the selected day has been set. The following screen will appear: At this point if no further programming is required for that day go to point 6-A.
Installation, use and maintenance guide ECOTHERM 5000TCOM Resetting the programmed cycles: Moreover, it is possible to reset, in other words delete, all the programmed cycles entered by the user by holding down the Clock Button in the initial screen for approx. five seconds.
Installation, use and maintenance guide ECOTHERM 5000TCOM 6 – USE OF THE APPLIANCE 6.1 DESCRIPTION OF THE OPERATING STAGES START: has a duration of approx. 20 minutes, during this phase the appliance is programmed to light the flame. The appliance will not accept power variations in the firebox.
Page 17
Installation, use and maintenance guide ECOTHERM 5000TCOM 6.5 FILTER This practical device prevents the circulation of dust which is always present in household environments. The filter is installed on the back of the appliance. Clean frequently to ensure the maximum availability of hot air when the appliance is operating (wash the filter with cold water then dry thoroughly every 5 days).
Page 18
Installation, use and maintenance guide ECOTHERM 5000TCOM If you wish to channel the air with one vent only, then you must partially undo the screw C1 using a suitable screwdriver, remove screws C2, remove the pipe E and replace it with the cover D securing it with the screws C2 just removed.
Chrono function on the panel. In the event of connections to the chrono-thermostat Thermorossi shall not be held responsible for the appliance not starting up, smoke leaks, breakage of the lighting component. The user must make sure that the brazier is always clean.
Installation, use and maintenance guide ECOTHERM 5000TCOM 8 – CLEANING AND MAINTENANCE 8.1 FOREWORD Before commencing any operation disconnect the appliance from the electric power outlet. Your pellet appliance needs maintenance; it requires a few simple, basic but frequent control and general cleaning operations. This will guarantee safe and regular operation and optimal output at all times.
Page 21
Installation, use and maintenance guide ECOTHERM 5000TCOM Page 20...
Page 23
Installation, use and maintenance guide ECOTHERM 5000TCOM 8.3 REPLACING THE BATTERY OF THE CONTROL PANEL Inside the control panel there is a buffer battery type CR1632. When the time and programming are not being memorised, then the battery needs replacing. Proceed as follows: Switch off the appliance and unplug the power cable from the power source.
Installation, use and maintenance guide ECOTHERM 5000TCOM 9 – SMOKE DISCHARGE TUBE AND VENTILATION OF THE ROOMS 9.1 FOREWORD Due to the frequent accidents caused by poor functioning of flue outlets installed in private dwellings, we have prepared the following paragraph to assist the installer in his inspection of the parts concerned with eliminating the gases produced by combustion.
Installation, use and maintenance guide ECOTHERM 5000TCOM 9.3.2 FLUE OUTLET / FLUE SYSTEM COMPONENTS Components and accessories of a Every chimney must have minimum number of chimney components as laid down by standard UNI EN 1443 which are also indicated in the figure on the left.
Page 26
Installation, use and maintenance guide ECOTHERM 5000TCOM It is strictly forbidden to apply mesh to the end of the outlet tube, as it could cause the appliance to malfunction. If the smoke tube is installed in a fixed position it is advisable to provide inspection openings for clean-out purposes especially in the horizontal sections.
ATTENTION: The appearance of one of the alarms described below, does not necessarily imply a defect in the product, but simply Thermorossi S.p.A.’s intention to inform the user of the need for corrective actions in order to guarantee maximum safety, greater reliability and high performance of the appliance.
Installation, use and maintenance guide ECOTHERM 5000TCOM 12 – INFORMATION FOR THE SKILLED TECHNICIAN 12.1 MAIN COMPONENTS AND THEIR OPERATION SMOKE PRESSURE SWITCH This is a safety switch that stops the screw feeder motor whenever necessary. The main cause for the pressure switch tripping is a blocked flue outlet or smoke exhaust pipe.
Installation, use and maintenance guide ECOTHERM 5000TCOM 12.3 TROUBLESHOOTING CAUSE-SOLUTION PROBLEM POSSIBLE CAUSE SOLUTION CLEAN THE BRAZIER AS INDICATED IN THIS USE AND PELLET TANK IS EMPTY MAINTENANCE GUIDE, THEN FILL UP THE TANK WITH THE “NO PELLET – CLEAN BURNER” ALARM IS SHOWN ON THE DISPLAY...
Page 31
Installation, use and maintenance guide ECOTHERM 5000TCOM PROBLEM POSSIBLE CAUSE SOLUTION OCCURS THE FIRST TIME THE APPLIANCE IS SWITCHED ON AS THE SILICONE PAINT IS RUN THE APPLIANCE AT HIGH POWER LEVELS FOR A FEW BEING BAKED DAYS CHECK THE TIGHTNESS OF THE FLUE OUTLET AND IN...